Spatial coherence of the nonlinearly generated second harmonic portion of backscatter for a clinical imaging system

Correlation-based approaches to phase aberration correction rely on the spatial coherence of backscattered signals. The spatial coherence of backscatter from speckle-producing targets is predicted by the auto correlation of the transmit apodization (Van Cittert-Zernike theorem). Work by others indicates that the second harmonic beam has a wider mainlobe with lower sidelobes than a beam transmitted at 2f. The purpose of this paper is to demonstrate that the spatial coherence of backscatter for the second harmonic is different from that of the fundamental, as would be anticipated from applying the Van Cittert-Zernike theorem to the reported measurements of the second harmonic field. Another objective of this work is to introduce the concept of the effective apodization and to verify that the effective apodization of the second harmonic is narrower than the transmit apodization. The spatial coherence of backscatter was measured using three clinical arrays with a modified clinical imaging system. The spatial coherence results were verified using a pseudo-array scan in a transverse plane of the transmitted field with a hydrophone. An effective apodization was determined by backpropagating these values using a linear angular spectrum approach. The spatial coherence for the harmonic portion of backscatter differed systematically and significantly from the auto correlation of the transmit apodization.

[1]  J. G. Miller,et al.  Interlaboratory comparison of ultrasonic backscatter, attenuation, and speed measurements. , 1999, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[2]  Gregg E. Trahey,et al.  In vivo comparison of fundamental and harmonic lateral transmit beam shapes , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[3]  B.D. Steinberg,et al.  Wavefront amplitude distortion and image sidelobe levels. II. In vivo experiments , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  S. W. Smith,et al.  Phase aberration correction in medical ultrasound using speckle brightness as a quality factor. , 1989, The Journal of the Acoustical Society of America.

[5]  G.E. Trahey,et al.  A comparative evaluation of several algorithms for phase aberration correction , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Raoul Mallart,et al.  The van Cittert–Zernike theorem in pulse echo measurements , 1991 .

[7]  T. Christopher,et al.  Source prebiasing for improved second harmonic bubble-response imaging , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  Yue Li Small element array algorithm for correcting phase aberration using near-field signal redundancy. I. Principles , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  R. Bates,et al.  Ultrasonic transmission speckle imaging. , 1981, Ultrasonic imaging.

[10]  I. Schnittger,et al.  Native tissue harmonic imaging improves endocardial border definition and visualization of cardiac structures. , 1998, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[11]  Spatial coherence analysis applied to aberration correction using a two-dimensional array system. , 2002, The Journal of the Acoustical Society of America.

[12]  Y Li,et al.  Phase aberration correction using near-field signal redundancy. I. Principles [Ultrasound medical imaging]. , 1997, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[13]  M. Averkiou,et al.  Tissue harmonic imaging , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[14]  R. Lang,et al.  Use of harmonic imaging without echocardiographic contrast to improve two-dimensional image quality. , 1998, The American journal of cardiology.

[15]  D Rachlin Direct estimation of aberrating delays in pulse-echo imaging systems. , 1990, The Journal of the Acoustical Society of America.

[16]  Peter A. Lewin,et al.  Transducer characterization using the angular spectrum method , 1989 .

[17]  J. S. Kim,et al.  Ultrasonographic evaluation of the gallbladder: comparison of fundamental, tissue harmonic, and pulse inversion harmonic imaging. , 2001, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[18]  B. Lüderitz,et al.  Improvement in Endocardial Border Delineation Using Tissue Harmonic Imaging , 1998, Echocardiography.

[19]  T. Christopher Finite amplitude distortion-based inhomogeneous pulse echo ultrasonic imaging , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  Shusou Wadaka,et al.  Incoherent ultrasonic imaging system , 1975 .

[21]  Peng Jiang,et al.  A new tissue harmonic imaging scheme with better fundamental frequency cancellation and higher signal-to-noise ratio , 1998, 1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102).

[22]  R. Shapiro,et al.  Tissue harmonic imaging sonography: evaluation of image quality compared with conventional sonography. , 1998, AJR. American journal of roentgenology.

[24]  J D Thomas,et al.  Qualitative and quantitative effects of harmonic echocardiographic imaging on endocardial edge definition and side-lobe artifacts. , 2000, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[25]  C. Burckhardt Speckle in ultrasound B-mode scans , 1978, IEEE Transactions on Sonics and Ultrasonics.

[26]  Kim C. Benjamin,et al.  Forward and backward projection of acoustic fields using FFT methods , 1981 .

[27]  Y Ogawa,et al.  The utility of tissue harmonic imaging in the liver: a comparison with conventional gray-scale sonography. , 2000, Oncology reports.

[28]  G E Trahey,et al.  Speckle coherence and implications for adaptive imaging. , 1997, The Journal of the Acoustical Society of America.

[29]  A closed loop ML algorithm for phase aberration correction in phased array imaging systems. I. Algorithm synthesis and experimental results [Ultrasound medical imaging] , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[30]  E.S. Ebbini,et al.  Blocked element compensation in phased array imaging , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[31]  R C Waag,et al.  Correction of ultrasonic wavefront distortion using backpropagation and a reference waveform method for time-shift compensation. , 1994, The Journal of the Acoustical Society of America.

[32]  P. H. Cittert,et al.  Die Wahrscheinliche Schwingungsverteilung in Einer von Einer Lichtquelle Direkt Oder Mittels Einer Linse Beleuchteten Ebene , 1934 .

[33]  M. Fink,et al.  Time reversal of ultrasonic fields. I. Basic principles , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[34]  Gregg E. Trahey,et al.  Adaptive imaging in the thyroid using fundamental and harmonic echo data , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).

[35]  M. O'Donnell,et al.  Suppression of propagating second harmonic in ultrasound contrast imaging , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[36]  Pai-Chi Li,et al.  Tissue harmonic image analysis based on spatial covariance. , 2001, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[37]  V F Humphrey,et al.  Nonlinear propagation in ultrasonic fields: measurements, modelling and harmonic imaging. , 2000, Ultrasonics.

[38]  R. F. Wagner,et al.  Statistics of Speckle in Ultrasound B-Scans , 1983, IEEE Transactions on Sonics and Ultrasonics.

[39]  Principles Li,et al.  Phase Aberration Correction Using Near-Field Signal Redundancy-Part I: , 1997 .

[40]  M. Hori,et al.  High-frame-rate tissue harmonic imaging enhances anatomic M-mode sections of the left ventricle in short-axis view. , 2000, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[41]  G. Steinbach,et al.  High-resolution harmonic gray-scale imaging of normal and abnormal vessels and tissues in animals. , 1998, Academic radiology.

[42]  K. Takamizawa,et al.  An investigation of wavefront distortion correction: correction using averaged phase information and the effect of correction in one and two dimensions (medical US imaging) , 1991, IEEE 1991 Ultrasonics Symposium,.

[43]  D.-L.D. Liu Element size effect on phase aberration correction , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[44]  J. Walkup,et al.  Statistical optics , 1986, IEEE Journal of Quantum Electronics.

[45]  C. Chin,et al.  Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[46]  M. O'Donnell,et al.  A phase aberration correction method for ultrasound imaging , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[47]  J D Thomas,et al.  Tissue harmonic imaging: why does it work? , 1998, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[48]  M. O’Donnell,et al.  Phase-aberration correction using signals from point reflectors and diffuse scatterers: basic principles , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[49]  A. C. Baker,et al.  Nonlinear propagation applied to the improvement of resolution in diagnostic medical ultrasound. , 1997, The Journal of the Acoustical Society of America.

[50]  F. Zernike The concept of degree of coherence and its application to optical problems , 1938 .

[51]  Takuso Sato,et al.  Imaging through an inhomogeneous layer by least‐mean‐square error fitting , 1984 .