Dorsal Plate Fixation for Dorsally Displaced Distal Radius Fractures

Received: February 4, 2014 Revised: March 10, 2014 Accepted: March 11, 2014 Correspondence to: Seok-Whan Song Department of Orthopedic Surgery, Yeouido St. Mary’s Hospital, The Catholic University of Korea College of Medicine, 10 63(yuksam)ro, Yeongdeungpo-gu, Seoul 150-713, Korea TEL: +82-2-3779-1192 FAX: +82-2-783-0252 E-mail: sw.song@catholic.ac.kr Purpose: The object of this study is to evaluate the clinical and radiographic outcomes of two different kinds of dorsal plating for dorsally displaced distal radius fractures. Methods: Forty-three patients with dorsal plate fixation for distal radius fracture were retrospectively reviewed. Twenty-four patients were treated with nonlocking dorsal plate (group I) and nineteen patients with locking dorsal plate (group II). Range of motion and Green and O’Brien score were evaluated as clinical results, and radial inclination, radial length, volar tilt at postoperative and last follow up were evaluated as radiographic results. Results: According to AO classification system, there were 18 type A fractures, 4 type B fractures, 21 type C fractures. In group I, the mean flexion and extension were 65.0° and 65.3°, respectively; ulnar and radial deviation were 25.5° and 20.8°; pronation and supination were 80.0° and 80.4°. In group II, the mean flexion and extension were 64.5° and 67.3°, respectively; ulnar and radial deviation were 30.6° and 20.6°; pronation and supination were 81.4° and 78.6°. The mean Green and O’Brien score was 94.4 in group I and 92.2 in group II, and 41 patients had satisfactory result. There was no statistical significant difference in clinical results between the groups. Results of postoperative and last follow-up radiographic analyses for mean radial inclination were 23.9° and 24.1° in group I, respectively, and 24.2° and 24.9° in group II; radial length were 9.9 mm and 9.7 mm in group I, and 10.1 mm and 9.2 mm in group II; mean volar tilt were 12.2° and 13.1° in group I, and 14.8° and 13.7° in group II . There were no statistical significant changes within radiographic parameters. No extensor tendon rupture was reported. Conclusion: Dorsal plate fixation for dorsally displaced distal radius fracture showed satisfactory clinical and radiographic outcomes with low complication rate, regardless of the type of plate.

[1]  S. K. Lee,et al.  Use of the radial groove view intra-operatively to prevent damage to the extensor pollicis longus tendon by protruding screws during volar plating of a distal radial fracture. , 2013, The bone & joint journal.

[2]  R. Attal,et al.  A new radiological method to detect dorsally penetrating screws when using volar locking plates in distal radial fractures. The dorsal horizon view. , 2013, The bone & joint journal.

[3]  C. Goldfarb,et al.  Dorsal locked plate fixation of distal radius fractures. , 2013, The Journal of hand surgery.

[4]  S. Tabrizi,et al.  Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study. , 2010, The Journal of hand surgery.

[5]  R. Buntic Low-Profile Dorsal Plating for Dorsally Angulated Distal Radius Fractures: An Outcomes Study , 2008 .

[6]  M. Moneim,et al.  Two Potential Causes of EPL Rupture after Distal Radius Volar Plate Fixation , 2006, Clinical orthopaedics and related research.

[7]  M. Gardner,et al.  Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment. , 2006, The Journal of hand surgery.

[8]  R. Idler,et al.  Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates. , 2005, The Journal of hand surgery.

[9]  D. Osada,et al.  Dorsal plating for comminuted intra-articular fractures of the distal end of the radius. , 2004, Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand.

[10]  S. Roach,et al.  Failure of a retinacular flap to prevent dorsal wrist pain after titanium Pi plate fixation of distal radius fractures. , 2002, The Journal of hand surgery.

[11]  J. Orbay,et al.  Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. , 2002, The Journal of hand surgery.

[12]  J. Jupiter,et al.  Complications following distal radial fractures. , 2001, Instructional course lectures.

[13]  D. Campbell Open Reduction and Internal Fixation of Intra Articular and Unstable Fractures of the Distal Radius Using the AO Distal Radius Plate , 2000, Journal of hand surgery.

[14]  J. Jupiter Plate fixation of fractures of the distal aspect of the radius: relative indications. , 1999, Journal of orthopaedic trauma.

[15]  T S Axelrod,et al.  Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: a brief report. , 1998, The Journal of hand surgery.

[16]  G. Laseter,et al.  Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: a multicenter study of 73 fractures. , 1998, The Journal of hand surgery.

[17]  D. Ring,et al.  Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. , 1997, The Journal of hand surgery.

[18]  J. Jupiter,et al.  Fracture of the distal radius: classification of treatment and indications for external fixation. , 1994, Injury.

[19]  R Y McMurtry,et al.  Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radius. , 1990, The Journal of hand surgery.