Pros and Cons of 3D Image Fusion in Endovascular Aortic Repair: A Systematic Review and Meta-analysis

Purpose: To systematically review and meta-analyze the added value of 3-dimensional (3D) image fusion technology in endovascular aortic repair for its potential to reduce contrast media volume, radiation dose, procedure time, and fluoroscopy time. Methods: Electronic databases were systematically searched for studies published between January 2010 and March 2016 that included a control group describing 3D fusion imaging in endovascular aortic procedures. Two independent reviewers assessed the methodological quality of the included studies and extracted data on iodinated contrast volume, radiation dose, procedure time, and fluoroscopy time. The contrast use for standard and complex endovascular aortic repairs (fenestrated, branched, and chimney) were pooled using a random-effects model; outcomes are reported as the mean difference with 95% confidence intervals (CIs). Results: Seven studies, 5 retrospective and 2 prospective, involving 921 patients were selected for analysis. The methodological quality of the studies was moderate (median 17, range 15–18). The use of fusion imaging led to an estimated mean reduction in iodinated contrast of 40.1 mL (95% CI 16.4 to 63.7, p=0.002) for standard procedures and a mean 70.7 mL (95% CI 44.8 to 96.6, p<0.001) for complex repairs. Secondary outcome measures were not pooled because of potential bias in nonrandomized data, but radiation doses, procedure times, and fluoroscopy times were lower, although not always significantly, in the fusion group in 6 of the 7 studies. Conclusion: Compared with the control group, 3D fusion imaging is associated with a significant reduction in the volume of contrast employed for standard and complex endovascular aortic procedures, which can be particularly important in patients with renal failure. Radiation doses, procedure times, and fluoroscopy times were reduced when 3D fusion was used.

[1]  Håkan Roos,et al.  EVAR Guided by 3 D Image Fusion and CO 2 DSA : A New Imaging Combination for Patients With Renal Insufficiency , 2015 .

[2]  R. Dhillon,et al.  Predictors of creatinine rise post‐endovascular abdominal aortic aneurysm repair , 2011, ANZ journal of surgery.

[3]  Blandine Maurel,et al.  Evaluation of Visceral Artery Displacement by Endograft Delivery System Insertion , 2014, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[4]  HichamKobeiter,et al.  Zero-Contrast Thoracic Endovascular Aortic Repair Using Image Fusion , 2011 .

[5]  M. Midulla,et al.  Impact of hybrid rooms with image fusion on radiation exposure during endovascular aortic repair. , 2014, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[6]  P Haigron,et al.  Safety and accuracy of endovascular aneurysm repair without pre-operative and intra-operative contrast agent. , 2015, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[7]  Pascal Desgranges,et al.  Image fusion for hybrid repair of dislocated superior mesenteric branch of a branched endovascular aortic graft. , 2013, Journal of vascular surgery.

[8]  M. Gawenda,et al.  Endovascular Aortoiliac Aneurysm Repair with Fenestrated Stent Graft and Iliac Side Branch Using Image Fusion without Iodinated Contrast Medium. , 2016, Annals of vascular surgery.

[9]  Richard Solomon,et al.  Contrast Media and Nephropathy: Findings From Systematic Analysis and Food and Drug Administration Reports of Adverse Effects , 2006, Investigative radiology.

[10]  Jean Marzelle,et al.  Feasibility of Three-Dimensional MR Angiography Image Fusion Guidance for Endovascular Abdominal Aortic Aneurysm Repair. , 2016, Journal of vascular and interventional radiology : JVIR.

[11]  T. Huber,et al.  Three-dimensional fusion computed tomography decreases radiation exposure, procedure time, and contrast use during fenestrated endovascular aortic repair. , 2015, Journal of vascular surgery.

[12]  Pascal Haigron,et al.  Interest of fusion imaging and modern navigation tools with hybrid rooms in endovascular aortic procedures. , 2017, The Journal of cardiovascular surgery.

[13]  J. Angle Cone-beam CT: vascular applications. , 2013, Techniques in vascular and interventional radiology.

[14]  J. C. van den Berg Update on New Tools for Three-dimensional Navigation in Endovascular Procedures , 2014, AORTA.

[15]  Sheng Xu,et al.  Image fusion during vascular and nonvascular image-guided procedures. , 2013, Techniques in vascular and interventional radiology.

[16]  D. Böckler,et al.  Feasibility and accuracy of fusion imaging during thoracic endovascular aortic repair. , 2016, Journal of vascular surgery.

[17]  Atul Gupta,et al.  Live MR angiographic roadmapping for uterine artery embolization: a feasibility study. , 2013, Journal of vascular and interventional radiology : JVIR.

[18]  Dittmar Böckler,et al.  Fusion Imaging to Support Endovascular Aneurysm Repair Using 3D-3D Registration , 2016, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[19]  C. Bartolozzi,et al.  Image Fusion of Preprocedural CTA with Real-time Fluoroscopy to Guide Proper Hepatic Artery Catheterization During Transarterial Chemoembolization of Hepatocellular Carcinoma: A Feasibility Study , 2013, CardioVascular and Interventional Radiology.

[20]  M. Midulla,et al.  Evaluation of radiation during EVAR performed on a mobile C-arm. , 2012, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[21]  G W H Schurink,et al.  CTA with fluoroscopy image fusion guidance in endovascular complex aortic aneurysm repair. , 2014, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[22]  Bradford J. Wood,et al.  Multimodality Image Fusion–Guided Procedures: Technique, Accuracy, and Applications , 2012, CardioVascular and Interventional Radiology.

[23]  S. Munich,et al.  "Contrast-less" stent-assisted coiling of an A1 aneurysm. , 2014, Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association.

[24]  F. Veith,et al.  Use of preoperative magnetic resonance angiography and the Artis zeego fusion program to minimize contrast during endovascular repair of an iliac artery aneurysm. , 2014, Annals of Vascular Surgery.

[25]  Bart Carelsen,et al.  A novel tool for three-dimensional roadmapping reduces radiation exposure and contrast agent dose in complex endovascular interventions. , 2015, Journal of vascular surgery.

[26]  J. Wildberger,et al.  Fusion Guidance in Endovascular Peripheral Artery Interventions: A Feasibility Study , 2014, CardioVascular and Interventional Radiology.

[27]  S. Duman,et al.  The incidence of contrast medium-induced nephropathy following endovascular aortic aneurysm repair: assessment of risk factors , 2015, Japanese Journal of Radiology.

[28]  Update on New Tools for Three-dimensional Navigation in Endovascular Procedures. , 2014 .

[29]  Patrick Gilbert,et al.  Source of errors and accuracy of a two-dimensional/three-dimensional fusion road map for endovascular aneurysm repair of abdominal aortic aneurysm. , 2015, Journal of vascular and interventional radiology : JVIR.

[30]  B. Sonesson,et al.  The effects of combining fusion imaging, low-frequency pulsed fluoroscopy, and low-concentration contrast agent during endovascular aneurysm repair. , 2016, Journal of vascular surgery.

[31]  H. Kurobe,et al.  Contrast Medium Induced Nephropathy after Endovascular Stent Graft Placement: An Examination of Its Prevalence and Risk Factors , 2016, Radiology research and practice.

[32]  Jean Bismuth,et al.  Value of C-Arm Cone Beam Computed Tomography Image Fusion in Maximizing the Versatility of Endovascular Robotics. , 2016, Annals of vascular surgery.

[33]  Håkan Roos,et al.  EVAR Guided by 3D Image Fusion and CO2 DSA , 2015, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[34]  K. Slim,et al.  Methodological index for non‐randomized studies (MINORS): development and validation of a new instrument , 2003, ANZ journal of surgery.

[35]  G. Piffaretti,et al.  Fusion of CT Angiography or MR Angiography with Unenhanced CBCT and Fluoroscopy Guidance in Endovascular Treatments of Aorto-Iliac Steno-Occlusion: Technical Note on a Preliminary Experience , 2015, CardioVascular and Interventional Radiology.

[36]  T. Gleeson,et al.  Contrast-induced nephropathy. , 2004, AJR. American journal of roentgenology.

[37]  Pascal Haigron,et al.  Endovascular aortic repair of a postdissecting thoracoabdominal aneurysm using intraoperative fusion imaging. , 2013, Journal of vascular surgery.

[38]  Y. Morita,et al.  Evaluation of automated 2D-3D image overlay system utilizing subtraction of bone marrow image for EVAR: feasibility study. , 2013, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[39]  A. Luciani,et al.  Image guidance for endovascular repair of complex aortic aneurysms: comparison of two-dimensional and three-dimensional angiography and image fusion. , 2013, Journal of vascular and interventional radiology : JVIR.

[40]  Drazenko Babic,et al.  Fused magnetic resonance angiography and 2D fluoroscopic visualization for endovascular intracranial neuronavigation. , 2013, Journal of neurosurgery.

[41]  M. Dijkstra,et al.  Intraoperative C-arm cone-beam computed tomography in fenestrated/branched aortic endografting. , 2011, Journal of vascular surgery.