Complications Related to Cantilever Lengths in Implant-Supported Single Crowns

Prosthesis using implant has become a popular modality to treat edentulous patients for the last 35 years. The progress in surface treatment reduces the failure rate and provides better functional and esthetic restorations in dentistry. The earliest form of implant prosthesis was the splinted-fixed type. After full arch and partial edentulous prosthesis began to demon-strate s stable clinical successes rate, single crowns started to be restored with implants.When the implant supported single crown is located most distally in the arch, special biomechanical factors should be considered. Especially when the implant is placed in a more distal position, there will be exposure to tremendous lateral forces resulting in possible complications. The purpose of this study is to analyze the relationship between complications and distance from adjacent teeth to the implant, and to identify the types and frequency of complications. A total of 115 patients charts were investigated randomly from the implant clinic at Ewha WomansUniversity Hospital and Yonsei University Dental Hospital. The patients received an implant supported single crown from 1996 to 2007 and annual afterwards. Patients were grouped according to the pres-ence or lack of complications and the relationship of tooth to implant distance and complications was investigated. Age, sex, and abutment connection type were also analyzed for relationship with complications. The measured data from the two groups were analyzed statistically with SAS version 9.1 (SAS Inc., USA). There were significant statistical differences using logistic analysis (p<0.05) between the tooth to implant distance and complications. The odds ratio was 2.1 and cut off value from maximum value of specificity and sensitivity was 3.39 mm.

[1]  Bjarni E Pjetursson,et al.  A systematic review of the survival and complication rates of resin-bonded bridges after an observation period of at least 5 years , 2008, BDJ.

[2]  R. Haas,et al.  Peri-implant bone loss as a function of tooth-implant distance. , 2005, The International journal of prosthodontics.

[3]  Ameen Khraisat,et al.  Fatigue resistance of two implant/abutment joint designs. , 2002, The Journal of prosthetic dentistry.

[4]  U. Belser,et al.  Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. , 2000, The International journal of oral & maxillofacial implants.

[5]  H Salama,et al.  The interproximal height of bone: a guidepost to predictable aesthetic strategies and soft tissue contours in anterior tooth replacement. , 1998, Practical periodontics and aesthetic dentistry : PPAD.

[6]  P Lockowandt,et al.  Comparison of strength and failure mode of seven implant systems: an in vitro test. , 1997, The Journal of prosthetic dentistry.

[7]  M. Norton,et al.  An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. , 1997, Clinical oral implants research.

[8]  C. Malevez,et al.  Marginal bone levels at Brånemark system implants used for single tooth restoration. The influence of implant design and anatomical region. , 1996, Clinical oral implants research.

[9]  B Rangert,et al.  Bending overload and implant fracture: a retrospective clinical analysis. , 1995, The International journal of oral & maxillofacial implants.

[10]  G Watzek,et al.  Brånemark single tooth implants: a preliminary report of 76 implants. , 1995, The Journal of prosthetic dentistry.

[11]  S. Aquilino,et al.  Cantilever and implant biomechanics: a review of the literature, Part 2. , 1994, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[12]  S. Aquilino,et al.  Cantilever and implant biomechanics: a review of the literature. Part 1. , 1994, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[13]  G E Carlsson,et al.  Clinical evaluation of single-tooth restorations supported by osseointegrated implants: a retrospective study. , 1994, The International journal of oral & maxillofacial implants.

[14]  D. Sullivan Wide implants for wide teeth. , 1994, Dental economics - oral hygiene.

[15]  P J Becker,et al.  Survival of fixed implant-supported prostheses related to cantilever lengths. , 1994, The Journal of prosthetic dentistry.

[16]  A Schmitt,et al.  The longitudinal clinical effectiveness of osseointegrated dental implants for single-tooth replacement. , 1993, The International journal of prosthodontics.

[17]  D van Steenberghe,et al.  Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system. , 1992, Clinical oral implants research.

[18]  T Jemt,et al.  Failures and complications in 127 consecutively placed fixed partial prostheses supported by Brånemark implants: from prosthetic treatment to first annual checkup. , 1992, The International journal of oral & maxillofacial implants.

[19]  M. Quirynen,et al.  A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism. , 1992, The Journal of prosthetic dentistry.

[20]  I Herrmann,et al.  Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study. , 1991, The International journal of oral & maxillofacial implants.

[21]  B Rangert,et al.  Forces and moments on Branemark implants. , 1989, The International journal of oral & maxillofacial implants.

[22]  F. M. Gardner,et al.  A survey of crown and fixed partial denture failures: length of service and reasons for replacement. , 1986, The Journal of prosthetic dentistry.

[23]  P. Branemark,et al.  Marginal tissue reactions at osseointegrated titanium fixtures (I). A 3-year longitudinal prospective study. , 1986, International journal of oral and maxillofacial surgery.

[24]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[25]  J. L. Stewart,et al.  Unserviceable crowns and fixed partial dentures: life-span and causes for loss of serviceability. , 1970, Journal of the American Dental Association.

[26]  Ralph W. Phillips,et al.  Modern practice in crown and bridge prosthodontics , 1965 .