New Concepts of Quality Assurance in Analytical Chemistry: Will They Influence the Way We Conduct Science in General?

According to the guide Vocabulary in Metrology (VIM3) (JCGM, 2008), the definition of the concepts of trueness and accuracy has been revised, which has an important impact on analytical chemistry. Additionally, Eurachem/CITAC has published a new edition of the guide to Quantifying Uncertainty in Analytical Measurement (QUAM) (CITAC and Eurachem, 2012). These two documents, together, form a new basis for the evaluation of data. Results of prominent technologies of inductively coupled plasma mass spectrometry (ICP-MS), for determination of chloride-isotope ratios (35Cl/37Cl) and inductively coupled plasma optical emission spectrometry (ICP-OES) for determination of sodium, were evaluated in terms of the true level of uncertainty and revealed a genuine problem for science that was not addressed in VIM3 and QUAM. Comparison of theory and experimentation definitely requires statistical tools, but in contemporary science two approaches to the implementation of statistics in decision making are used: 1. Short-term precision and 2. long-term precision. Both approaches are valid and both are described using the same methods of statistics. However, they lead to completely different conclusions and decisions. Despite good intentions and new concepts, as well as practices and procedures for quality assurance, it is shown by these two examples that these efforts may be inadequate or mislead scientists into making major mistakes in the decision-making process. A set of equations is supplied, which are based on the propagation of uncertainty, and the implication of results and conclusions for other fields of science is discussed.

[1]  H. Drexler,et al.  Quality assurance of biological monitoring in occupational and environmental medicine. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[2]  Barry N. Taylor,et al.  The Current SI Seen From the Perspective of the Proposed New SI , 2011, Journal of research of the National Institute of Standards and Technology.

[3]  Mario Plebani,et al.  Errors in laboratory medicine. , 2002, Clinical chemistry.

[4]  Klaus Danzer,et al.  GUIDELINES FOR CALIBRATION IN ANALYTICAL CHEMISTRY , 1998 .

[5]  Paul De Bièvre About some basic concepts for metrology in analytical chemistry , 2012, Accreditation and Quality Assurance.

[6]  W. Horwitz,et al.  Evaluation of Analytical Methods Used for Regulation of Foods and Drugs , 1982 .

[7]  Piotr Konieczka,et al.  The Role of and the Place of Method Validation in the Quality Assurance and Quality Control (QA/QC) System , 2007 .

[8]  Lars Jorhem Certified reference materials as a quality tool in food control: much used—often misused—sometimes abused , 2004 .

[9]  P. De Bièvre,et al.  Atomic weights of the elements. Review 2000 (IUPAC Technical Report) , 2009 .

[10]  Filipe Medeiros Albano,et al.  Proficiency tests for laboratories: a systematic review , 2014, Accreditation and Quality Assurance.

[11]  Jens Enevold Thaulov Andersen,et al.  Pooled Calibrations and Retainment of Outliers Improved Chemical Analysis , 2012 .

[12]  B. P. Leonard The mole is an Avogadro number of entities, the macroscopic unit for chemical amount , 2014, Accreditation and Quality Assurance.

[13]  T. Coplen Atomic Weights of the Elements , 2003 .

[14]  J. Nóbrega,et al.  Application of the interference standard method for the determination of sulfur, manganese and iron in foods by inductively coupled plasma mass spectrometry. , 2011, Analytica chimica acta.

[15]  M. Cardinale,et al.  Method development for the determination of alkali metals in samples from pyrochemical reprocessing using ICP-OES and comparison with sector field ICP-MS , 2012 .

[16]  V. L. Dressler,et al.  Preparo de amostras de combustíveis fósseis por piroidrólise para a determinação de flúor e cloro , 2010 .

[17]  B Touati [Errors in the laboratory]. , 1982, Rivista italiana degli odontotecnici.

[18]  A. Eisenhauer,et al.  A simplified procedure for the determination of stable chlorine isotope ratios (δ37Cl) using LA-MC-ICP-MS , 2008 .

[19]  Manfred Reichenbächer,et al.  Solution to quality assurance challenge 11 , 2006, Analytical and Bioanalytical Chemistry.

[20]  J. Andersen Exercise in Quality Assurance: A Laboratory Exercise , 2009 .

[21]  Alex Williams,et al.  Principles of the EURACHEM/CITAC guide “Use of uncertainty information in compliance assessment” , 2008 .

[22]  Klaus Danzer,et al.  Guidelines for calibration in analytical chemistry. Part I. Fundamentals and single component calibration (IUPAC Recommendations 1998) , 1998 .

[23]  Gianfranco Genta,et al.  Features and performance of some outlier detection methods , 2011 .

[24]  Bertil Magnusson,et al.  Treatment of uncorrected measurement bias in uncertainty estimation for chemical measurements , 2008, Analytical and bioanalytical chemistry.

[25]  Jens Enevold Thaulov Andersen,et al.  On the development of quality assurance , 2014 .

[26]  James M. Harrington,et al.  Analysis of Human Serum and Whole Blood for Mineral Content by ICP-MS and ICP-OES: Development of a Mineralomics Method , 2014, Biological Trace Element Research.

[27]  W. Shotyk,et al.  Analytical procedures for the determination of selected major (Al, Ca, Fe, K, Mg, Na, and Ti) and trace (Li, Mn, Sr, and Zn) elements in peat and plant samples using inductively coupled plasma-optical emission spectrometry , 2005 .

[28]  S. Ellison,et al.  Quantifying uncertainty in analytical measurement , 2000 .

[29]  P. Szecsi,et al.  Error tracking in a clinical biochemistry laboratory , 2009, Clinical chemistry and laboratory medicine.

[30]  J. Andersen Determination of iron by Z-GFAAS and the influence of short-term precision and long-term precision , 2014 .