A Study on Increasing Sensitivity of Rectangular Microcantilevers Used in Biosensors

This study proposes a new microcantilever design with a rectangular hole at the fixed end of the cantilever that is more sensitive than conventional ones. A commercial finite element analysis software ANSYS is used to analyze it. The Stoney equation is first used to calculate the surface stress induced moment, and then applied to the microcantilever free end to produce deflection. The stress analysis of the proposed and conventional designs is performed, followed by dynamic analysis of the proposed design. We found that the Sader equation is more accurate than Stoney in predicting cantilever deflections, and that for increasing the sensitivity of a microcantilever biosensor increasing the cantilever thickness is more practical.

[1]  G. Stoney The Tension of Metallic Films Deposited by Electrolysis , 1909 .

[2]  Javier Tamayo,et al.  Label-free detection of DNA hybridization based on hydration-induced tension in nucleic acid films. , 2008, Nature nanotechnology.

[3]  H. Rothuizen,et al.  Translating biomolecular recognition into nanomechanics. , 2000, Science.

[4]  J. Therasse,et al.  Validation of antibody-based recognition by piezoelectric transducers through electroacoustic admittance analysis. , 1998, Biosensors & bioelectronics.

[5]  A K Chakraborty,et al.  Origin of nanomechanical cantilever motion generated from biomolecular interactions. , 2001, Proceedings of the National Academy of Sciences of the United States of America.

[6]  Anja Boisen,et al.  SU-8 Cantilevers for Bio/chemical Sensing; Fabrication, Characterisation and Development of Novel Read-out Methods , 2008, Sensors.

[7]  R. Corn,et al.  Surface plasmon resonance imaging measurements of DNA and RNA hybridization adsorption onto DNA microarrays. , 2001, Analytical chemistry.

[8]  W. Grange,et al.  Rapid and label-free nanomechanical detection of biomarker transcripts in human RNA , 2006, Nature nanotechnology.

[9]  Anja Boisen,et al.  Polymeric cantilever-based biosensors with integrated readout , 2006 .

[10]  H. Lang,et al.  Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever array , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[11]  Dirk Sander,et al.  Cantilever measurements of surface stress, surface reconstruction, film stress and magnetoelastic stress of monolayers , 2008, Sensors.

[12]  Gajendra S Shekhawat,et al.  Label-free ultra-sensitive detection of atrazine based on nanomechanics , 2008, Nanotechnology.

[13]  R. McKendry,et al.  SU8 bio-chemical sensor microarrays , 2006 .

[14]  X. Richard Zhang,et al.  Development of a biosensor based on laser-fabricatedpolymer microcantilevers , 2004 .

[15]  Javier Tamayo,et al.  Study of the Origin of Bending Induced by Bimetallic Effect on Microcantilever , 2007, Sensors.

[16]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[17]  Wenmiao Shu,et al.  Label-free detection of amyloid growth with microcantilever sensors. , 2008, Nanotechnology.

[18]  John E. Sader,et al.  Surface stress induced deflections of cantilever plates with applications to the atomic force microscope: Rectangular plates , 2001 .

[19]  K.E. Petersen,et al.  Silicon as a mechanical material , 1982, Proceedings of the IEEE.

[20]  Johannes D. Seelig,et al.  Label-free protein assay based on a nanomechanical cantilever array , 2002 .

[21]  L M Lechuga,et al.  Highly sensitive polymer-based cantilever-sensors for DNA detection. , 2005, Ultramicroscopy.