Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar Reconstruction

Background—We analyzed the accuracy of multi-detector row spiral computed tomography (MDCT) using a 16-slice CT scanner with improved spatial and temporal resolution, as well as routine premedication with &bgr;-blockers for detection of coronary stenoses. Methods and Results—Seventy-seven patients with suspected coronary disease were studied by MDCT (12×0.75-mm cross-sections, 420 ms rotation, 100 mL contrast agent IV at 5 mL/s). Patients with a heart rate above 60/min received 50 mg atenolol before the scan. In axial MDCT images and multiplanar reconstructions, all coronary arteries and side branches with a diameter of 1.5 mm or more were assessed for the presence of stenoses exceeding 50% diameter reduction. In comparison to invasive coronary angiography, MDCT correctly classified 35 of 41 patients (85%) as having at least 1 coronary stenosis and correctly detected 57 of 78 coronary lesions (73%). After excluding 38 of 308 coronary arteries (left main, left anterior descending, left circumflex, and right coronary artery in 77 patients) classified as unevaluable by MDCT (12%), 57 of 62 lesions were detected, and absence of stenosis was correctly identified in 194 of 208 arteries (sensitivity: 92%; specificity: 93%; accuracy: 93%; positive and negative predictive values: 79% and 97%). Conclusions—MDCT coronary angiography with improved spatial resolution and premedication with oral &bgr;-blockade permits detection of coronary artery stenoses with high accuracy and a low rate of unevaluable arteries.

[1]  A. Kopp,et al.  Darstellung der Herzkranzgefäße im CT mittels neuer 16-Zeilen-Technologie und reduzierter Rotationszeit: Erste Erfahrungen , 2002 .

[2]  Pedro A. Lemos,et al.  Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed Tomography , 2002, Circulation.

[3]  R. Frye,et al.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. , 1975, Circulation.

[4]  Matthijs Oudkerk,et al.  Coronary angiography with multi-slice computed tomography , 2001, The Lancet.

[5]  J. Rumberger,et al.  Noninvasive coronary angiography using computed tomography: ready to kick it up another notch? , 2002, Circulation.

[6]  E. Wenkel,et al.  Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection. , 2002, AJR. American journal of roentgenology.

[7]  C. White,et al.  Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses. , 2001, The American journal of cardiology.

[8]  J Simon,et al.  New Technical Developments in Multislice CT, Part 2: Sub-Millimeter 16-Slice Scanning and Increased Gantry Rotation Speed for Cardiac Imaging , 2002, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[9]  C. Claussen,et al.  Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients. , 2002, European heart journal.

[10]  Werner Moshage,et al.  Detection of Coronary Artery Stenoses by Contrast-Enhanced, Retrospectively Electrocardiographically-Gated, Multislice Spiral Computed Tomography , 2001, Circulation.

[11]  Thomas Flohr,et al.  Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation , 2002, European Radiology.

[12]  C. Claussen,et al.  [Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time: first experiences]. , 2002, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[13]  K. Engelmann,et al.  Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. , 2002, Radiology.

[14]  C. Claussen,et al.  Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography: experience in 94 patients. , 2002, Clinical imaging.