Variable evaporating temperature control strategy for VRV system under part load conditions in cooling mode

Abstract Control strategy is key technology for efficient and reliable operation of air conditioning system. Although VRV research is booming in recent years, the general control strategy of VRV system is still to regulate refrigerant flow rate while keeping evaporating temperature or discharge pressure constant during cooling or heating process. In this paper, a novel control strategy with variable evaporating temperature is explored under part load conditions. Based on running point determined by original control strategy, the new strategy further reduces running frequency under the same part load conditions. Correspondingly, energy consumption reduces and evaporating temperature rises. Theoretical analysis proves its feasibility of energy saving. Further experimental results show that the novel control strategy would help to improve VRV system energy efficiency and reduce cooling energy consumption especially for part load conditions lower than 50%.

[1]  Tolga N. Aynur,et al.  Variable refrigerant flow systems: A review , 2010 .

[2]  Reinhard Radermacher,et al.  Field performance measurements of a heat pump desiccant unit in dehumidification mode , 2008 .

[3]  Chen Wu,et al.  Development of control method and dynamic model for multi-evaporator air conditioners (MEAC) , 2005 .

[4]  Shoubo Mao,et al.  Heating control strategy in fresh air processor matched with variable refrigerant flow air conditioning system , 2011 .

[5]  Ruzhu Wang,et al.  Energy simulation in the variable refrigerant flow air-conditioning system under cooling conditions , 2007 .

[6]  T.-J. Yeh,et al.  Control of multi-evaporator air-conditioning systems for flow distribution , 2009 .

[7]  Dongliang Zhang,et al.  Study on energy saving possibility of digital variable multiple air conditioning system in three office buildings in Shanghai , 2014 .

[8]  Tainzhen Hong,et al.  Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems , 2009 .

[9]  Yue Ming Li,et al.  Energy simulation and analysis of the heat recovery variable refrigerant flow system in winter , 2010 .

[10]  Xing Fang,et al.  Optimal control of combined air conditioning system with variable refrigerant flow and variable air volume for energy saving , 2014 .

[11]  Shuangquan Shao,et al.  Dynamic simulation of multi-unit air conditioners based on two-phase fluid network model , 2012 .

[12]  Ruzhu Wang,et al.  Simulation and experimental validation of the variable-refrigerant-volume (VRV) air-conditioning system in EnergyPlus , 2008 .

[13]  Zhimin Du,et al.  Generic simulation model of multi-evaporator variable refrigerant flow air conditioning system for control analysis , 2013 .

[14]  Reinhard Radermacher,et al.  Integration of variable refrigerant flow and heat pump desiccant systems for the heating season , 2010 .

[15]  Andrew G. Alleyne,et al.  Partially decentralized control of large-scale variable-refrigerant-flow systems in buildings , 2014 .

[16]  Xu Zhang,et al.  Experimental study of performance of digital variable multiple air conditioning system under part load conditions , 2011 .

[17]  Rui Xiao,et al.  Heating control strategy for variable refrigerant flow air conditioning system with multi-module outdoor units , 2010 .

[18]  Reinhard Radermacher,et al.  Field performance measurements of a heat pump desiccant unit in heating and humidification mode , 2010 .

[19]  Reinhard Radermacher,et al.  Integration of variable refrigerant flow and heat pump desiccant systems for the cooling season , 2010 .

[20]  Reinhard Radermacher,et al.  Field performance measurements of a VRF system with sub-cooler in educational offices for the cooling season , 2012 .

[21]  Chan Mingyin,et al.  Experimental study of a novel capacity control algorithm for a multi-evaporator air conditioning system , 2013 .

[22]  Y. Hwang,et al.  Simulation comparison of VAV and VRF air conditioning systems in an existing building for the cooling season , 2009 .

[23]  Hoon Kang,et al.  Performance characteristics of a simultaneous cooling and heating multi-heat pump at partial load conditions , 2011 .

[24]  Yunho Hwang,et al.  FIELD PERFORMANCE MEASUREMENTS OF A VRV AC/HP SYSTEM , 2006 .