Novel transmit protection scheme for ultrasound systems

The problem of protecting or isolating extremely sensitive receive circuitry from high-voltage transmit circuitry is commonly addressed through the use of diode bridges, transformers, or high-voltage switches, which prove to be prohibitively expensive, bulky, and power consuming for use in portable, low-cost, battery-powered systems. These approaches also compound the interconnect difficulties associated with two-dimensional (2-D) transducer arrays. In this paper we present a novel transmit protection scheme that allows compact MOSFET shunting devices to be brought on-chip within each receive channel implemented in a standard CMOS integrated circuit process. During transmit, the high voltage transmit pulse is driven onto the common connection of the transducer array and the on-chip MOSFET devices shunt the current to ground. During receive, these devices are turned off, the common connection of the transducer array is shunted to ground, and the received echo can be detected as usual. The transmit protection scheme was experimentally shown to shunt a 16 mA peak current resulting from the equivalent of a 100-V, 25-ns-risetime transmit pulse through a 4 pF transducer element. The scheme was also incorporated into a prototype 1024-channel, low-cost, ultrasound system successfully used to form pulse echo images.

[1]  Anthony N. Sinclair,et al.  Protection circuitry and time resolution in high frequency ultrasonic NDE , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).

[2]  David A. Johns,et al.  Analog Integrated Circuit Design , 1996 .

[3]  T. Rhyne Characterizing ultrasonic transducers using radiation efficiency and reception noise figure , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  S.W. Smith,et al.  Multi-layered PZT/polymer composites to increase signal-to-noise ratio and resolution for medical ultrasound transducers , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  J.W. Hunt,et al.  The design of protection circuitry for high-frequency ultrasound imaging systems , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Anthony M. Nicoli,et al.  A 128/spl times/128 ultrasonic transducer hybrid array , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[7]  K. Ranganathan,et al.  Portable, low-cost medical ultrasound device prototype , 2004, IEEE Ultrasonics Symposium, 2004.

[8]  T. Letavic,et al.  Digitally controlled high-voltage analog switch array for medical ultrasound applications in thin-layer silicon-on-insulator process , 2002, 2002 IEEE International SOI Conference.

[9]  Gordon Hayward,et al.  A model for low noise design of ultrasonic transducers , 1995, 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium.

[10]  J. K. Poulsen Low loss wideband protection circuit for high frequency ultrasound , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).

[11]  O. Oralkan,et al.  Integrated ultrasonic imaging systems based on CMUT arrays: recent progress , 2004, IEEE Ultrasonics Symposium, 2004.

[12]  T. White,et al.  Three-dimensional ultrasonic imaging with a fully populated 128/spl times/128 array , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[13]  A. Bozkurt,et al.  Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  Travis N. Blalock,et al.  High element count two dimensional transducer array , 2003, IEEE Symposium on Ultrasonics, 2003.