Intensity modulated arc deliveries approximated by a large number of fixed gantry position sliding window dynamic multileaf collimator fields.

The intensity modulated arc has been proposed as an alternative to tomotherapy. Treatment planing systems more typically model the conventional step and shoot or sliding window dynamic multileaf collimator (DMLC) deliveries, and may not support intensity modulated arc therapy (IMAT). As well, another potential drawback to this technique is that increasing the number of intensity levels required to achieve certain dose distributions necessitates increasing the number of gantry passes, as may occur if the desired dose distribution is complex (e.g., concave or bifurcated), potentially increasing the overall treatment time. A technique is presented here for the delivery of tomotherapy like dose distributions in a single gantry pass by the use of a large number of fields modulated by a sliding window DMLC technique from fixed equally spaced gantry positions. This serves as a good approximation to either IMAT or tomotherapy deliveries. The planning of these fields is achieved using iterative filtered back projection. Measured results of deliveries of varying degrees of complexity on a homogeneous phantom are compared to desired distributions.

[1]  D W Anderson,et al.  Comparison of film and ion chamber systems for depth-dose measurements for a 25 MV beam. , 1979, Physics in medicine and biology.

[2]  S C Sharma,et al.  Film dosimetry of megavoltage photon beams: a practical method of isodensity-to-isodose curve conversion. , 1981, Medical physics.

[3]  John F. Canny,et al.  A Computational Approach to Edge Detection , 1986, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[4]  A L Boyer,et al.  Investigation of an FFT-based correlation technique for verification of radiation treatment setup. , 1991, Medical physics.

[5]  G. Barnea,et al.  Measurement of the source size of a 6- and 18-MV radiotherapy linac. , 1992, Medical physics.

[6]  R. Urtasun,et al.  Does improved depth dose characteristics and treatment planning correlate with a gain in therapeutic results? Evidence from past clinical experience using conventional radiation sources. , 1992, International journal of radiation oncology, biology, physics.

[7]  D. Convery,et al.  The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation , 1992 .

[8]  T Knöös,et al.  Application of the convolution method for calculation of output factors for therapy photon beams. , 1992, Medical physics.

[9]  A Fenster,et al.  X-ray sources of medical linear accelerators: focal and extra-focal radiation. , 1993, Medical physics.

[10]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[11]  J J Battista,et al.  Dose calculations using convolution and superposition principles: the orientation of dose spread kernels in divergent x-ray beams. , 1993, Medical physics.

[12]  S. Spirou,et al.  Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators. , 1994, Medical physics.

[13]  T. Holmes,et al.  A filtered backprojection dose calculation method for inverse treatment planning. , 1994, Medical physics.

[14]  W Schlegel,et al.  Dynamic X-ray compensation for conformal radiotherapy by means of multi-leaf collimation. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  R Svensson,et al.  An analytical solution for the dynamic control of multileaf collimators. , 1994, Physics in medicine and biology.

[16]  P. Shragge,et al.  Calibration of film for accurate megavoltage photon dosimetry. , 1994, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[17]  R. Sloboda,et al.  Analytical representation of head scatter factors for shaped photon beams using a two-component x-ray source model. , 1995, Medical physics.

[18]  Cedric X. Yu,et al.  Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy. , 1995, Physics in medicine and biology.

[19]  C. Yu,et al.  A method for implementing dynamic photon beam intensity modulation using independent jaws and a multileaf collimator. , 1995, Physics in medicine and biology.

[20]  P. Harari,et al.  Advances in radiation therapy for head and neck cancer , 1995, Current opinion in oncology.

[21]  D. Low,et al.  Feasibility study of multileaf collimated electrons with a scattering foil based accelerator. , 1996, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[22]  C De Wagter,et al.  Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: static beam-segmentation technique executed with a multileaf collimator. , 1996, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[23]  B. Zackrisson,et al.  Matching of electron beams for conformal therapy of target volumes at moderate depths. , 1996, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[24]  K L Lam,et al.  Flattening-filter-based empirical methods to parametrize the head scatter factor. , 1996, Medical physics.

[25]  M. Martel,et al.  Parotid gland sparing in patients undergoing bilateral head and neck irradiation: techniques and early results. , 1996, International journal of radiation oncology, biology, physics.

[26]  J M Wilkinson,et al.  Head scatter modelling for irregular field shaping and beam intensity modulation. , 1997, Physics in medicine and biology.

[27]  P M Evans,et al.  Dosimetric evaluation of compensation in radiotherapy of the breast: MLC intensity modulation and physical compensators. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[28]  T. Mackie,et al.  A dual source photon beam model used in convolution/superposition dose calculations for clinical megavoltage x-ray beams. , 1997, Medical physics.

[29]  A L Boyer,et al.  Modulated beam conformal therapy for head and neck tumors. , 1997, International journal of radiation oncology, biology, physics.

[30]  B. Paliwal,et al.  Analysis and convergence of the iterative convolution/superposition dose reconstruction technique for multiple treatment beams and tomotherapy. , 1997, Medical physics.

[31]  T R Mackie,et al.  Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model. , 1997, Medical physics.

[32]  S Mutic,et al.  Abutment region dosimetry for sequential arc IMRT delivery. , 1997, Physics in medicine and biology.

[33]  M. Martel,et al.  Comprehensive irradiation of head and neck cancer using conformal multisegmental fields: assessment of target coverage and noninvolved tissue sparing. , 1998, International journal of radiation oncology, biology, physics.

[34]  M Zaider,et al.  A little to a lot or a lot to a little: is NTCP always minimized in multiport therapy? , 1998, International journal of radiation oncology, biology, physics.

[35]  E. Klein Modulated electron beams using multi-segmented multileaf collimation. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[36]  T. Mackie,et al.  Megavoltage CT on a tomotherapy system. , 1999, Physics in medicine and biology.

[37]  K. Ruchala,et al.  Image/patient registration from (partial) projection data by the Fourier phase matching method. , 1999, Physics in medicine and biology.

[38]  C. Langer,et al.  Concurrent chemoradiation using paclitaxel and carboplatin in locally advanced non-small cell lung cancer. , 1999, Seminars in radiation oncology.

[39]  T R Mackie,et al.  Registration using tomographic projection files. , 1999, Physics in medicine and biology.

[40]  R K Ten Haken,et al.  Dose, volume, and function relationships in parotid salivary glands following conformal and intensity-modulated irradiation of head and neck cancer. , 1999, International journal of radiation oncology, biology, physics.

[41]  Gustavo H. Olivera,et al.  SIX PARAMETER PATIENT REGISTRATION DIRECTLY FROM PROJECTION DATA , 1999 .

[42]  J. Kapatoes,et al.  Megavoltage CT image reconstruction during tomotherapy treatments. , 2000, Physics in medicine and biology.

[43]  G H Olivera,et al.  Calibration of a tomotherapeutic MVCT system. , 2000, Physics in medicine and biology.

[44]  S Webb,et al.  Intensity modulated arc therapy (IMAT) with centrally blocked rotational fields. , 2000, Physics in Medicine and Biology.

[45]  P J Reckwerdt,et al.  Megavoltage CT imaging as a by-product of multileaf collimator leakage. , 2000, Physics in medicine and biology.

[46]  T R Mackie,et al.  A feasible method for clinical delivery verification and dose reconstruction in tomotherapy. , 2001, Medical physics.

[47]  J. Kapatoes,et al.  On the accuracy and effectiveness of dose reconstruction for tomotherapy. , 2001, Physics in medicine and biology.

[48]  J C Rosenwald,et al.  Variation of sensitometric curves of radiographic films in high energy photon beams. , 2001, Medical physics.

[49]  B. Fallone,et al.  Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system , 2002, Journal of applied clinical medical physics.