Estimating Respiratory Rate in Post-Anesthesia Care Unit Patients Using Infrared Thermography: An Observational Study

The post-anesthesia care unit (PACU) is the central hub for recovery after surgery, especially when the surgery is performed under general anesthesia. Aside from clinical aspects, respiratory impairment is one of the major causes of morbidity and affected recovery in the PACU and should therefore be monitored. In previous studies, infrared thermography was applied to assess the breathing rate (BR) of healthy volunteers. Here, the transferability of published methods for postoperative patients in the PACU was examined. Video recordings of 28 patients were acquired using a long-wave infrared camera, and analyzed offline. For validation purposes, BRs derived from body surface electrocardiography were measured simultaneously. In general, a close agreement between the two techniques (r = 0.607, p = 0.002 upon arrival, and r = 0.849, p < 0.001 upon discharge from the PACU) was obtained. In conclusion, the algorithm was demonstrated to be feasible and reliable under these challenging conditions.

[1]  Mahesh Motwani,et al.  Image segmentation for the extraction of face using haar like feature , 2016, Int. Arab J. Inf. Technol..

[2]  P. Papadakos,et al.  Respiratory complications in the postanesthesia care unit: A review of pathophysiological mechanisms , 2013, Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR.

[3]  R. Anderson,et al.  Skin Surface Temperatures Measured by Thermal Imaging Aid in the Diagnosis of Cellulitis. , 2017, The Journal of investigative dermatology.

[4]  Jarrod E Dalton,et al.  Postoperative Hypoxemia Is Common and Persistent: A Prospective Blinded Observational Study , 2015, Anesthesia and analgesia.

[5]  Erik Olofsen,et al.  Frequent respiratory events in postoperative patients aged 60 years and above , 2017, Therapeutics and clinical risk management.

[6]  Robert Koprowski,et al.  Some selected quantitative methods of thermal image analysis in Matlab , 2016, Journal of biophotonics.

[7]  João Carlos Bouzas Marins,et al.  Classification of factors influencing the use of infrared thermography in humans: A review , 2015 .

[8]  Steffen Leonhardt,et al.  Contact-free monitoring of circulation and perfusion dynamics based on the analysis of thermal imagery. , 2014, Biomedical optics express.

[9]  Reza Saatchi,et al.  Thermal image processing for real-time non-contact respiration rate monitoring , 2017, IET Circuits Devices Syst..

[10]  S. Lalani,et al.  Prolonged-stay patients in the PACU: a review of the literature. , 2013, Journal of perianesthesia nursing : official journal of the American Society of PeriAnesthesia Nurses.

[11]  R. Saatchi,et al.  Respiration rate monitoring methods: A review , 2011, Pediatric pulmonology.

[12]  Bob D Guenther,et al.  Thermoregulation and Thermography in Neonatal Physiology and Disease , 2011, Biological research for nursing.

[13]  Y. Martin,et al.  Low minute ventilation episodes during anesthesia recovery following intraperitoneal surgery as detected by a non-invasive respiratory volume monitor , 2018, Journal of clinical monitoring and computing.

[14]  O. Boric-Lubecke,et al.  Non-contact respiratory rate measurement validation for hospitalized patients , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[15]  Ioannis T. Pavlidis,et al.  Thermistor at a Distance: Unobtrusive Measurement of Breathing , 2010, IEEE Transactions on Biomedical Engineering.

[16]  Robert Koprowski,et al.  Automatic analysis of the trunk thermal images from healthy subjects and patients with faulty posture , 2015, Comput. Biol. Medicine.

[17]  O. Airaksinen,et al.  Reproducibility of infrared thermography measurements in healthy individuals , 2008, Physiological measurement.

[18]  Haibin Ling,et al.  Robust Visual Tracking and Vehicle Classification via Sparse Representation , 2011, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[19]  S Leonhardt,et al.  Robust inter-beat interval estimation in cardiac vibration signals , 2013, Physiological measurement.

[20]  Steffen Leonhardt,et al.  Robust remote monitoring of breathing function by using infrared thermography , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[21]  Steffen Leonhardt,et al.  Remote monitoring of breathing dynamics using infrared thermography. , 2015, Biomedical optics express.

[22]  U. Koehler,et al.  [Respiratory Rate - a Neglected Vital Sign]. , 2017, Deutsche medizinische Wochenschrift.

[23]  A. Drucker,et al.  Hot Stuff: Thermal Imaging Aids in Cellulitis Diagnosis. , 2018, The Journal of investigative dermatology.

[24]  François Michaud,et al.  Contact-Free Respiration Rate Monitoring Using a Pan–Tilt Thermal Camera for Stationary Bike Telerehabilitation Sessions , 2016, IEEE Systems Journal.

[25]  Mariusz Marzec,et al.  Methods of face localization in thermograms , 2015 .

[26]  Nicolai Marquardt,et al.  Robust tracking of respiratory rate in high-dynamic range scenes using mobile thermal imaging. , 2017, Biomedical optics express.

[27]  Wenhan Zhu,et al.  Combination of near-infrared and thermal imaging techniques for the remote and simultaneous measurements of breathing and heart rates under sleep situation , 2018, PloS one.

[28]  L. Feldman,et al.  What outcomes are important in the assessment of Enhanced Recovery After Surgery (ERAS) pathways? , 2015, Canadian Journal of Anesthesia/Journal canadien d'anesthésie.

[29]  Marc Garbey,et al.  Contact-Free Measurement of Cardiac Pulse Based on the Analysis of Thermal Imagery , 2007, IEEE Transactions on Biomedical Engineering.

[30]  Glenn J Tattersall,et al.  Infrared thermography: A non-invasive window into thermal physiology. , 2016, Comparative biochemistry and physiology. Part A, Molecular & integrative physiology.

[31]  Nilkantha Gupta,et al.  Computer-based automated analysis of X-ray and thermal imaging of knee region in evaluation of rheumatoid arthritis , 2017, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[32]  Reza Saatchi,et al.  Tracking human face features in thermal images for respiration monitoring , 2010, ACS/IEEE International Conference on Computer Systems and Applications - AICCSA 2010.

[33]  B. Debaene,et al.  Accuracy of respiratory rate monitoring by capnometry using the Capnomask(R) in extubated patients receiving supplemental oxygen after surgery. , 2012, British journal of anaesthesia.

[34]  Gregory F. Lewis,et al.  A novel method for extracting respiration rate and relative tidal volume from infrared thermography. , 2011, Psychophysiology.

[35]  E. Ring,et al.  The technique of infrared imaging in medicine , 2015 .

[36]  M. Cohen,et al.  Critical Respiratory Events in the Postanesthesia Care Unit: Patient, Surgical, and Anesthetic Factors , 1994, Anesthesiology.