Automatic discrimination between safe and unsafe swallowing using a reputation-based classifier

BackgroundSwallowing accelerometry has been suggested as a potential non-invasive tool for bedside dysphagia screening. Various vibratory signal features and complementary measurement modalities have been put forth in the literature for the potential discrimination between safe and unsafe swallowing. To date, automatic classification of swallowing accelerometry has exclusively involved a single-axis of vibration although a second axis is known to contain additional information about the nature of the swallow. Furthermore, the only published attempt at automatic classification in adult patients has been based on a small sample of swallowing vibrations.MethodsIn this paper, a large corpus of dual-axis accelerometric signals were collected from 30 older adults (aged 65.47 ± 13.4 years, 15 male) referred to videofluoroscopic examination on the suspicion of dysphagia. We invoked a reputation-based classifier combination to automatically categorize the dual-axis accelerometric signals into safe and unsafe swallows, as labeled via videofluoroscopic review. From these participants, a total of 224 swallowing samples were obtained, 164 of which were labeled as unsafe swallows (swallows where the bolus entered the airway) and 60 as safe swallows. Three separate support vector machine (SVM) classifiers and eight different features were selected for classification.ResultsWith selected time, frequency and information theoretic features, the reputation-based algorithm distinguished between safe and unsafe swallowing with promising accuracy (80.48 ± 5.0%), high sensitivity (97.1 ± 2%) and modest specificity (64 ± 8.8%). Interpretation of the most discriminatory features revealed that in general, unsafe swallows had lower mean vibration amplitude and faster autocorrelation decay, suggestive of decreased hyoid excursion and compromised coordination, respectively. Further, owing to its performance-based weighting of component classifiers, the static reputation-based algorithm outperformed the democratic majority voting algorithm on this clinical data set.ConclusionGiven its computational efficiency and high sensitivity, reputation-based classification of dual-axis accelerometry ought to be considered in future developments of a point-of-care swallow assessment where clinical informatics are desired.

[1]  T Chau,et al.  Time and time–frequency characterization of dual-axis swallowing accelerometry signals , 2008, Physiological measurement.

[2]  Thy-Hou Lin,et al.  Implementing the Fisher's Discriminant Ratio in a k-Means Clustering Algorithm for Feature Selection and Data Set Trimming , 2004, Journal of Chemical Information and Modeling.

[3]  T. Chau,et al.  A procedure for denoising dual-axis swallowing accelerometry signals , 2010, Physiological measurement.

[4]  Adam Krzyżak,et al.  Methods of combining multiple classifiers and their applications to handwriting recognition , 1992, IEEE Trans. Syst. Man Cybern..

[5]  Bruce E. Murdoch,et al.  The Physiologic Cause of Swallowing Sounds: Answers from Heart Sounds and Vocal Tract Acoustics , 1998, Dysphagia.

[6]  Anil K. Jain,et al.  Statistical Pattern Recognition: A Review , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[7]  Arthur J. Miller,et al.  Book Reviews: The Neuroscientific Principles of Swallowing and Dysphagia , 1999 .

[8]  Tom Chau,et al.  Baseline Characteristics of Dual-Axis Cervical Accelerometry Signals , 2010, Annals of Biomedical Engineering.

[9]  Tom Chau,et al.  A radial basis classifier for the automatic detection of aspiration in children with dysphagia , 2006, Journal of NeuroEngineering and Rehabilitation.

[10]  Yuh-Min Tseng,et al.  A free-rider aware reputation system for peer-to-peer file-sharing networks , 2011, Expert Syst. Appl..

[11]  Tom Chau,et al.  Anthropometric and Demographic Correlates of Dual-Axis Swallowing Accelerometry Signal Characteristics: A Canonical Correlation Analysis , 2010, Dysphagia.

[12]  Ellen B. Roecker,et al.  A penetration-aspiration scale , 2004, Dysphagia.

[13]  Jo Shapiro,et al.  Evaluation and treatment of swallowing disorders , 1992, Comprehensive therapy.

[14]  S. T. Buckland,et al.  An Introduction to the Bootstrap. , 1994 .

[15]  N. P. Reddy,et al.  Measurements of acceleration during videofluorographic evaluation of dysphagic patients. , 2000, Medical engineering & physics.

[16]  Youngsun Kim,et al.  Maximum Hyoid Displacement in Normal Swallowing , 2008, Dysphagia.

[17]  Tom Chau,et al.  Classification of healthy and abnormal swallows based on accelerometry and nasal airflow signals , 2011, Artif. Intell. Medicine.

[18]  David G. Stork,et al.  Pattern Classification , 1973 .

[19]  Abraham Lempel,et al.  On the Complexity of Finite Sequences , 1976, IEEE Trans. Inf. Theory.

[20]  Irena Orovic,et al.  Time-Frequency Analysis and Hermite Projection Method Applied to Swallowing Accelerometry Signals , 2010, EURASIP J. Adv. Signal Process..

[21]  David G. Stork,et al.  Pattern classification, 2nd Edition , 2000 .

[22]  Amitava Das,et al.  Hybrid fuzzy logic committee neural networks for recognition of swallow acceleration signals , 2001, Comput. Methods Programs Biomed..

[23]  Zbigniew Kotulski,et al.  Reputation as optimality measure in Wireless Sensor Network-based monitoring systems , 2011 .

[24]  Abtin Tabaee,et al.  Patient‐Controlled Comparison of Flexible Endoscopic Evaluation of Swallowing With Sensory Testing (FEESST) and Videofluoroscopy , 2006, The Laryngoscope.

[25]  T Chau,et al.  Hyolaryngeal excursion as the physiological source of swallowing accelerometry signals , 2010, Physiological measurement.

[26]  Robert Tibshirani,et al.  An Introduction to the Bootstrap , 1994 .

[27]  Ayman I. Kayssi,et al.  Fuzzy reputation-based trust model , 2011, Appl. Soft Comput..

[28]  Arthur J. Miller,et al.  The Neuroscientific Principles of Swallowing and Dysphagia , 2000 .

[29]  J. Logemann,et al.  Pneumonia in Stroke Patients: A Retrospective Study , 2000, Dysphagia.

[30]  Sergio Cerutti,et al.  Entropy, entropy rate, and pattern classification as tools to typify complexity in short heart period variability series , 2001, IEEE Transactions on Biomedical Engineering.

[31]  Tom Chau,et al.  Vocalization removal for improved automatic segmentation of dual-axis swallowing accelerometry signals. , 2010, Medical engineering & physics.

[32]  Tom Chau,et al.  Effects of liquid stimuli on dual-axis swallowing accelerometry signals in a healthy population , 2010, Biomedical engineering online.

[33]  Tom Chau,et al.  Swallow segmentation with artificial neural networks and multi-sensor fusion. , 2009, Medical engineering & physics.