Morphology, topography, and optics of the orthokeratology cornea

Abstract. The goal of this work was to objectively characterize the external morphology, topography, and optics of the cornea after orthokeratology (ortho-k). A number of 24 patients between the ages of 17 and 30 years (median=24  years) were fitted with Corneal Refractive Therapy® contact lenses to correct myopia between −2.00 and −5.00 diopters (D) (median=−3.41  D). A classification algorithm was applied to conduct an automatic segmentation based on the mean local curvature. As a result, three zones (optical zone, transition zone, and peripheral zone) were delimited. Topographical analysis was provided through global and zonal fit to a general ellipsoid. Ray trace on partially customized eye models provided wave aberrations and retinal image quality. Monozone topographic description of the ortho-k cornea loses accuracy when compared with zonal description. Primary (C40) and secondary (C60) spherical aberration (SA) coefficients for a 5-mm pupil increased 3.68 and 19 times, respectively, after the treatments. The OZ area showed a strong correlation with C40 (r=−0.49, p<0.05) and a very strong correlation with C60 (r=0.78, p<0.01). The OZ, as well as the TZ, areas did not correlate with baseline refraction. The increase in the eye’s positive SA after ortho-k is the major factor responsible for the decreased retinal optical quality of the unaccommodated eye.

[1]  José Manuel González-Méijome,et al.  Peripheral Refraction in Myopic Patients After Orthokeratology , 2010, Optometry and vision science : official publication of the American Academy of Optometry.

[2]  J. Walline,et al.  Multifocal Contact Lens Myopia Control , 2013, Optometry and vision science : official publication of the American Academy of Optometry.

[3]  Marine Gobbe,et al.  Epithelial, Stromal, and Corneal Pachymetry Changes during Orthokeratology , 2009, Optometry and vision science : official publication of the American Academy of Optometry.

[4]  J. Robson,et al.  Application of fourier analysis to the visibility of gratings , 1968, The Journal of physiology.

[5]  H. Swarbrick,et al.  Central and Paracentral Corneal Curvature Changes During Orthokeratology , 2013, Optometry and vision science : official publication of the American Academy of Optometry.

[6]  Nicolas Chateau,et al.  Expanding depth of focus by modifying higher‐order aberrations induced by an adaptive optics visual simulator , 2009, Journal of cataract and refractive surgery.

[7]  A. Bradley,et al.  Modelling the effects of secondary spherical aberration on refractive error, image quality and depth of focus , 2015, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[8]  R. Legras,et al.  Effect of coma and spherical aberration on depth‐of‐focus measured using adaptive optics and computationally blurred images , 2012, Journal of cataract and refractive surgery.

[9]  Pauline Cho,et al.  The Performance of Four Different Corneal Topographers on Normal Human Corneas and Its Impact on Orthokeratology Lens Fitting , 2002, Optometry and vision science : official publication of the American Academy of Optometry.

[10]  K. Pesudovs,et al.  An analysis of the astigmatic changes induced by accelerated orthokeratology , 2002, Clinical & experimental optometry.

[11]  R. Navarro Refractive error sensing from wavefront slopes. , 2010, Journal of vision.

[12]  L. Thibos,et al.  Standards for reporting the optical aberrations of eyes. , 2002, Journal of refractive surgery.

[13]  Susana Marcos,et al.  Accommodative lag and fluctuations when optical aberrations are manipulated. , 2009, Journal of vision.

[14]  R. Navarro,et al.  Optics of the average normal cornea from general and canonical representations of its surface topography. , 2006, Journal of the Optical Society of America. A, Optics, image science, and vision.

[15]  M. Yaseri,et al.  Accommodative Changes After Photorefractive Keratectomy in Myopic Eyes , 2010, Optometry and Vision Science.

[16]  Objective refraction from aberrometry: theory. , 2009, Journal of biomedical optics.

[17]  A. Bradley,et al.  Retinal image quality during accommodation , 2013, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[18]  A. Nieto-Bona,et al.  Accommodative changes produced in response to overnight orthokeratology , 2015, Graefe's Archive for Clinical and Experimental Ophthalmology.

[19]  H. Price,et al.  Aberration control and vision training as an effective means of improving accommodation in individuals with myopia. , 2009, Investigative ophthalmology & visual science.

[20]  Norberto López-Gil,et al.  Modelling the impact of spherical aberration on accommodation , 2013, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[21]  D. G. Green,et al.  Optical and retinal factors affecting visual resolution. , 1965, The Journal of physiology.

[22]  R. Legras,et al.  Subjective depth of field in presence of 4th‐order and 6th‐order Zernike spherical aberration using adaptive optics technology , 2010, Journal of cataract and refractive surgery.

[23]  J. Robson,et al.  Spatial-frequency channels in human vision. , 1971, Journal of the Optical Society of America.

[24]  Paul Gifford,et al.  Can Manipulation of Orthokeratology Lens Parameters Modify Peripheral Refraction? , 2013, Optometry and vision science : official publication of the American Academy of Optometry.

[25]  Norberto López-Gil,et al.  The change of spherical aberration during accommodation and its effect on the accommodation response. , 2010, Journal of vision.

[26]  R. Navarro,et al.  Accommodation-dependent model of the human eye with aspherics. , 1985, Journal of the Optical Society of America. A, Optics and image science.

[27]  Norberto López-Gil,et al.  Spherical Aberration and the Sign of Defocus , 2013, Optometry and vision science : official publication of the American Academy of Optometry.

[28]  A. Bradley,et al.  Accuracy and precision of objective refraction from wavefront aberrations. , 2004, Journal of vision.

[29]  R. Navarro,et al.  Multizone model for postsurgical corneas: analysis of standard and custom LASIK outcomes. , 2008, Journal of biomedical optics.

[30]  A. Bradley,et al.  Predicting subjective judgment of best focus with objective image quality metrics. , 2004, Journal of vision.

[31]  J. Phillips,et al.  Effect of dual-focus soft contact lens wear on axial myopia progression in children. , 2011, Ophthalmology.

[32]  B. Koffler,et al.  Myopia control in children through refractive therapy gas permeable contact lenses: is it for real? , 2013, American journal of ophthalmology.

[33]  A. Guirao,et al.  A Method to Predict Refractive Errors from Wave Aberration Data , 2003, Optometry and vision science : official publication of the American Academy of Optometry.

[34]  L. Thibos Unresolved issues in the prediction of subjective refraction from wavefront aberration maps. , 2004, Journal of refractive surgery.

[35]  Luigina Sorbara,et al.  The relationship between the treatment zone diameter and visual, optical and subjective performance in Corneal Refractive Therapy™ lens wearers 1 , 2007, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[36]  C. Villa-Collar,et al.  Short-Term Changes in Light Distortion in Orthokeratology Subjects , 2015, BioMed research international.

[37]  C. Villa-Collar,et al.  Effect of pupil size on corneal aberrations before and after standard laser in situ keratomileusis, custom laser in situ keratomileusis, and corneal refractive therapy. , 2010, American journal of ophthalmology.

[38]  R. Navarro,et al.  Computing Retinal Contour from Optical Biometry , 2014, Optometry and vision science : official publication of the American Academy of Optometry.

[39]  J. González-Méijome,et al.  Subjective Satisfaction in Long-term Orthokeratology Patients , 2013, Eye & contact lens.

[40]  T. Chikama,et al.  Reversibility of Effects of Orthokeratology on Visual Acuity, Refractive Error, Corneal Topography, and Contrast Sensitivity , 2008, Eye & contact lens.