Phase-Synchronized Assistive Torque Control for the Correction of Kinematic Anomalies in the Gait Cycle

Gait anomalies give rise to several clinical problems in stroke survivors, which restrict their functional mobility and have a negative impact on their quality of life. Robotics-aided gait training post-stroke has proven capable of improving patients’ functional walking, but so far it has not performed significantly better than conventional therapy. We hypothesize that an exoskeleton-based training program, aimed at correcting deficits in the leg joints’ movement, could produce greater improvements in gait function than conventional therapy. As a first step towards testing this hypothesis, we designed an exoskeleton control to correct a typical kinematic deficit post-stroke, namely, reduced knee flexion on the paretic side during swing. The proposed control attempts to minimize this deficit by delivering assistive torque synchronized with the continuous phase of the patient’s gait. Nine healthy male participants walked in a unilateral cable-driven exoskeleton while subject to an artificial knee flexion impairment produced by a custom-made knee brace. The experiments employed a treadmill featuring a variable-velocity control to allow self-selected gait speed. The artificial impairment by itself caused a significant reduction in peak flexion angle (p = 0.000129). Exoskeleton assistance compensated most of the knee flexion deficit, yielding no significant difference with unrestricted flexion (p = 0.3393). No significant changes in self-selected gait speed or stride frequency were detected. The proposed control can be expanded to correct motion deficits in other joints at different stages of the gait cycle.

[1]  S Moore,et al.  Observation and analysis of hemiplegic gait: swing phase. , 1993, The Australian journal of physiotherapy.

[2]  S Moore,et al.  Observation and analysis of hemiplegic gait: stance phase. , 1993, The Australian journal of physiotherapy.

[3]  Chung-Yao Kao,et al.  Control of Linear Time-Varying Systems Using Forward Riccati Equation , 1997 .

[4]  P O Riley,et al.  Hip hiking and circumduction: quantitative definitions. , 2000, American journal of physical medicine & rehabilitation.

[5]  B. Knowlton,et al.  Step training with body weight support: effect of treadmill speed and practice paradigms on poststroke locomotor recovery. , 2002, Archives of physical medicine and rehabilitation.

[6]  L. Ada,et al.  A treadmill and overground walking program improves walking in persons residing in the community after stroke: a placebo-controlled, randomized trial. , 2003, Archives of physical medicine and rehabilitation.

[7]  P. Tang,et al.  Analysis of impairments influencing gait velocity and asymmetry of hemiplegic patients after mild to moderate stroke. , 2003, Archives of physical medicine and rehabilitation.

[8]  D.J. Reinkensmeyer,et al.  Robot-enhanced motor learning: accelerating internal model formation during locomotion by transient dynamic amplification , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[9]  Roger Weber,et al.  Tools for understanding and optimizing robotic gait training. , 2006, Journal of rehabilitation research and development.

[10]  Frans C. T. van der Helm,et al.  A Series Elastic- and Bowden-Cable-Based Actuation System for Use as Torque Actuator in Exoskeleton-Type Robots , 2006, Int. J. Robotics Res..

[11]  D. Reinkensmeyer,et al.  Human-robot cooperative movement training: Learning a novel sensory motor transformation during walking with robotic assistance-as-needed , 2007, Journal of NeuroEngineering and Rehabilitation.

[12]  Chitralakshmi K. Balasubramanian,et al.  Relationship between step length asymmetry and walking performance in subjects with chronic hemiparesis. , 2007, Archives of physical medicine and rehabilitation.

[13]  F. Müller,et al.  Effects of Locomotion Training With Assistance of a Robot-Driven Gait Orthosis in Hemiparetic Patients After Stroke: A Randomized Controlled Pilot Study , 2007, Stroke.

[14]  Kelly P Westlake,et al.  Pilot study of Lokomat versus manual-assisted treadmill training for locomotor recovery post-stroke , 2009, Journal of NeuroEngineering and Rehabilitation.

[15]  D. Reisman,et al.  Split-Belt Treadmill Adaptation Transfers to Overground Walking in Persons Poststroke , 2009, Neurorehabilitation and neural repair.

[16]  Kara K. Patterson,et al.  Evaluation of gait symmetry after stroke: a comparison of current methods and recommendations for standardization. , 2010, Gait & posture.

[17]  S. K. Banala,et al.  Novel Gait Adaptation and Neuromotor Training Results Using an Active Leg Exoskeleton , 2010, IEEE/ASME Transactions on Mechatronics.

[18]  Nicola Vitiello,et al.  Oscillator-based assistance of cyclical movements: model-based and model-free approaches , 2011, Medical & Biological Engineering & Computing.

[19]  M. Molinari,et al.  Rehabilitation of gait after stroke: a review towards a top-down approach , 2011, Journal of NeuroEngineering and Rehabilitation.

[20]  Andrej Gams,et al.  On-line frequency adaptation and movement imitation for rhythmic robotic tasks , 2011, Int. J. Robotics Res..

[21]  Sunil K Agrawal,et al.  Effect of robotic performance-based error-augmentation versus error-reduction training on the gait of healthy individuals. , 2013, Gait & posture.

[22]  I. Campanini,et al.  A method to differentiate the causes of stiff-knee gait in stroke patients. , 2013, Gait & posture.

[23]  Jan Kool,et al.  A simple procedure to synchronize concurrent measurements of gait and brain electrical activity and preliminary results from a pilot measurement involving motor-cognitive dual-tasking in healthy older and young volunteers , 2014, Journal of Neuroscience Methods.

[24]  Meir Plotnik,et al.  Self-selected gait speed - over ground versus self-paced treadmill walking, a solution for a paradox , 2015, Journal of NeuroEngineering and Rehabilitation.

[25]  J. Higginson,et al.  Assist-as-Needed Robot-Aided Gait Training Improves Walking Function in Individuals Following Stroke , 2015, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[26]  Gregory S Sawicki,et al.  A neuromechanics-based powered ankle exoskeleton to assist walking post-stroke: a feasibility study , 2015, Journal of NeuroEngineering and Rehabilitation.

[27]  Tingfang Yan,et al.  Review of assistive strategies in powered lower-limb orthoses and exoskeletons , 2015, Robotics Auton. Syst..

[28]  Gabriel Aguirre-Ollinger,et al.  Exoskeleton control for lower-extremity assistance based on adaptive frequency oscillators: Adaptation of muscle activation and movement frequency , 2015, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[29]  Arun Jayaraman,et al.  Effects of a wearable exoskeleton stride management assist system (SMA®) on spatiotemporal gait characteristics in individuals after stroke: a randomized controlled trial , 2015, Journal of NeuroEngineering and Rehabilitation.

[30]  Dennis S. Bernstein,et al.  Infinite-Horizon Linear-Quadratic Control by Forward Propagation of the Differential Riccati Equation [Lecture Notes] , 2015, IEEE Control Systems.

[31]  Sheng-Che Yen,et al.  Using swing resistance and assistance to improve gait symmetry in individuals post-stroke. , 2015, Human movement science.

[32]  Herman van der Kooij,et al.  LOPES II—Design and Evaluation of an Admittance Controlled Gait Training Robot With Shadow-Leg Approach , 2016, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[33]  Rachel W Jackson,et al.  Human-in-the-loop optimization of exoskeleton assistance during walking , 2017, Science.

[34]  Andrea Parri,et al.  An oscillator-based smooth real-time estimate of gait phase for wearable robotics , 2016, Autonomous Robots.

[35]  Cordula Werner,et al.  Electromechanical-assisted training for walking after stroke. , 2017, The Cochrane database of systematic reviews.

[36]  Peng Qi,et al.  Gait-Event-Based Synchronization Method for Gait Rehabilitation Robots via a Bioinspired Adaptive Oscillator , 2017, IEEE Transactions on Biomedical Engineering.

[37]  Haoyong Yu,et al.  Exoskeleton Control for Post-stoke Gait Training of a Paretic Limb Based on Extraction of the Contralateral Gait Phase , 2018 .

[38]  Stefano Masiero,et al.  Electromyographic activity of the vastus intermedius muscle in patients with stiff-knee gait after stroke. A retrospective observational study. , 2017, Gait & posture.