DC-Link Stabilization and Voltage Sag Ride-Through of Inverter Drives

Previous results concerning instability of the dc link in inverter drives fed from a dc grid or via a rectifier are extended. It is shown that rectifier-inverter drives equipped with small (film) dc-link capacitors may need active stabilization. The impact of limited bandwidth and switching frequency in the inverter-motor current control loop is considered, and recommendations for selection of the dc-link capacitor, the switching frequency, and the dc-link stabilization control law in relation to each other are given. This control law is incorporated in a field-weakening (to enhance voltage sag ride-through) current controller for which design recommendations are presented

[1]  Hans-Peter Nee,et al.  Model-based current control of AC machines using the internal model control method , 1995 .

[2]  R. J. Kerkman,et al.  Field-oriented control of an induction machine in the field-weakening region with DC-link and load disturbance rejection , 1997 .

[3]  R. Spee,et al.  Voltage sag ride-through for adjustable speed drives with active rectifiers , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[4]  Kai Pietiläinen Voltage sag ride-through control of induction motor drives , 2001 .

[5]  Kurt Stockman,et al.  Torque capability of a field oriented induction motor drive under voltage sag conditions , 2003 .

[6]  Henrik Mosskull Stabilization of an induction machine drive , 2003 .

[7]  Lennart Harnefors,et al.  Torque-maximizing field-weakening control: design, analysis, and parameter selection , 2001, IEEE Trans. Ind. Electron..

[8]  Lennart Harnefors,et al.  Unified sensorless vector control of synchronous and induction motors , 2003, IEEE Trans. Ind. Electron..

[9]  Thomas A. Lipo,et al.  Stability Analysis of a Rectifier-Inverter Induction Motor Drive , 1969 .

[10]  Hans-Peter Nee,et al.  An AC Converter with a Small DC link Capacitor for a 15kW Permanent Magnet Synchronous Integral Motor , 1998 .

[11]  Robert C. Hilborn,et al.  Chaos And Nonlinear Dynamics: An Introduction for Scientists and Engineers , 1994 .

[12]  Tore Undeland,et al.  Power Electronics: Converters, Applications and Design , 1989 .

[13]  Ali Emadi,et al.  Modeling of power electronic loads in AC distribution systems using the generalized State-space averaging method , 2004, IEEE Transactions on Industrial Electronics.

[14]  A. M. Walczyna,et al.  Input filter stability of drives fed from voltage inverters controlled by direct flux and torque control methods , 1996 .