Efficacy of oxidized regenerated cellulose combined with fibrin glue in reducing pulmonary air leakage after segmentectomy in a porcine lung model

Objectives: Pulmonary air leakage is a common complication following lung resection. We have designed a new method combining oxidized regenerated cellulose and fibrin glue to cover the intersegmental plane in clinical lung segmentectomy to prevent postoperative air leakage. In this study, an excised porcine lung segmentectomy model was created to validate its adhesive strength and effect on reducing air leakage. Methods: In the pre-experiment, six different larger lung segments were separated using electrocautery on the fresh isolated porcine lungs (n = 5 in each group). The air leakage degree and operation time of the lung segments were comprehensively evaluated to select the most suitable target segment for establishing the ex vivo porcine lung segmentectomy models. In the experiment, according to the different materials covered on the intersegmental plane, these models were randomly divided into four groups: group A used fibrin glue and oxidized regenerated cellulose (ORC) mesh (n = 20); group B used fibrin glue and polyglycolic acid (PGA) sheet (n = 20); group C used fibrin glue (n = 20); group D was the blank control group (n = 20). The minimum air leakage pressure (MALP) of the selected target segment in each group was measured using a stepwise increase of airway pressure, and histological assessment was performed on the sealed area samples from the four groups. Results: The operation time of the a segment of the right cranial lobe (R1a) was shorter than that of other segments (p < 0.05), and there was no significant difference in the air leakage pressures between the six isolated segments (p = 0.76); thus, R1a was chosen for segmentectomy. In addition, the MALP was significantly higher in group A (41.8 ± 4.5 cmH2O) than in groups C (28.1 ± 2.3 cmH2O) and D (17.3 ± 1.2 cmH2O) (both p < 0.001). The MALP of group B (69.5 ± 5.2 cmH2O) was significantly higher than that of group A (p < 0.001), whereas that of group C was significantly higher than that of group D (p < 0.001). Histological examination confirmed that the combined use of fibrin glue and ORC or PGA patch adhered more firmly to the intersegmental plane than that of fibrin glue alone, although some gaps could be seen between the fibrin glue and the surface of the lung segments in group C. Conclusion: The application of ORC combined with fibrin glue on the intersegmental plane has a good sealing performance in the ex vivo porcine lung segmentectomy model, suggesting that ORC may be an effective alternative material to replace PGA sheet to combine with fibrin glue for preventing air leakage after segmentectomy.

[1]  Kenji Suzuki,et al.  Segmentectomy versus lobectomy in small-sized peripheral non-small-cell lung cancer (JCOG0802/WJOG4607L): a multicentre, open-label, phase 3, randomised, controlled, non-inferiority trial , 2022, The Lancet.

[2]  H. Igai,et al.  Comparison of stapler and electrocautery for division of the intersegmental plane in lung segmentectomy , 2021, Journal of thoracic disease.

[3]  Oguz Sogut,et al.  A review on synthesis and biomedical applications of polyglycolic acid , 2020, Journal of Polymer Research.

[4]  N. Matsutani,et al.  Long-term effects of pleural defect repair using sheet materials in a canine model , 2019, General Thoracic and Cardiovascular Surgery.

[5]  Kenji Suzuki,et al.  Comparison of pulmonary segmentectomy and lobectomy: Safety results of a randomized trial. , 2019, The Journal of thoracic and cardiovascular surgery.

[6]  S. Yamanaka,et al.  A novel dual-covering method in video-assisted thoracic surgery for pediatric primary spontaneous pneumothorax , 2019, Surgery Today.

[7]  H. Rasouli,et al.  SURGICEL compared with simple gauze packing in grade IV liver injury: an experimental study , 2019, Comparative Clinical Pathology.

[8]  K. Hamano,et al.  Use of Stitching and Bioabsorbable Mesh and Glue to Combat Prolonged Air Leaks. , 2018, The Annals of thoracic surgery.

[9]  Yuki Ozamoto,et al.  Reduction of Pulmonary Air Leaks with a Combination of Polyglycolic Acid Sheet and Alginate Gel in Rats , 2018, BioMed research international.

[10]  Kazuhisa Takahashi,et al.  Oxidized regenerated cellulose induces pleural thickening in patients with pneumothorax: possible involvement of the mesothelial–mesenchymal transition , 2018, Surgery Today.

[11]  S. Motoyama,et al.  Management of Intersegmental Plane on Pulmonary Segmentectomy Concerning Postoperative Complications. , 2017, The Annals of thoracic surgery.

[12]  H. Kataoka,et al.  A Total Pleural Covering for Lymphangioleiomyomatosis Prevents Pneumothorax Recurrence , 2016, PloS one.

[13]  L. Meckley,et al.  Variation in hospital resource use and cost among surgical procedures using topical absorbable hemostats , 2015, ClinicoEconomics and outcomes research : CEOR.

[14]  Jeong Su Cho,et al.  Staple line coverage after bullectomy for primary spontaneous pneumothorax: a randomized trial. , 2014, The Annals of thoracic surgery.

[15]  S. O'Dea,et al.  Anatomy and bronchoscopy of the porcine lung. A model for translational respiratory medicine. , 2014, American journal of respiratory cell and molecular biology.

[16]  S. Oka,et al.  Triple-layer sealing with absorptive mesh and fibrin glue is effective in preventing air leakage after segmentectomy: results from experiments and clinical study. , 2014, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[17]  M. Stommel,et al.  Benefits and harms of adhesion barriers for abdominal surgery: a systematic review and meta-analysis , 2014, The Lancet.

[18]  L. Lin,et al.  Comparison of regenerated and non-regenerated oxidized cellulose hemostatic agents , 2013, European Surgery.

[19]  Yadong Wu,et al.  Oxidized regenerated cellulose-based hemostat with microscopically gradient structure , 2012 .

[20]  H. Kawai,et al.  Prevention of Alveolar Air Leakage after Video-Assisted Thoracic Surgery: Comparison of the Efficacy of Methods Involving the Use of Fibrin Glue , 2011, Thoracic and Cardiovascular Surgeon.

[21]  S. Force,et al.  Video-assisted thoracoscopic surgery segmentectomy: a safe and effective procedure. , 2010, The Annals of thoracic surgery.

[22]  Toru Nakamura,et al.  An evaluation of the surgical morbidity of polyglycolic acid felt in pulmonary resections , 2010, Surgery Today.

[23]  V. Rousson,et al.  Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study. , 2008, The Journal of thoracic and cardiovascular surgery.

[24]  S. Cho,et al.  Staple line covering procedure after thoracoscopic bullectomy for the management of primary spontaneous pneumothorax. , 2008, The Thoracic and cardiovascular surgeon.

[25]  H. Itano The optimal technique for combined application of fibrin sealant and bioabsorbable felt against alveolar air leakage. , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[26]  Tao-Sheng Li,et al.  Sutureless pneumostasis using polyglycolic acid mesh as artificial pleura during video-assisted major pulmonary resection. , 2007, The Annals of thoracic surgery.

[27]  T. Nagayasu,et al.  Development of new biodegradable hydrogel glue for preventing alveolar air leakage. , 2007, The Journal of thoracic and cardiovascular surgery.

[28]  Y. Izumi,et al.  The short-term efficacy of fibrin glue combined with absorptive sheet material in visceral pleural defect repair. , 2006, Interactive cardiovascular and thoracic surgery.

[29]  C. Vacanti,et al.  Polyglycolic acid-induced inflammation: role of hydrolysis and resulting complement activation. , 2006, Tissue engineering.

[30]  Yung‐Chie Lee,et al.  Using Surgicel to buttress the staple line in lung volume reduction surgery for chronic obstructive pulmonary disease. , 2006, The Journal of thoracic and cardiovascular surgery.

[31]  Masayuki Yamato,et al.  Cell sheet engineering: recreating tissues without biodegradable scaffolds. , 2005, Biomaterials.

[32]  R. W. Gracy,et al.  In vivo degradation of oxidized, regenerated cellulose. , 1990, Carbohydrate research.