Results of speech perception and speech production training for three prelingually deaf patients using a multiple-electrode cochlear implant.

Five studies were conducted to measure changes in the perception and production of selected speech targets, with training, in three prelingually deaf patients. The two adults and one adolescent were implanted with the Cochlear (Nucleus) multiple-electrode prosthesis. The studies were perception and production of nasal consonants; perception of syllable-final consonants; perception and production of alveolar consonants; auditory-visual perception of alveolar consonants; and perception and production of vowels. Perceptual data were collected in the audition (implant)-alone condition, except for the auditory-visual perception of alveolar consonants where the audition-alone, vision-alone, and auditory-visual conditions were used. Speech perception data in the audition-alone condition were also collected from four postlingually deaf adult implant patients, without training, to indicate differences between the two classes of patients. The three prelingually deaf patients generally showed some improvements in speech production. In perception, improvements were recorded only for individual patients in some studies. The performance of the adolescent was better than that of the two adults in all cases. The perceptual performance of the postlingually deaf patients was superior to that of the prelingually deaf patients in all cases.

[1]  L. Eisenberg,et al.  Audiological Results in Children with a Cochlear Implant , 1985, Ear and hearing.

[2]  D. Oller,et al.  Developmental Aspects Influencing Implantation and Rehabilitation of Children , 1986 .

[3]  T. Waters Speech therapy with cochlear implant wearers. , 1986, British journal of audiology.

[4]  A. Markides The speech of deaf and partially-hearing children with special reference to factors affecting intelligibility. , 1970, The British journal of disorders of communication.

[5]  J B Spitzer,et al.  Reacquisition of contrastive stress in an adventitiously deaf speaker using a single-channel cochlear implant. , 1986, The Journal of the Acoustical Society of America.

[6]  A. Thornton,et al.  Speech-discrimination scores modeled as a binomial variable. , 1978, Journal of speech and hearing research.

[7]  C. Smith,et al.  Residual hearing and speech production in deaf children. , 1975, Journal of speech and hearing research.

[8]  G M Clark,et al.  Results of a Preliminary Clinical Trial on a Multiple Channel Cochlear Prosthesis , 1985, The Annals of otology, rhinology, and laryngology.

[9]  G M Clark,et al.  Perceptual studies on cochlear implant patients with early onset of profound hearing impairment prior to normal development of auditory, speech, and language skills. , 1988, The Journal of the Acoustical Society of America.

[10]  J M Pickett,et al.  Auditory implants and tactile aids for the profoundly deaf. , 1985, Journal of speech and hearing research.

[11]  P M Seligman,et al.  A signal processor for a multiple-electrode hearing prosthesis. , 1984, Acta oto-laryngologica. Supplementum.

[12]  Karen ller Kirk,et al.  Speech and Language Results in Children with a Cochlear Implant , 1985, Ear and hearing.

[13]  A E Geers,et al.  Predicting long-term benefits from single-channel cochlear implants in profoundly hearing-impaired children. , 1988, The American journal of otology.

[14]  M. J. Osberger Training effects on vowel production by two profoundly hearing-impaired speakers. , 1987, Journal of speech and hearing research.

[15]  G. Clark,et al.  Acoustic parameters measured by a formant-estimating speech processor for a multiple-channel cochlear implant. , 1987, The Journal of the Acoustical Society of America.

[16]  Bruce J. Gantz,et al.  Evaluation of four Cochlear Implant Designs , 1987 .

[17]  J B Millar,et al.  Speech processing for cochlear implant prostheses. , 1984, Journal of speech and hearing research.

[18]  Graeme M. Clark,et al.  Surgery for an Improved Multiple-Channel Cochlear Implant , 1984, The Annals of otology, rhinology, and laryngology.

[19]  K I Kirk,et al.  The effects of cochlear implant use on voice parameters. , 1983, Otolaryngologic clinics of North America.

[20]  P. Blamey,et al.  Results for two children using a multiple-electrode intracochlear implant. , 1989, The Journal of the Acoustical Society of America.