System reconfiguration under open-switch faults in a doubly fed induction machine

The aim of this study is to present system reconfiguration for a doubly fed induction machine (DFIM) after an open-switch fault is detected in its back-to-back converters. The open-switch fault and its detection for the scheme are discussed first. System reconfiguration is applied to operate the DFIM after the fault is detected. A four-switch converter topology with dc-link midpoint connection is selected to reconfigure the system. An existing pulse-width modulation method is investigated and applied to reconfigure the system, but uncontrollable capacitor voltage drift occurs. This study proposes a technique to solve the drift problem and also improve the quality of the dc-link voltage. Its effectiveness is substantiated by both simulation and experiment.

[1]  Thomas A. Lipo,et al.  DC link voltage control of reduced switch VSI-PWM rectifier/inverter system , 1997, Proceedings of the IECON'97 23rd International Conference on Industrial Electronics, Control, and Instrumentation (Cat. No.97CH36066).

[2]  Bimal K. Bose,et al.  Investigation of fault modes of voltage-fed inverter system for induction motor drive , 1992, Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting.

[3]  P. Vas Vector control of AC machines , 1990 .

[4]  M.N. Uddin,et al.  Fuzzy-logic-controller-based cost-effective four-switch three-phase inverter-fed IPM synchronous motor drive system , 2006, IEEE Transactions on Industry Applications.

[5]  F.W. Fuchs,et al.  Performance of diagnosis methods for IGBT open circuit faults in voltage source active rectifiers , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[6]  A.M.N. Lima,et al.  Induction motor drive system for low power applications , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[7]  Ching-Tsai Pan,et al.  Modelling and design of a reversible three-phase switching mode rectifier , 1997 .

[8]  T. S. Radwan,et al.  Fuzzy logic controller based cost effective 4-switch, 3-phase inverter fed IPM synchronous motor drive system , 2004, Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting..

[9]  Bor-Ren Lin,et al.  Implementation of three-phase power factor correction circuit with less power switches and current sensors , 1998 .

[10]  R. Peuget,et al.  Two knowledge-based approaches to fault detection and isolation on a PWM inverter , 1997, Proceedings of the 1997 IEEE International Conference on Control Applications.

[11]  Grant A. Covic,et al.  DC link imbalance compensation in four-switch inverter AC motor drives , 1997 .

[12]  Grant A. Covic,et al.  Eliminating output distortion in four-switch inverters with three-phase loads , 1998 .

[13]  T.A. Lipo,et al.  Fault tolerant three-phase AC motor drive topologies: a comparison of features, cost, and limitations , 2003, IEEE Transactions on Power Electronics.

[14]  J. T. Boys,et al.  An improved single phase to three phase converter for low cost AC motor drives , 1995, Proceedings of 1995 International Conference on Power Electronics and Drive Systems. PEDS 95.

[15]  C.B. Jacobina,et al.  A General PWM Strategy for Four-Switch Three-Phase Inverters , 2006, IEEE Transactions on Power Electronics.

[16]  R. Peuget,et al.  Fault detection and isolation on a PWM inverter by knowledge-based model , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[17]  Warachart Sae-Kok Converter fault diagnosis and post-fault operation of a doubly-fed induction generator for a wind turbine , 2008 .

[18]  Jacobus Daniel van Wyk,et al.  A Comparative Investigation of a Three-Phase Induction Machine Drive with a Component Minimized Voltage-Fed Inverter under Different Control Options , 1984 .

[19]  Mehrdad Ehsani,et al.  On the feasibility of four-switch three-phase BLDC motor drives for low cost commercial applications: topology and control , 2003 .

[20]  Thomas A. Lipo,et al.  VSI-PWM rectifier/inverter system with a reduced switch count , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[21]  Huang-Jen Chiu,et al.  Three-phase active power filter for power quality compensation , 2003, The Fifth International Conference on Power Electronics and Drive Systems, 2003. PEDS 2003..

[22]  Henry Shu-Hung Chung,et al.  Circuit-level comparison of STATCOM technologies , 2003 .

[23]  Frede Blaabjerg,et al.  Adaptive SVM to compensate DC-link voltage ripple for four-switch three-phase voltage-source inverters , 1999 .

[24]  W. Sae-Kok,et al.  Open Switch Fault Diagnosis for a Doubly-Fed Induction Generator , 2007, 2007 7th International Conference on Power Electronics and Drive Systems.

[25]  Frede Blaabjerg,et al.  A new optimized space-vector modulation strategy for a component-minimized voltage source inverter , 1997 .