Tyrosinase biosensor for benzoic acid inhibition-based determination with the use of a flow-batch monosegmented sequential injection system.

Amperometric tyrosinase based biosensor for benzoic acid determination with the use of a flow-batch monosegmented sequential injection system is proposed. The functioning of the biosensor is based on the inhibition effect of benzoic acid on the biocatalytic activity of tyrosinase, polyphenol oxidase. In the biosensor, tyrosinase is entrapped in titania gel modified with multiwalled carbon nanotubes (MWCNT) and Nafion. The procedure of optimization of experimental conditions affecting the biosensor response, as well as its analytical characteristics and results of the approach verification using synthetic samples and a reference material are presented. The developed biosensor exhibits linear range up to 2.46μM, good sensitivity toward benzoic acid (1.06μAμM(-1)) and low detection limit (0.03μM). The approach has been applied to benzoic acid determination in a real beverage sample giving the result consistent with that obtained using the HPLC method.

[1]  Chunzhou Dong,et al.  Headspace solid-phase microextraction applied to the simultaneous determination of sorbic and benzoic acids in beverages , 2006 .

[2]  W. Schuhmann,et al.  Reagentless amperometric formaldehyde-selective biosensors based on the recombinant yeast formaldehyde dehydrogenase. , 2008, Talanta.

[3]  S. Brul,et al.  Preservative agents in foods. Mode of action and microbial resistance mechanisms. , 1999, International journal of food microbiology.

[4]  M. T. Sancho,et al.  Simultaneous determination of organic acids in beverages by capillary zone electrophoresis , 2006 .

[5]  P. Solich,et al.  Determination of ambroxol hydrochloride, methylparaben and benzoic acid in pharmaceutical preparations based on sequential injection technique coupled with monolithic column. , 2006, Journal of pharmaceutical and biomedical analysis.

[6]  Wei Hu,et al.  Determination of benzoic acid in soft drinks by gas chromatography with on-line pyrolytic methylation technique , 2005 .

[7]  Valeria A. Lozano,et al.  Simultaneous determination of sorbic and benzoic acids in commercial juices using the PLS-2 multivariate calibration method and validation by high performance liquid chromatography. , 2007, Talanta.

[8]  J. Pingarrón,et al.  Detection of phenolic compounds in flow systems based on tyrosinase-modified reticulated vitreous carbon electrodes. , 2001, Talanta.

[9]  J. Kochana,et al.  Meldola’s Blue — doped titania sol-gel sensor for NADH determination , 2010 .

[10]  P. Kościelniak Nonlinear calibration by the standard addition method , 1999 .

[11]  J. Masini,et al.  Exploiting monosegmented flow analysis to perform in-line standard additions using a single stock standard solution in spectrophotometric sequential injection procedures , 2002 .

[12]  Najma Memon,et al.  Determination of preservatives in cosmetics and food samples by micellar liquid chromatography. , 2005, Journal of separation science.

[13]  Alexey L. Pomerantsev,et al.  Prediction of the aging of polymer materials , 1999 .

[14]  M. Toledo,et al.  Determination of benzoic and sorbic acids in Brazilian food , 2002 .

[15]  C. Pasquini,et al.  Spectrophotometric Determination of Chromium ( VI ) , Ammonia , and Phosphorus , 2022 .

[16]  R. Vaidya,et al.  Use of charged membranes to control interference by body chemicals in a glucose biosensor. , 1994, Medical engineering & physics.

[17]  M. S. López,et al.  Inhibition Biosensor Based on Calcium Phosphate Materials for Detection of Benzoic Acid in Aqueous and Organic Media , 2011 .

[18]  J. Jakmunee,et al.  Simultaneous determination of some food additives in soft drinks and other liquid foods by flow injection on-line dialysis coupled to high performance liquid chromatography. , 2011, Talanta.

[19]  Xinyu Jiang,et al.  Determination of Benzoic Acid in Water Samples by Ionic Liquid Cold-Induced Aggregation Dispersive LLME Coupling with LC , 2010 .

[21]  G. Palleschi,et al.  Enzyme inhibition-based biosensors for food safety and environmental monitoring. , 2006, Biosensors & bioelectronics.

[22]  W. Gan,et al.  Determination of benzoic acid and sorbic acid in food products using electrokinetic flow analysis-ion pair solid phase extraction-capillary zone electrophoresis. , 2008, Analytica chimica acta.

[23]  J. Kochana,et al.  Tyrosinase/laccase bienzyme biosensor for amperometric determination of phenolic compounds , 2008 .

[24]  Peng Wang,et al.  Inhibition of benzoic acid on the polyaniline–polyphenol oxidase biosensor , 2010 .

[25]  J M Pingarrón,et al.  Design of a composite amperometric enzyme electrode for the control of the benzoic acid content in food. , 2002, Talanta.

[26]  H. Goicoechea,et al.  Spectrophotometric determination of sorbic and benzoic acids in fruit juices by a net analyte signal-based method with selection of the wavelength range to avoid non-modelled interferences , 2003, Analytical and bioanalytical chemistry.

[27]  J. Riu,et al.  Electrochemical sensing based on carbon nanotubes , 2010 .

[28]  Alejandro C Olivieri,et al.  New method for the determination of benzoic and sorbic acids in commercial orange juices based on second-order spectrophotometric data generated by a pH gradient flow injection technique. , 2004, Journal of agricultural and food chemistry.

[29]  S. Dong,et al.  Silica sol-gel composite film as an encapsulation matrix for the construction of an amperometric tyrosinase-based biosensor. , 2000, Biosensors & bioelectronics.

[30]  Huaiguo Xue,et al.  Inhibitive detection of benzoic acid using a novel phenols biosensor based on polyaniline-polyacrylonitrile composite matrix. , 2007, Talanta.

[31]  Walter Lund,et al.  The pharmaceutical codex: principles and practice of pharmaceutics. , 1994 .

[32]  J. Kochana,et al.  Titania sol–gel-derived tyrosinase-based amperometric biosensor for determination of phenolic compounds in water samples. Examination of interference effects , 2008, Analytical and bioanalytical chemistry.

[33]  Serge Cosnier,et al.  A highly reversible and sensitive tyrosinase inhibition-based amperometric biosensor for benzoic acid monitoring , 2008 .

[34]  P. Kościelniak,et al.  An automatic system for acidity determination based on sequential injection titration and the monosegmented flow approach. , 2011, Talanta.