Improved power transformer winding fault detection using FRA diagnostics – part 1: axial displacement simulation

Frequency response analysis (FRA) has become a widely accepted tool to detect power transformer winding deformation due to the development of FRA test equipment. Because FRA relies on graphical analysis, interpretation of its signature is a very specialized area that calls for skilled personnel, as so far, there is no reliable standard code for FRA signature identification and quantification. Many researchers investigated the impact of various mechanical winding deformations on the transformer FRA signature using simulation analysis by altering particular electrical parameters of the transformer equivalent electrical circuit. None of them however, investigated the impact of various physical fault levels on the corresponding change in the equivalent circuit parameters. In this paper, the physical geometrical dimension of a single-phase transformer is simulated using 3D finite element analysis to emulate the real transformer operation. A physical axial displacement of different fault levels is simulated in both low voltage and high voltage windings. The impact of each fault level on the electrical parameters of the equivalent circuit is investigated. A key contribution of this paper is the charts it introduces to correlate various axial displacement levels with the percentage change of all transformer equivalent circuit parameters due to the axial displacement fault. In contrary with other researchers who only considered mutual inductance between low voltage and high voltage windings, simulation results shown in this paper reveal that other circuit parameters should be changed by a particular percentage to accurately simulate particular fault level of transformer winding axial displacement. Results of this paper aid to precisely simulating winding axial displacement using transformer equivalent circuit that facilitates accurate qualitative and quantitative analysis of transformer FRA signatures.

[1]  S.M. Gubanski,et al.  Multiscale Computations of Parameters of Power Transformer Windings at High Frequencies. Part I: Small-Scale Level , 2007, IEEE Transactions on Magnetics.

[2]  K. Feser,et al.  Procedures for detecting winding displacements in power transformers by the transfer function method , 2004, IEEE Transactions on Power Delivery.

[3]  L. Satish,et al.  Construction of Equivalent Circuit of a Single and Isolated Transformer Winding From FRA Data Using the ABC Algorithm , 2012, IEEE Transactions on Power Delivery.

[4]  A. Abu-Siada,et al.  A Novel Online Technique to Detect Power Transformer Winding Faults , 2012, IEEE Transactions on Power Delivery.

[5]  Tang Renyuan,et al.  Transient simulation of power transformers using 3D finite element model coupled to electric circuit equations , 2000 .

[6]  M. A. S. Masoum,et al.  Three-Phase Asymmetric Transformer Aging Considering Voltage-Current Harmonic Interactions, Unbalanced Nonlinear Loading, Magnetic Couplings, and Hysteresis , 2012, IEEE Transactions on Energy Conversion.

[7]  Sang-Yong Jung,et al.  Finite-Element Analysis of Short-Circuit Electromagnetic Force in Power Transformer , 2011, IEEE Transactions on Industry Applications.

[8]  M.F. Cabanas,et al.  A New Online Method Based on Leakage Flux Analysis for the Early Detection and Location of Insulating Failures in Power Transformers: Application to Remote Condition Monitoring , 2007, IEEE Transactions on Power Delivery.

[9]  Paul S Moses,et al.  Dynamic Modeling of Three-Phase Asymmetric Power Transformers With Magnetic Hysteresis: No-Load and Inrush Conditions , 2010, IEEE Transactions on Energy Conversion.

[10]  W. Marsden I and J , 2012 .

[11]  Ahmed Abu-Siada,et al.  Frequency Response Analysis Using High Frequency Transformer Model , 2009 .

[12]  Tang Renyuan,et al.  Numerical calculation of 3D eddy current field and short circuit electromagnetic force in large transformers , 1992 .

[13]  A. Abu-Siada,et al.  Understanding power transformer frequency response analysis signatures , 2013, IEEE Electrical Insulation Magazine.

[14]  M. Arshad,et al.  Power transformer asset management , 2004, 2004 International Conference on Power System Technology, 2004. PowerCon 2004..

[15]  S. Liu,et al.  Finite-element-based nonlinear physical model of iron-core transformers for dynamic simulations , 2006, IEEE Transactions on Magnetics.

[16]  Stefan Tenbohlen,et al.  Mathematical Comparison Methods to Assess Transfer Functions of Transformers to Detect Different Types of Mechanical Faults , 2010, IEEE Transactions on Power Delivery.

[17]  L. Satish,et al.  An effort to understand what factors affect the transfer function of a two-winding transformer , 2005, IEEE Transactions on Power Delivery.

[18]  Pradeep M. Nirgude,et al.  Application of numerical evaluation techniques for interpreting frequency response measurements in power transformers , 2008 .

[19]  M. P. Papadopoulos,et al.  Leakage flux and force calculation on power transformer windings under short-circuit: 2D and 3D models based on the theory of images and the finite element method compared to measurements , 1994 .

[20]  PooGyeon Park,et al.  Fault diagnosis of a power transformer using an improved frequency-response analysis , 2005 .

[21]  A A Reykherdt,et al.  Case studies of factors influencing frequency response analysis measurements and power transformer diagnostics , 2011, IEEE Electrical Insulation Magazine.

[22]  Z.D. Wang,et al.  Winding movement in power transformers: a comparison of FRA measurement connection methods , 2006, IEEE Transactions on Dielectrics and Electrical Insulation.

[23]  S. D. Mitchell,et al.  Modeling Power Transformers to Support the Interpretation of Frequency-Response Analysis , 2011, IEEE Transactions on Power Delivery.

[24]  D. J. Wilcox,et al.  Calculation of self and mutual impedances between sections of transformer windings , 1989 .

[25]  T.R. Blackburn A review of Australian research activity in HV insulation and insulation diagnostics , 2005, Proceedings of 2005 International Symposium on Electrical Insulating Materials, 2005. (ISEIM 2005)..

[26]  S. Liu,et al.  FE-Based Modeling of Single-Phase Distribution Transformers With Winding Short Circuit Faults , 2006, IEEE Transactions on Magnetics.

[27]  S.M. Islam,et al.  Power transformer critical diagnostics for reliability and life extension , 2004, Canadian Conference on Electrical and Computer Engineering 2004 (IEEE Cat. No.04CH37513).

[28]  S.A. Ryder Transformer diagnosis using frequency response analysis: results from fault simulations , 2002, IEEE Power Engineering Society Summer Meeting,.

[29]  M. F. Beavers,et al.  The Calculation and Measurement of Axial Electromagnetic Forces on Concentric Coils in Transformers , 1959, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[30]  K. Feser,et al.  Transfer Function Method to Diagnose Axial Displacement and Radial Deformation of Transformer Winding , 2002, IEEE Power Engineering Review.

[31]  A.J. Vandermaar,et al.  Improved detection of power transformer winding movement by extending the FRA high frequency range , 2005, IEEE Transactions on Power Delivery.

[32]  E. Billig,et al.  Mechanical stresses in transformer windings , 1946 .

[33]  S.M. Islam,et al.  Power transformer aging and life extension , 2005, 2004 International Conference on Probabilistic Methods Applied to Power Systems.

[34]  Sung-Chin Hahn,et al.  Experimental Verification and Finite Element Analysis of Short-Circuit Electromagnetic Force for Dry-Type Transformer , 2012, IEEE Transactions on Magnetics.

[35]  Mehdi Vakilian,et al.  Transformer winding faults classification based on transfer function analysis by support vector machine , 2012 .