An electrochemical sensor device for measuring blood ammonia at the point of care.

The level of ammonia in blood is relevant in a number of medical conditions. While ammonia is a marker of dysfunction, elevated ammonia is itself a serious medical emergency and can lead to significant and permanent neurological impairment if not addressed quickly. Blood ammonia testing is typically performed in the central laboratory. While a number of point of care devices have been developed, these are based on classical enzymatic or colorimetric principles and have not been widely adopted. In this work, an electrochemical sensor device was developed for measuring blood ammonia. The device was based on the deposition of polyaniline nanoparticle films onto screen printed interdigitated electrodes using inkjet printing and their integration into a polymer microfabricated device with a polytetrafluoroethylene membrane. The device required a 52µL serum sample and measured the change in impedance of the sensor with respect to air at 1kHz, 5mV rms. The device was capable of the measurement of ammonia in serum across the physiologically relevant range of 25-200µM (r2 =0.9984) and had a limit of detection of 12µM (n =3). The device showed no significant issues with common electrochemical interferences in blood. The device was also validated against a commercial spectrophotometric assay which resulted in excellent correlation (r =0.9699, p<0.0001) between both methods (n =3). When stored under desiccation, devices displayed minimal variation over time (0.64%) with respect to their impedance in air (n =12) and could be stored in desiccant for at least five months.

[1]  Karl Crowley,et al.  Point of care monitoring of hemodialysis patients with a breath ammonia measurement device based on printed polyaniline nanoparticle sensors. , 2013, Analytical chemistry.

[2]  Mario Aranda-Bustos,et al.  Development of a bienzymatic amperometric biosensor to determine uric acid in human serum, based on mesoporous silica (MCM-41) for enzyme immobilization , 2014 .

[3]  H. Lenhoff,et al.  Interference in determination of ammonia with the hypochlorite-alkaline phenol method of Berthelot , 1982 .

[4]  Sergey A. Piletsky,et al.  Ammonia sensors based on sensitive polyaniline films , 1996 .

[5]  Aihua Liu,et al.  Amperometric L-glutamate biosensor based on bacterial cell-surface displayed glutamate dehydrogenase. , 2015, Analytica chimica acta.

[6]  Gordon G. Wallace,et al.  Fabrication of an ammonia gas sensor using inkjet-printed polyaniline nanoparticles , 2008 .

[7]  Joseph Wang,et al.  Electrochemical biosensors: towards point-of-care cancer diagnostics. , 2006, Biosensors & bioelectronics.

[8]  S. Nuttall,et al.  The impact of therapeutic doses of paracetamol on serum total antioxidant capacity , 2003, Journal of clinical pharmacy and therapeutics.

[9]  Karl Crowley,et al.  Direct measurement of ammonia in simulated human breath using an inkjet-printed polyaniline nanoparticle sensor. , 2013, Analytica chimica acta.

[10]  Karl Crowley,et al.  An aqueous ammonia sensor based on an inkjet-printed polyaniline nanoparticle-modified electrode. , 2008, The Analyst.

[11]  M. Adeva,et al.  Ammonium metabolism in humans. , 2012, Metabolism: clinical and experimental.

[12]  Anthony Turner,et al.  Biosensors: Sense and Sensibility , 2013 .

[13]  S. Menon,et al.  A simple and rapid creatinine sensing via DLS selectivity, using calix[4]arene thiol functionalized gold nanoparticles. , 2016, Talanta.

[14]  Gordon G Wallace,et al.  Inkjet printable polyaniline nanoformulations. , 2007, Langmuir : the ACS journal of surfaces and colloids.

[15]  A. Morrin,et al.  A sensor probe for the continuous in situ monitoring of ammonia leakage in secondary refrigerant systems , 2013 .

[16]  R. Barsotti Measurement of ammonia in blood. , 2001, The Journal of pediatrics.

[17]  A. Morrin,et al.  Printing polyaniline for sensor applications , 2013, Chemické zvesti.

[18]  Seyeon Park The Effects of High Concentrations of Vitamin C on Cancer Cells , 2013, Nutrients.