A simple and compact parallel robotic wrist for laparoscopy

Current surgical robotic systems tend to be large, cumbersome and difficult to configure for a specific procedure. They use to need a large operation room time consuming. This work presents advances in the development of a prototype of surgical parallel robotic wrist for laparoscopic procedures. This wrist is small, compact and easy to configure. The paper details the mechanical design of the current prototype (version 2), its kinematic analysis and, mainly, it centers on the teleoperation control scheme. The first results of the behavior of the prototype in the operation room are shown. The main features of the parallel wrist are the small dimensions (120×80×80 mm) and weigth (420 gr), its modular design that allows to mount the wrist over the patient and the ability to estimate the forces at the tip of the surgical tool without the need of a force sensor.

[1]  Philippe Cinquin,et al.  Development of miniaturized light endoscope-holder robot for laparoscopic surgery , 2007, Journal of endourology.

[2]  José Maria Azorín,et al.  Magister-P; a 6-URS parallel haptic device with open control architecture , 2005, Robotica.

[3]  Leo Joskowicz,et al.  Bone-mounted miniature robot for surgical procedures: Concept and clinical applications , 2003, IEEE Trans. Robotics Autom..

[4]  Russell H. Taylor,et al.  Medical Robotic Systems in Computer-Integrated Surgery , 2003 .

[5]  Ji Ma,et al.  Task evaluations of a compact laparoscopic surgical robot system , 2007, 2007 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[6]  B. Hannaford,et al.  Surgical robotics : systems, applications and visions , 2011 .

[7]  Klaus Radermacher,et al.  CRIGOS: a compact robot for image-guided orthopedic surgery , 1999, IEEE Transactions on Information Technology in Biomedicine.

[8]  Paolo Dario,et al.  Microrobotics for future gastrointestinal endoscopy , 2007, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[9]  S. Brink-Danan,et al.  Robotic assisted spinal surgery–from concept to clinical practice , 2007, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[10]  Russell H. Taylor,et al.  Medical robotics in computer-integrated surgery , 2003, IEEE Trans. Robotics Autom..

[11]  B. Hannaford,et al.  Doc at a Distance , 2006, IEEE Spectrum.

[12]  Roque Saltaren,et al.  Kinematics of a robotic 3UPS1S spherical wrist designed for laparoscopic applications , 2010, The international journal of medical robotics + computer assisted surgery : MRCAS.

[13]  H. Scharf,et al.  Today's state of the art in surgical robotics , 2005, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[14]  José Maria Azorín,et al.  Performance evaluation of spherical parallel platforms for humanoid robots , 2007, Robotica.

[15]  José Maria Azorín,et al.  Teleoperated parallel climbing robots in nuclear installations , 2006, Ind. Robot.

[16]  Michael D Klein,et al.  Totally minimally invasive robot-assisted unstented pyeloplasty using the Zeus Microwrist Surgical System: an animal study. , 2005, Journal of pediatric surgery.

[17]  L. W. Tsai,et al.  Robot Analysis: The Mechanics of Serial and Parallel Ma-nipulators , 1999 .