Near Real-Time Data Labeling Using a Depth Sensor for EMG Based Prosthetic Arms

Recognizing sEMG (Surface Electromyography) signals belonging to a particular action (e.g., lateral arm raise) automatically is a challenging task as EMG signals themselves have a lot of variation even for the same action due to several factors. To overcome this issue, there should be a proper separation which indicates similar patterns repetitively for a particular action in raw signals. A repetitive pattern is not always matched because the same action can be carried out with different time duration. Thus, a depth sensor (Kinect) was used for pattern identification where three joint angles were recording continuously which is clearly separable for a particular action while recording sEMG signals. To Segment out a repetitive pattern in angle data, MDTW (Moving Dynamic Time Warping) approach is introduced. This technique is allowed to retrieve suspected motion of interest from raw signals. MDTW based on DTW algorithm, but it will be moving through the whole dataset in a pre-defined manner which is capable of picking up almost all the suspected segments inside a given dataset an optimal way. Elevated bicep curl and lateral arm raise movements are taken as motions of interest to show how the proposed technique can be employed to achieve auto identification and labelling. The full implementation is available at this https URL

[1]  Carlo Frigo,et al.  Multichannel SEMG in clinical gait analysis: a review and state-of-the-art. , 2009, Clinical biomechanics.

[2]  M. Sangworasil,et al.  EMG signal feature extraction based on wavelet transform , 2010, ECTI-CON2010: The 2010 ECTI International Confernce on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology.

[3]  H B Boom,et al.  The median frequency of the surface EMG power spectrum in relation to motor unit firing and action potential properties. , 1992, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[4]  Chih-Jen Lin,et al.  A Practical Guide to Support Vector Classication , 2008 .

[5]  R. Vautard,et al.  Singular-spectrum analysis: a toolkit for short, noisy chaotic signals , 1992 .

[6]  Theocharis Kyriacou,et al.  Feasibility of using combined EMG and kinematic signals for prosthesis control: A simulation study using a virtual reality environment , 2016, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[7]  A. Izenman Linear Discriminant Analysis , 2013 .

[8]  A. Yli-Hankala,et al.  Time‐frequency balanced spectral entropy as a measure of anesthetic drug effect in central nervous system during sevoflurane, propofol, and thiopental anesthesia , 2004, Acta anaesthesiologica Scandinavica.

[9]  Hiroshi Yokoi,et al.  Shoulder joint control method for smart prosthetic arm based on surface EMG recognition , 2016, 2016 IEEE International Conference on Information and Automation (ICIA).

[10]  Hong Liu,et al.  EMG Control for a Five-fingered Underactuated Prosthetic Hand Based on Wavelet Transform and Sample Entropy , 2006, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[11]  M. Solomonow,et al.  Surface and wire EMG crosstalk in neighbouring muscles. , 1994, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[12]  Anatoly A. Zhigljavsky,et al.  Singular Spectrum Analysis for Time Series , 2013, International Encyclopedia of Statistical Science.

[13]  Mamun Bin Ibne Reaz,et al.  Surface Electromyography Signal Processing and Classification Techniques , 2013, Sensors.

[14]  Gernot R. Müller-Putz,et al.  Kinect-based detection of self-paced hand movements: Enhancing functional brain mapping paradigms , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[15]  Jérémy Frey Comparison of a consumer grade EEG amplifier with medical grade equipment in BCI applications , 2016 .

[16]  Donald J. Berndt,et al.  Using Dynamic Time Warping to Find Patterns in Time Series , 1994, KDD Workshop.

[17]  Rubita Sudirman,et al.  Features extraction of electromyography signals in time domain on biceps brachii muscle , 2013 .

[18]  Chenguang Yang,et al.  Human-machine interfaces based on EMG and Kinect applied to teleoperation of a mobile humanoid robot , 2012, Proceedings of the 10th World Congress on Intelligent Control and Automation.

[19]  Luca Benini,et al.  Analysis of Robust Implementation of an EMG Pattern Recognition based Control , 2014, BIOSIGNALS.

[20]  Hossein Hassani,et al.  Singular Spectrum Analysis: Methodology and Comparison , 2021, Journal of Data Science.

[21]  Christian Cipriani,et al.  Distance and mutual information methods for EMG feature and channel subset selection for classification of hand movements , 2016, Biomed. Signal Process. Control..

[22]  Carlo J. De Luca,et al.  The Use of Surface Electromyography in Biomechanics , 1997 .

[23]  Jason Farquhar,et al.  Singular spectrum analysis as a preprocessing filtering step for fNIRS brain computer interfaces , 2014, 2014 22nd European Signal Processing Conference (EUSIPCO).