DR-BUDDI (Diffeomorphic Registration for Blip-Up blip-Down Diffusion Imaging) method for correcting echo planar imaging distortions

We propose an echo planar imaging (EPI) distortion correction method (DR-BUDDI), specialized for diffusion MRI, which uses data acquired twice with reversed phase encoding directions, often referred to as blip-up blip-down acquisitions. DR-BUDDI can incorporate information from an undistorted structural MRI and also use diffusion-weighted images (DWI) to guide the registration, improving the quality of the registration in the presence of large deformations and in white matter regions. DR-BUDDI does not require the transformations for correcting blip-up and blip-down images to be the exact inverse of each other. Imposing the theoretical "blip-up blip-down distortion symmetry" may not be appropriate in the presence of common clinical scanning artifacts such as motion, ghosting, Gibbs ringing, vibrations, and low signal-to-noise. The performance of DR-BUDDI is evaluated with several data sets and compared to other existing blip-up blip-down correction approaches. The proposed method is robust and generally outperforms existing approaches. The inclusion of the DWIs in the correction process proves to be important to obtain a reliable correction of distortions in the brain stem. Methods that do not use DWIs may produce a visually appealing correction of the non-diffusion weighted images, but the directionally encoded color maps computed from the tensor reveal an abnormal anatomy of the white matter pathways.

[1]  Stefan Skare,et al.  How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging , 2003, NeuroImage.

[2]  Mark Jenkinson,et al.  Reducing distortions in diffusion‐weighted echo planar imaging with a dual‐echo blip‐reversed sequence , 2010, Magnetic resonance in medicine.

[3]  Tzu-Chao Chuang,et al.  Correction of geometric distortion in Propeller echo planar imaging using a modified reversed gradient approach. , 2013, Quantitative imaging in medicine and surgery.

[4]  J. Michael Fitzpatrick,et al.  A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities , 1992, IEEE Trans. Medical Imaging.

[5]  Stefan Skare,et al.  A variational approach for the correction of field-inhomogeneities in EPI sequences , 2010, Medical Imaging.

[6]  F. Ye,et al.  Correction for geometric distortion and N/2 ghosting in EPI by phase labeling for additional coordinate encoding (PLACE) , 2007, Magnetic resonance in medicine.

[7]  Jan Sijbers,et al.  Susceptibility correction for improved tractography using high field DT-EPI , 2008, SPIE Medical Imaging.

[8]  Michael Unser,et al.  Unwarping of unidirectionally distorted EPI images , 2000, IEEE Transactions on Medical Imaging.

[9]  S. Skare,et al.  Correction of MR image distortions induced by metallic objects using a 3D cubic B‐spline basis set: Application to stereotactic surgical planning , 2005, Magnetic resonance in medicine.

[10]  Geoff J M Parker,et al.  Distortion correction for diffusion‐weighted MRI tractography and fMRI in the temporal lobes , 2010, Human brain mapping.

[11]  Carlo Pierpaoli,et al.  Effects of image distortions originating from susceptibility variations and concomitant fields on diffusion MRI tractography results , 2012, NeuroImage.

[12]  P. Basser,et al.  Estimation of the effective self-diffusion tensor from the NMR spin echo. , 1994, Journal of magnetic resonance. Series B.

[13]  J. Modersitzki,et al.  Diffeomorphic susceptibility artifact correction of diffusion-weighted magnetic resonance images , 2012, Physics in medicine and biology.

[14]  Michael I. Miller,et al.  Deformable templates using large deformation kinematics , 1996, IEEE Trans. Image Process..

[15]  Jianrong Shi,et al.  Toward a practical protocol for human optic nerve DTI with EPI geometric distortion correction , 2009, Journal of magnetic resonance imaging : JMRI.

[16]  Kalvis M. Jansons,et al.  Persistent angular structure: new insights from diffusion magnetic resonance imaging data , 2003 .

[17]  Ross T. Whitaker,et al.  A Variational Image-Based Approach to the Correction of Susceptibility Artifacts in the Alignment of Diffusion Weighted and Structural MRI , 2009, IPMI.

[18]  P. Basser,et al.  Comprehensive approach for correction of motion and distortion in diffusion‐weighted MRI , 2004, Magnetic resonance in medicine.

[19]  P. Basser,et al.  Diffusion tensor MR imaging of the human brain. , 1996, Radiology.

[20]  Sinisa Pajevic,et al.  Color schemes to represent the orientation of anisotropic tissues from diffusion tensor data: Application to white matter fiber tract mapping in the human brain , 1999, Magnetic resonance in medicine.

[21]  Diffusion Tensor Imaging at 3T with Strongly Reduced Geometric and Intensity Distortions , 2005 .

[22]  P. Reber,et al.  Correction of off resonance‐related distortion in echo‐planar imaging using EPI‐based field maps , 1998, Magnetic resonance in medicine.

[23]  Nikolaus Weiskopf,et al.  Correction of vibration artifacts in DTI using phase-encoding reversal (COVIPER) , 2012, Magnetic resonance in medicine.

[24]  P. Jezzard,et al.  Correction for geometric distortion in echo planar images from B0 field variations , 1995, Magnetic resonance in medicine.

[25]  Anders M. Dale,et al.  Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar Imaging , 2010, NeuroImage.

[26]  Raghu Machiraju,et al.  Susceptibility Distortion Correction for Echo Planar Images with Non-uniform B-Spline Grid Sampling: A Diffusion Tensor Image Study , 2011, MICCAI.

[27]  Steen Moeller,et al.  Advances in diffusion MRI acquisition and processing in the Human Connectome Project , 2013, NeuroImage.

[28]  Yiping P. Du,et al.  Correction of concomitant magnetic field‐induced image artifacts in nonaxial echo‐planar imaging , 2002, Magnetic resonance in medicine.

[29]  Brian B. Avants,et al.  Symmetric diffeomorphic image registration with cross-correlation: Evaluating automated labeling of elderly and neurodegenerative brain , 2008, Medical Image Anal..

[30]  Carlo Pierpaoli,et al.  Comparison of EPI Distortion Correction Methods in Diffusion Tensor MRI Using a Novel Framework , 2008, MICCAI.

[31]  Justin P Haldar,et al.  ACCELERATING DATA ACQUISITION FOR REVERSED-GRADIENT DISTORTION CORRECTION IN DIFFUSION MRI: A CONSTRAINED RECONSTRUCTION APPROACH , 2012 .

[32]  Rachid Deriche,et al.  Vector-valued image regularization with PDEs: a common framework for different applications , 2005, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[33]  Atle Bjørnerud,et al.  Correction of B0‐Distortions in Echo‐Planar‐Imaging–Based Perfusion‐Weighted MRI , 2014, Journal of magnetic resonance imaging : JMRI.

[34]  Daniel C. Alexander,et al.  Persistent Angular Structure: New Insights from Diffusion MRI Data. Dummy Version , 2003, IPMI.

[35]  Alan R. Moody,et al.  Correction of Distortion in ADC maps using the Reversed Gradient Method , 1999 .

[36]  D. Tuch Q‐ball imaging , 2004, Magnetic resonance in medicine.

[37]  C. Tempelmann,et al.  Eddy current correction in diffusion‐weighted imaging using pairs of images acquired with opposite diffusion gradient polarity , 2004, Magnetic resonance in medicine.

[38]  Paul A. Yushkevich,et al.  Deformable registration of diffusion tensor MR images with explicit orientation optimization , 2006, Medical Image Anal..

[39]  R. Bowtell,et al.  Correction of spatial distortion in EPI due to inhomogeneous static magnetic fields using the reversed gradient method , 2004, Journal of magnetic resonance imaging : JMRI.

[40]  Arno Klein,et al.  A reproducible evaluation of ANTs similarity metric performance in brain image registration , 2011, NeuroImage.

[41]  Mark W. Woolrich,et al.  Advances in functional and structural MR image analysis and implementation as FSL , 2004, NeuroImage.

[42]  D. Tuch High Angular Resolution Diffusion Imaging of the Human Brain , 1999 .

[43]  Robert Turner,et al.  Single-shot diffusion imaging at 2.0 tesla , 1990 .

[44]  L. Frank Characterization of anisotropy in high angular resolution diffusion‐weighted MRI , 2002, Magnetic resonance in medicine.

[45]  M. Horsfield,et al.  Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging , 1999, Magnetic resonance in medicine.

[46]  V. Wedeen,et al.  Mapping fiber orientation spectra in cerebral white matter with Fourier-transform diffusion MRI , 2000 .

[47]  D. Tuch Diffusion MRI of complex tissue structure , 2002 .