New spatial localizer based on fiber optics with applications in 3D ultrasound imaging

Spatial localizers provide a reference coordinate system and make the tracking of various objects in 3D space feasible. A number of different spatial localizers are currently available. Several factors that determine the suitability of a position sensor for a specific clinical application are accuracy, ease of use, and robustness of performance when used in a clinical environment. In this paper, we present a new and low-cost sensor with performance unaffected by a the materials present in the operating environment. This new spatial localizer consists of a flexible tape with a number of fiber optic sensor along its length. The main idea is that we can obtain the position and orientation of the end of the tape with respect to its base. The end and base of the tape are locations along its length determined by the physical location of the fiber optic sensors. Using this tape, we tracked an ultrasound probe and formed 3D US data sets. In order to validate the geometric accuracy of those 3D data sets, we measured known volumes of water-filled balloons. Our results indicate that we can measure volumes with accuracy between 2-16 percent. Given the fact that the sensor is under further development and refinement, we expect that this sensor could be an accurate, cost-effective and robust alternative in many medical applications, e.g., image-guided surgery and 3D ultrasound imaging.

[1]  Dudley H. Davis,et al.  Textbook of Stereotactic and Functional Neurosurgery , 1998 .

[2]  T. Nelson,et al.  Distance and volume measurement using three‐dimensional ultrasonography. , 1995, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[3]  E. Rinast,et al.  Follow-up study of renal transplants by duplex Doppler and gray-scale ultrasound. , 1992, European journal of radiology.

[4]  W D Richard,et al.  Three-dimensional imaging with stereotactic ultrasonography. , 1994, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[5]  F. Candiani,et al.  The latest in ultrasound: three-dimensional imaging. Part 1. , 1998, European journal of radiology.

[6]  H. Oosting,et al.  Second-trimester placental volume measurement by ultrasound: prediction of fetal outcome. , 1989, American journal of obstetrics and gynecology.

[7]  A. Pantuck,et al.  Prostate specific antigen density: a means of distinguishing benign prostatic hypertrophy and prostate cancer. , 1992, The Journal of urology.

[8]  F. Chang,et al.  Three-dimensional ultrasound assessment of fetal liver volume in normal pregnancy: a comparison of reproducibility with two-dimensional ultrasound and a search for a volume constant. , 1997, Ultrasound in medicine & biology.

[9]  A. Fenster,et al.  3-D ultrasound imaging: a review , 1996 .