System for routine surface anthropometry using reprojection registration

Range data measurement can be usefully applied to non-invasive monitoring of anthropometric changes due to disease, healing or during normal physiological processes. We have developed a computer vision system that allows routine capture of biological surface shapes and accurate measurement of anthropometric changes, using a structured light stripe triangulation system. In many applications involving relocation of soft tissue for image-guided surgery or anthropometry it is neither accurate nor practical to apply fiducial markers directly to the body. This system features a novel method of achieving subject re-registration that involves application of fiducials by a standard data projector. Calibration of this reprojector is achieved using a variation of structured lighting techniques. The method allows accurate and comparable repositioning of elastic surfaces. Tests of repositioning using the reprojector found a significant improvement in subject registration compared to an earlier method which used video overlay comparison only. It has a current application to the measurement of breast volume changes in lactating mothers, but may be extended to any application where repeatable positioning and measurement is required.

[1]  Brian F. Alexander,et al.  3-D Shape Measurement By Active Triangulation Using An Array Of Coded Light Stripes , 1988, Other Conferences.

[2]  Margaret C. Neville,et al.  E – The Physical Properties of Human and Bovine Milks , 1995 .

[3]  Philippe Cinquin,et al.  Using a 3D Position Sensor for Registration of SPECT and US Images of the Kidney , 1995, CVRMed.

[4]  Y. Ge,et al.  Noncontact 3D biological shape measurement from multiple views , 1994 .

[5]  W. Eric L. Grimson,et al.  An automatic registration method for frameless stereotaxy, image guided surgery, and enhanced reality visualization , 1994, 1994 Proceedings of IEEE Conference on Computer Vision and Pattern Recognition.

[6]  Max A. Viergever,et al.  A survey of medical image registration , 1998, Medical Image Anal..

[7]  L. Verhey,et al.  Computer-assisted positioning of radiotherapy patients using implanted radiopaque fiducials. , 1993, Medical physics.

[8]  Richard Szeliski,et al.  Anatomy-Based Registration for Computer-Integrated Surgery , 1995, CVRMed.

[9]  C. Pelizzari,et al.  Frameless stereotaxy with real-time tracking of patient head movement and retrospective patient-image registration. , 1996, Journal of neurosurgery.

[10]  J.T. Lewis,et al.  An ultrasonic approach to localization of fiducial markers for interactive, image-guided neurosurgery. I. Principles , 1998, IEEE Transactions on Biomedical Engineering.

[11]  Robert J. Maciunas,et al.  Registration of head volume images using implantable fiducial markers , 1997, IEEE Transactions on Medical Imaging.

[12]  William E. Lorensen,et al.  Image guidance techniques for neurosurgery , 1994, Other Conferences.

[13]  Richard J. Evans,et al.  Development and preliminary evaluation of VISLAN, a surgical planning and guidance system using intra-operative video imaging , 1996, Medical Image Anal..

[14]  Tomas Lozano-Perez,et al.  An automatic registration method for frameless stereotaxy, image guided surgery, and enhanced reality visualization , 1996 .

[15]  D L McShan,et al.  Automated determination of patient setup errors in radiation therapy using spherical radio-opaque markers. , 1993, Medical physics.

[16]  O. Faugeras Three-dimensional computer vision: a geometric viewpoint , 1993 .