The UF family of reference hybrid phantoms for computational radiation dosimetry

Computational human phantoms are computer models used to obtain dose distributions within the human body exposed to internal or external radiation sources. In addition, they are increasingly used to develop detector efficiencies for in vivo whole-body counters. Two classes of computational human phantoms have been widely utilized for dosimetry calculation: stylized and voxel phantoms that describe human anatomy through mathematical surface equations and 3D voxel matrices, respectively. Stylized phantoms are flexible in that changes to organ position and shape are possible given avoidance of region overlap, while voxel phantoms are typically fixed to a given patient anatomy, yet can be proportionally scaled to match individuals of larger or smaller stature, but of equivalent organ anatomy. Voxel phantoms provide much better anatomical realism as compared to stylized phantoms which are intrinsically limited by mathematical surface equations. To address the drawbacks of these phantoms, hybrid phantoms based on non-uniform rational B-spline (NURBS) surfaces have been introduced wherein anthropomorphic flexibility and anatomic realism are both preserved. Researchers at the University of Florida have introduced a series of hybrid phantoms representing the ICRP Publication 89 reference newborn, 15 year, and adult male and female. In this study, six additional phantoms are added to the UF family of hybrid phantoms-those of the reference 1 year, 5 year and 10 year child. Head and torso CT images of patients whose ages were close to the targeted ages were obtained under approved protocols. Major organs and tissues were segmented from these images using an image processing software, 3D-DOCTOR. NURBS and polygon mesh surfaces were then used to model individual organs and tissues after importing the segmented organ models to the 3D NURBS modeling software, Rhinoceros. The phantoms were matched to four reference datasets: (1) standard anthropometric data, (2) reference organ masses from ICRP Publication 89, (3) reference elemental compositions provided in ICRP 89 as well as ICRU Report 46, and (4) reference data on the alimentary tract organs given in ICRP Publications 89 and 100. Various adjustments and refinements to the organ systems of the previously described newborn, 15 year and adult phantoms are also presented. The UF series of hybrid phantoms retain the non-uniform scalability of stylized phantoms while maintaining the anatomical realism of patient-specific voxel phantoms with respect to organ shape, depth and inter-organ distance. While the final versions of these phantoms are in a voxelized format for radiation transport simulation, their primary format is given as NURBS and polygon mesh surfaces, thus permitting one to sculpt non-reference phantoms using the reference phantoms as an anatomic template.

[1]  Skeleton Keys: An Introduction to Human Skeletal, Morphology, Development and Analysis.. Jeffrey H. Schwartz Oxford University Press, New York, 1995. xi + 362 pp., figures, tables, appendixes, references, index. $49.95 (cloth). , 1997, American Antiquity.

[2]  W. Paul Segars,et al.  Patient-specific radiation dose and cancer risk estimation in pediatric chest CT: a study in 30 patients , 2010, Medical Imaging.

[3]  Wesley E Bolch,et al.  The UF series of tomographic computational phantoms of pediatric patients. , 2005, Medical physics.

[4]  W P Segars,et al.  Realistic CT simulation using the 4D XCAT phantom. , 2008, Medical physics.

[5]  D. Gentry Steele,et al.  The Anatomy and Biology of the Human Skeleton , 1988 .

[6]  James A. Scott Photon, Electron, Proton and Neutron Interaction Data for Body Tissues ICRU Report 46. International Commission on Radiation Units and Measurements, Bethesda, 1992, $40.00 , 1993 .

[7]  Wesley E Bolch,et al.  REVISIONS TO THE ORNL SERIES OF ADULT AND PEDIATRIC COMPUTATIONAL PHANTOMS FOR USE WITH THE MIRD SCHEMA , 2006, Health physics.

[8]  Habib Zaidi,et al.  Computational anthropomorphic models of the human anatomy: the path to realistic Monte Carlo modeling in radiological sciences. , 2007, Annual review of biomedical engineering.

[9]  K. F. Eckerman,et al.  Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn , 1987 .

[10]  T. Fell,et al.  An image-based skeletal tissue model for the ICRP reference newborn , 2009, Physics in medicine and biology.

[11]  P. Payne,et al.  Skin thickness measurement by pulsed ultrasound; its reproducibility, validation and variability , 1982, The British journal of dermatology.

[12]  W E Bolch,et al.  Creation of two tomographic voxel models of paediatric patients in the first year of life. , 2002, Physics in medicine and biology.

[13]  Icrp Assessing dose of the representative person for the purpose of radiation protection of the public , 2006 .

[14]  Division on Earth Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2 , 2006 .

[15]  Daniel Lodwick,et al.  Hybrid computational phantoms of the 15-year male and female adolescent: applications to CT organ dosimetry for patients of variable morphometry. , 2008, Medical physics.

[16]  M. Zankl,et al.  Influence of Patient Size on Organ Doses in Diagnostic Radiology , 1992 .

[17]  Chengyu Shi,et al.  A boundary-representation method for designing whole-body radiation dosimetry models: pregnant females at the ends of three gestational periods—RPI-P3, -P6 and -P9 , 2007, Physics in medicine and biology.

[18]  Perry B. Johnson,et al.  Hybrid computational phantoms for medical dose reconstruction , 2010, Radiation and environmental biophysics.

[19]  Wesley E. Bolch,et al.  Hybrid Patient-Dependent Phantoms Covering Statistical Distributions of Body Morphometry in the U.S. Adult and Pediatric Population , 2009, Proceedings of the IEEE.

[20]  Martin Caon,et al.  Voxel-based computational models of real human anatomy: a review , 2004, Radiation and Environmental Biophysics.

[21]  Martin Caon,et al.  Monte Carlo Calculated Effective Dose to Teenage Girls from Computed Tomography Examinations , 2000 .

[22]  Wesley E Bolch,et al.  Whole-body voxel phantoms of paediatric patients—UF Series B , 2006, Physics in medicine and biology.

[23]  C. Potter ICRP Publication 100 Human Alimentary Tract Model for Radiological Protection. , 2007 .

[24]  Ehsan Samei,et al.  Patient-specific dose estimation for pediatric chest CT. , 2008, Medical physics.

[25]  J. Valentin Basic anatomical and physiological data for use in radiological protection: reference values , 2002, Annals of the ICRP.

[26]  Wesley E. Bolch,et al.  An Algorithm for Lymphatic Node Placement in Hybrid Computational Phantoms—Applications to Radionuclide Therapy Dosimetry , 2009, Proceedings of the IEEE.

[27]  Deanna Hasenauer,et al.  Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models , 2007, Physics in medicine and biology.