Development and evaluation of a dual-head PET system for high-throughput small-animal imaging

We investigate the development of high-throughput small-animal PET systems that are suitable for use in screening applications. To the best of our knowledge, imaging throughput has never been explicitly considered as a target performance parameter in PET design. Therefore, it remains unclear how to achieve the desired system performance characteristics and what design issues need to be addressed. This paper presents the first of a series of study that we will conduct to systematically examine and understand the complicated tradeoffs among various design parameters that are involved, in order to produce design guidelines for realizing the proposed high-throughput small-animal PET systems. In particular, we will consider a compact, stationary system that employ two parallel large-area planar detectors with a small spacing between them. We will present considerations that favor this scanner configuration and conduct computer simulations to evaluate its detection performance. The results of our studies indicate that the proposed system configuration is rather favorable.

[1]  A. Jeavons,et al.  A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[2]  Alan J. Fischman,et al.  Development of a small animal PET imaging device with resolution approaching 1 mm , 1999 .

[3]  William W. Moses,et al.  Conceptual design of a high-sensitivity small animal PET camera with 4/spl pi/ coverage , 1999 .

[4]  A. Del Guerra,et al.  YAP-PET: first results of a small animal positron emission tomograph based on YAP:Ce finger crystals , 1998 .

[5]  M. Phelps,et al.  PET: the merging of biology and imaging into molecular imaging. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  S. Cherry,et al.  Performance evaluation of microPET: a high-resolution lutetium oxyorthosilicate PET scanner for animal imaging. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  Wai-Hoi Wong,et al.  A positron camera detector design with cross-coupled scintillators and quadrant sharing photomultipliers , 1992 .

[8]  Xiaochuan Pan,et al.  An exact Fourier rebinning algorithm for 3D PET imaging using panel detectors. , 2004, Physics in medicine and biology.

[9]  Magdalena Rafecas,et al.  A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals , 2001, European Journal of Nuclear Medicine.

[10]  Thomas K. Lewellen,et al.  Performance characteristics of micro crystal element (MiCE) detectors , 2000 .

[11]  Jurgen Seidel,et al.  Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: comparison to simulated LSO scanners without depth-of-interaction capability , 2001 .

[12]  Nan Zhang,et al.  Basic imaging performance characteristics of a variable field of view PET camera using quadrant sharing detector design , 1998 .

[13]  Klaus Wienhard,et al.  The ECAT HRRT: performance and first clinical application of the new high resolution research tomograph , 2000 .

[14]  S. Cherry,et al.  MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging. , 2003, Physics in medicine and biology.