Combined Use of Morphology Discrimination, Sudden Onset, and Stability as Discriminating Algorithms in Single Chamber Cardioverter Defibrillators

BORIANI, G., et al.: Combined Use of Morphology Discrimination, Sudden Onset, and Stability as Discriminating Algorithms in Single Chamber Cardioverter Defibrillators. Morphology Discrimination (MD) is a rhythm discriminator based on QRS morphology analysis that can be combined with other discriminators like Stability, with or without Sinus Interval History (SIH) and Sudden Onset. Thirty‐five patients implanted with a St. Jude Medical single chamber ICD were evaluated during exercise testing, during induced AF, and during follow‐up for 14 ± 5 months. At exercise testing (60 episodes detected) MD had a specificity (SP) of 96.7% and Sudden Onset a SP of 91.7%; during induced AF (25 episodes) both MD and Stability had a SP of 96.0%. The diagnostic performance on spontaneous arrhythmias was as follows: for ventricular tachycardia (126 episodes) a sensitivity (SE) of 94.4% for MD, 92.1% for Sudden Onset, 89.7% for Stability without SIH and 79.4% for Stability + SIH; for sinus tachycardia (44 episodes) a SP of 86.4% for MD, 97.7% for Sudden Onset, 2.3% for Stability and of 95.5% for Stability + SIH. For AF (165 cases) a SP of 67.9% for MD, 69.1% for Stability and 90.3% for Stability + SIH, 44.8% for Sudden Onset. Use of MD alone provided a SE of 94.4% and a SP of 71.4% for spontaneous arrhythmias and combined use of the discriminators in a “2 of 3” diagnostic logic implied a SP of 90.9% with maintenance of 96.0% of SE. In single chamber ICDs a wide range of SE/SP ratios may be obtained by use of multiple discriminators, but use of the algorithm in a 2 of 3 diagnostic logic may achieve a SP of 90.9% and a SE of 96.0%.

[1]  D. Zipes Implantable cardioverter-defibrillator: A Volkswagen or a Rolls Royce: how much will we pay to save a life? , 2001, Circulation.

[2]  G. Breithardt,et al.  Efficacy and Safety of the Initial Use of Stability and Onset Criteria in Implantable Cardioverter Defibrillators , 1999, Journal of cardiovascular electrophysiology.

[3]  V. Kühlkamp,et al.  Clinical Experience with the New Detection Algorithms for Atrial Fibrillation of a Defibrillator with Dual Chamber Sensing and Pacing , 1999, Journal of cardiovascular electrophysiology.

[4]  G. Tomaselli,et al.  Morphologic Differences of the Endocardial Electrogram in Beats of Sinus and Ventricular Origin * , 1988, Pacing and clinical electrophysiology : PACE.

[5]  H. Wellens,et al.  Dual Chamber Arrhythmia Detection in the Implantable Cardioverter Defibrillator , 2000, Journal of cardiovascular electrophysiology.

[6]  J M Jenkins,et al.  Impact of Filtering Upon Ventricular Tachycardia Identification by Correlation Waveform Analysis , 1991, Pacing and clinical electrophysiology : PACE.

[7]  M. Achtelik,et al.  Single-chamber versus dual-chamber implantable cardioverter defibrillators: indications and clinical results. , 1999, The American journal of cardiology.

[8]  H. Trappe,et al.  Neues ICD-Morphologie-Kriterium zur Differenzierung supraventrikulärer und ventrikulärer Tachykardien , 2000, Zeitschrift für Kardiologie.

[9]  J M Jenkins,et al.  Real‐Time Arrhythmia Identification from Automated Analysis of Intraatrial and Intraventricular Electrograms , 1993, Pacing and clinical electrophysiology : PACE.

[10]  G. Boriani,et al.  Clinical Evaluation of Morphology Discrimination: An Algorithm for Rhythm Discrimination in Cardioverter Defibrillators , 2001, Pacing and clinical electrophysiology : PACE.

[11]  J M Jenkins,et al.  Intraventricular Electrogram Analysis for Ventricular Tachycardia Detection: Statistical Validation , 1990, Pacing and clinical electrophysiology : PACE.

[12]  M. Schlepper,et al.  Programmable VT Detection Enhancements in Implantable Cardioverter Defibrillator Therapy , 1995, Pacing and clinical electrophysiology : PACE.

[13]  Intracardiac electrogram transformation. Morphometric implications for implantable devices. , 1996, Journal of electrocardiology.

[14]  R. Luceri Initial Clinical Experience with a Dual Chamber Rate Responsive Implantable Cardioverter Defibrillator , 2000, Pacing and clinical electrophysiology : PACE.

[15]  B. KenKnight,et al.  A preview of implantable cardioverter defibrillator systems in the next millennium: an integrative cardiac rhythm management approach. , 1999, The American journal of cardiology.

[16]  C. Schmitt,et al.  Do Current Dual Chamber Cardioverter Defibrillators Have Advantages Over Conventional Single Chamber Cardioverter Defibrillators in Reducing Inappropriate Therapies? A Randomized, Prospective Study , 2001, Journal of cardiovascular electrophysiology.

[17]  J. Brugada,et al.  Enhanced Detection Criteria in Implantable Defibrillators , 1998, Journal of cardiovascular electrophysiology.

[18]  J. Jenkins,et al.  A comparison of four new time-domain techniques for discriminating monomorphic ventricular tachycardia from sinus rhythm using ventricular waveform morphology , 1991, IEEE Transactions on Biomedical Engineering.

[19]  A. Schaumann,et al.  Enhanced detection criteria in implantable cardioverter-defibrillators to avoid inappropriate therapy. , 1996, The American journal of cardiology.

[20]  F. Marchlinski,et al.  Implantation: Pre-operative Evaluation to Discharge , 1996 .

[21]  M. Rahn-Schönbeck,et al.  Morphology Discriminator Feature for Enhanced Ventricular Tachycardia Discrimination in Implantable Cardioverter Defibrillators , 2000, Pacing and clinical electrophysiology : PACE.

[22]  MILTON M. MORRIS,et al.  Band‐Limited Morphometric Analysis of the Intracardiac Signal: Implications for Antitachycardia Devices , 1997, Pacing and clinical electrophysiology : PACE.

[23]  M. Kroll,et al.  Implantable Cardioverter Defibrillator Therapy: The Engineering-Clinical Interface , 2012, Developments in Cardiovascular Medicine.

[24]  S. Higgins,et al.  Stability: An ICD Detection Criterion for Discriminating Atrial Fibrillation From Ventricular Tachycardia , 1995, Journal of cardiovascular electrophysiology.

[25]  M. Borggrefe,et al.  Clinical experience with antitachycardia pacing and improved detection algorithms in a new implantable cardioverter-defibrillator. , 1993, Journal of the American College of Cardiology.