Current Harmonic Analysis of Multisampled LCLType Grid-connected Inverter

Multisampling control provides an attractive way to reduce the control delays in LCL-type grid-connected inverters, and thereby the bandwidth and stability margin will be improved. However, high frequency switching harmonics is introduced in the control loop when the inverter current is selected as a feedback. In order to investigate the effect of high frequency switching harmonics, the internal relationship between double-update pulse width modulation (PWM) and four-update PWM is deduced through the geometric analysis. Compared with the double-update PWM, a sampling instant is shifted a quarter of the switching period during each switching period. Hence the non-average value is sampled and low-order aliased harmonics will appear in the grid current. Finally, the theoretical analysis is verified through the simulation and experimental results.

[1]  Jesus Doval-Gandoy,et al.  Tuning Method Aimed at Optimized Settling Time and Overshoot for Synchronous Proportional-Integral Current Control in Electric Machines , 2014, IEEE Transactions on Power Electronics.

[2]  Zhang Xing,et al.  Implementation of multi-sampling current control for grid-connected inverters using TI TMS320F28377x , 2017, 2017 32nd Youth Academic Annual Conference of Chinese Association of Automation (YAC).

[3]  Frede Blaabjerg,et al.  Damping Methods for Resonances Caused by LCL-Filter-Based Current-Controlled Grid-Tied Power Inverters: An Overview , 2017, IEEE Transactions on Industrial Electronics.

[4]  R M Phelan,et al.  PSEUDO-DERIVATIVE-FEEDBACK (PDF) CONTROL. , 1971 .

[5]  P. Mattavelli,et al.  Analysis of Multisampled Current Control for Active Filters , 2007, IEEE Transactions on Industry Applications.

[6]  Shaojun Xie,et al.  Analysis and suppression of the aliasing in real-time sampling for grid-connected LCL-filtered inverters , 2016, 2016 IEEE 11th Conference on Industrial Electronics and Applications (ICIEA).

[7]  Igor Larrazabal,et al.  LCL Grid Filter Design of a Multimegawatt Medium-Voltage Converter for Offshore Wind Turbine Using SHEPWM Modulation , 2016, IEEE Transactions on Power Electronics.

[8]  Lin Jiang,et al.  Pseudo-Derivative-Feedback Current Control for Three-Phase Grid-Connected Inverters With LCL Filters , 2016, IEEE Transactions on Power Electronics.

[9]  Frede Blaabjerg,et al.  Overview of Multisampling Techniques in Power Electronics Converters , 2019, IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society.

[10]  J. Bocker,et al.  Can oversampling improve the dynamics of PWM controls? , 2013, 2013 IEEE International Conference on Industrial Technology (ICIT).

[11]  Xiaotian Zhang,et al.  Study of Multisampled Multilevel Inverters to Improve Control Performance , 2012, IEEE Transactions on Power Electronics.

[12]  Xing Zhang,et al.  Study of a Current Control Strategy Based on Multisampling for High-Power Grid-Connected Inverters With an LCL filter , 2017, IEEE Transactions on Power Electronics.