Braille dot display module with a PDMS membrane driven by a thermopneumatic actuator

Abstract A new type of a Braille dot display module is proposed and evaluated with a poly-dimethylsiloxane (PDMS) membrane driven by a thermopneumatic actuator for six-dot Braille code. Each module consists of four parts: a PDMS reservoir chamber for the working fluid (3M PF-5060), a working fluid, a PDMS membrane (3 mm × 3 mm), and a resistive micro-heater. The module is insulated against the generated heat and allows interoperability with other modules. The deflections of PDMS membranes of different thicknesses, 42, 23, and 15 μm, are observed while changing the input power to the resistive micro-heater in the range of 0.75–2.5 W. The maximum deflections of PDMS membranes with thicknesses of 42, 23, and 15 μm are about 1.37, 1.34, and 1.28 mm, respectively, over the substrates at 0.75 W, and slightly decrease to about 1.32, 1.30, and 1.23 mm, respectively, at 2.5 W. However, the time required to reach maximum deflection differes greatly with increasing power. At 0.75 W, the response times are 97, 49, and 45 s, respectively. While at 2.5 W, the times are shortened by 16, 14, and 13 s, respectively. The achieved deflection is larger than two times of the standard height (600 μm) designated by the Blind Union in Korea.

[1]  Seung S. Lee,et al.  Focal tunable liquid lens integrated with an electromagnetic actuator , 2007 .

[2]  Dong-Soo Kwon,et al.  Perceptual and biomechanical frequency response of human skin: implication for design of tactile displays , 2005, First Joint Eurohaptics Conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. World Haptics Conference.

[3]  Mark R. Rosenzweig,et al.  Biological Psychology: an introduction to behavioral and cognitive neuroscience / Mark R. Rosenzweig,S. Marc Breedlove, Neil V. Watson , 2005 .

[4]  D. Durand,et al.  A novel integrable microvalve for refreshable Braille display system , 2003 .

[5]  Chang Liu,et al.  Re-configurable fluid circuits by PDMS elastomer micromachining , 1999, Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291).

[6]  Mami Tanaka,et al.  Development of a tactile sensor system for reading Braille: fundamental characteristics of the prototype sensor system , 2005 .

[7]  Bruce C. Towe,et al.  A thermopneumatic dispensing micropump , 2004 .

[8]  Willis J. Tompkins,et al.  A 64-Solenoid, Four-Level Fingertip Search Display for the Blind , 1987, IEEE Transactions on Biomedical Engineering.

[9]  Shuichi Takayama,et al.  Multiplexed hydraulic valve actuation using ionic liquid filled soft channels and Braille displays , 2007 .

[10]  J. G. Linvill,et al.  Cylindrical PVF2 electromechanical transducers , 1981 .

[11]  P. M. Taylor,et al.  A sixty-four element tactile display using shape memory alloy wires , 1998 .

[12]  P. M. Taylor,et al.  Advances in an electrorheological fluid based tactile array , 1998 .

[13]  Y. Jaluria,et al.  An Introduction to Heat Transfer , 1950 .

[14]  Jaedo Nam,et al.  Braille display device using soft actuator , 2004, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[15]  Satoshi Konishi,et al.  Fabrication and drive test of pneumatic PDMS micro pump , 2007 .

[16]  Fung-Huei Yeh,et al.  Mechanism design of the flapper actuator in Chinese Braille display , 2007 .

[17]  Hyuk-Jun Kwon,et al.  Braille code display device with a PDMS membrane and thermopneumatic actuator , 2008, 2008 IEEE 21st International Conference on Micro Electro Mechanical Systems.