Dual- and multi-energy CT: approach to functional imaging

The energy spectrum of X-ray photons after passage through an absorber contains information about its elemental composition. Thus, tissue characterisation becomes feasible provided that absorption characteristics can be measured or differentiated. Dual-energy CT uses two X-ray spectra enabling material differentiation by analysing material-dependent photo-electric and Compton effects. Elemental concentrations can thereby be determined using three-material decomposition algorithms. In comparison to dual-energy CT used in clinical practice, recently developed energy-sensitive photon-counting detectors sample the material-specific attenuation curves at multiple energy levels and within narrow energy bands; the latter allows the detection of element-specific, k-edge discontinuities of the photo-electric cross section. Multi-energy CT imaging therefore is able to concurrently identify multiple materials with increased accuracy. These specific data on material distribution provide information beyond morphological CT, and approach functional imaging. This article reviews the principles of dual- and multi-energy CT imaging, hardware approaches and clinical applications.

[1]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[2]  H. Genant,et al.  Quantitative bone mineral analysis using dual energy computed tomography. , 1977, Investigative radiology.

[3]  A. Macovski,et al.  Clinical application of Compton and photo-electric reconstruction in computed tomography: preliminary results. , 1978, Investigative radiology.

[4]  P. Joseph,et al.  Noise considerations in dual energy CT scanning. , 1979, Medical physics.

[5]  G. Chiro,et al.  Tissue signatures with dual-energy computed tomography. , 1979, Radiology.

[6]  W. Kalender,et al.  Evaluation of a prototype dual-energy computed tomographic apparatus. II. Determination of vertebral bone mineral content. , 1986, Medical physics.

[7]  W. Kalender,et al.  Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies. , 1986, Medical physics.

[8]  K. Stierstorfer,et al.  First performance evaluation of a dual-source CT (DSCT) system , 2006, European Radiology.

[9]  M. Reiser,et al.  Material differentiation by dual energy CT: initial experience , 2007, European Radiology.

[10]  A. Aschoff,et al.  Spectral Coronary Multidetector Computed Tomography Angiography: Dual Benefit by Facilitating Plaque Characterization and Enhancing Lumen Depiction , 2006, Journal of computer assisted tomography.

[11]  Borut Marincek,et al.  Dual-Energy Contrast-Enhanced Computed Tomography for the Detection of Urinary Stone Disease , 2007, Investigative radiology.

[12]  E. Roessl,et al.  K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors , 2007, Physics in medicine and biology.

[13]  James C. Williams,et al.  Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT. , 2007, Academic radiology.

[14]  Steven M Jorgensen,et al.  Quantitative X-Ray Imaging of Intraplaque Hemorrhage in Aortas of ApoE−/−/LDL−/− Double Knockout Mice , 2007, Investigative radiology.

[15]  Konstantin Nikolaou,et al.  Dual energy CT for the assessment of lung perfusion--correlation to scintigraphy. , 2008, European journal of radiology.

[16]  Mulugeta Gebregziabher,et al.  Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience , 2008, European Radiology.

[17]  C. McCollough,et al.  Dual-energy CT iodine-subtraction virtual unenhanced technique to detect urinary stones in an iodine-filled collecting system: a phantom study. , 2008, AJR. American journal of roentgenology.

[18]  M. Reiser,et al.  Dual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical Experience , 2008, Investigative radiology.

[19]  Ehsan Samei,et al.  Hypervascular liver tumors: low tube voltage, high tube current multi-detector row CT for enhanced detection--phantom study. , 2008, Radiology.

[20]  Joon Beom Seo,et al.  Xenon ventilation CT with a dual-energy technique of dual-source CT: initial experience. , 2008, Radiology.

[21]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[22]  Daniel T Boll,et al.  Coronary stent patency: dual-energy multidetector CT assessment in a pilot study with anthropomorphic phantom. , 2008, Radiology.

[23]  Hiroaki Naito,et al.  Dual-energy direct bone removal CT angiography for evaluation of intracranial aneurysm or stenosis: comparison with conventional digital subtraction angiography , 2009, European Radiology.

[24]  M. Macari,et al.  Dual energy CT: preliminary observations and potential clinical applications in the abdomen , 2008, European Radiology.

[25]  M. Reiser,et al.  Dual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical Experience , 2008, Investigative radiology.

[26]  Borut Marincek,et al.  Dual-energy computed tomography for the differentiation of uric acid stones: ex vivo performance evaluation , 2008, Urological Research.

[27]  U. Schoepf,et al.  Dual-energy CT of the heart--principles and protocols. , 2008, European journal of radiology.

[28]  Hersh Chandarana,et al.  Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms--initial observations. , 2008, Radiology.

[29]  J. Felblinger,et al.  Characterization of human renal stones with MDCT: advantage of dual energy and limitations due to respiratory motion. , 2008, AJR. American journal of roentgenology.

[30]  Borut Marincek,et al.  Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy. , 2008, European heart journal.

[31]  Borut Marincek,et al.  Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. , 2008, Radiology.

[32]  Zahi A Fayad,et al.  Nanotechnology in Medical Imaging: Probe Design and Applications , 2009, Arteriosclerosis, thrombosis, and vascular biology.

[33]  T. R. Melzer,et al.  Spectroscopic biomedical imaging with the Medipix2 detector , 2009, Australasian Physics & Engineering Sciences in Medicine.

[34]  Ernst Klotz,et al.  The assessment of intracranial bleeding with virtual unenhanced imaging by means of dual-energy CT angiography , 2009, European Radiology.

[35]  C. Claussen,et al.  Dual-energy CT for the characterization of urinary calculi: In vitro and in vivo evaluation of a low-dose scanning protocol , 2009, European Radiology.

[36]  J. Remy,et al.  Assessment of lobar perfusion in smokers according to the presence and severity of emphysema: preliminary experience with dual-energy CT angiography , 2009, European Radiology.

[37]  S. Ruehm,et al.  Dual-energy CT angiography of pelvic and lower extremity arteries: dual-energy bone subtraction versus manual bone subtraction. , 2009, Clinical radiology.

[38]  Hiroaki Naito,et al.  Dual-energy CT head bone and hard plaque removal for quantification of calcified carotid stenosis: utility and comparison with digital subtraction angiography , 2009, European Radiology.

[39]  Hatem Alkadhi,et al.  In vivo identification of uric acid stones with dual-energy CT: diagnostic performance evaluation in patients , 2010, Abdominal Imaging.

[40]  C. McCollough,et al.  Quantitative imaging of element composition and mass fraction using dual-energy CT: three-material decomposition. , 2009, Medical physics.

[41]  M. Reiser,et al.  Dual-energy CT for the assessment of contrast material distribution in the pulmonary parenchyma. , 2009, AJR. American journal of roentgenology.

[42]  E. Klotz,et al.  Carotid Computed Tomography Angiography With Automated Bone Suppression: A Comparative Study Between Dual Energy and Bone Subtraction Techniques , 2009, Investigative radiology.

[43]  D. Hough,et al.  Dual-energy and dual-source CT: is there a role in the abdomen and pelvis? , 2009, Radiologic clinics of North America.

[44]  C. McCollough,et al.  Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration. , 2009, Medical physics.

[45]  M. Reiser,et al.  The Value of Dual-Energy Bone Removal in Maximum Intensity Projections of Lower Extremity Computed Tomography Angiography , 2009, Investigative radiology.

[46]  K. Wolf,et al.  [Dual energy CT of the peripheral arteries: a phantom study to assess the effect of automatic plaque removal on stenosis grading]. , 2010, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[47]  Gerhard Martens,et al.  Focal cystic high-attenuation lesions: characterization in renal phantom by using photon-counting spectral CT--improved differentiation of lesion composition. , 2010, Radiology.

[48]  H. Alkadhi,et al.  Performance of dual-energy CT with tin filter technology for the discrimination of renal cysts and enhancing masses. , 2010, Academic radiology.

[49]  Peter Munk,et al.  Dual-energy CT as a potential new diagnostic tool in the management of gout in the acute setting. , 2010, AJR. American journal of roentgenology.

[50]  Elmar Kotter,et al.  Dual-energy CT virtual noncalcium technique: detecting posttraumatic bone marrow lesions--feasibility study. , 2010, Radiology.

[51]  M. Macari,et al.  Dual Source Dual Energy MDCT: Comparison of 80 kVp and Weighted Average 120 kVp Data for Conspicuity of Hypo-Vascular Liver Metastases , 2010, Investigative radiology.

[52]  M. Macari,et al.  Single-Phase Dual-Energy CT Allows for Characterization of Renal Masses as Benign or Malignant , 2010, Investigative radiology.

[53]  A. Butler,et al.  Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE , 2010, European Radiology.

[54]  Jin Peng,et al.  Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study , 2010, European Radiology.

[55]  Huiman X Barnhart,et al.  Dual-energy CT for characterization of adrenal nodules: initial experience. , 2010, AJR. American journal of roentgenology.

[56]  Borut Marincek,et al.  Characterization of Urinary Stones With Dual-Energy CT: Improved Differentiation Using a Tin Filter , 2010, Investigative radiology.

[57]  Xue Chai,et al.  Dual-energy CT angiography in the evaluation of intracranial aneurysms: image quality, radiation dose, and comparison with 3D rotational digital subtraction angiography. , 2010, AJR. American journal of roentgenology.