Biomechanical analysis of scapular neck malunion--a simulation study.

OBJECTIVE To explain loss of shoulder function following scapular neck malunion in terms of biomechanical changes around the gleno-humeral joint. DESIGN Biomechanical modelling study. BACKGROUND Residual rotation of the scapular neck after fracture can lead to pain and loss of function, and the indications for surgical intervention are contested. METHODS A 3D, large-scale, musculo-skeletal model of the upper limb was used to compare shoulder biomechanics in the case of scapular neck malunion with normal anatomy. Abduction of the humerus was simulated with three models: normal anatomy, 24 degrees and 40 degrees inferior scapular neck rotation. RESULTS Predicted muscle activation differed greatly between the control and the fracture cases. The motion required additional muscle effort for the maintenance of gleno-humeral stability in the fracture cases. Higher moments in the plane of abduction were generated by the teres major, pectoralis major and biceps brachii muscles with high humeral elevation angles. The rotator cuff muscles were severely shortened in the post-fracture cases and the forces in these muscles were greatly reduced in a test of loaded abduction with the humerus at 90 degrees. CONCLUSIONS Given the function of the rotator cuff muscles as stabilisers of the gleno-humeral joint, it is concluded that the loss of force in these muscles, together with other changes in muscle activation, will lead to loss of arm function in patients with scapular neck malunion. RELEVANCE These findings will contribute to the improved treatment of patients with scapular neck malunion by identifying important factors in the consideration of surgical intervention.

[1]  Piet M. Rozing,et al.  Influence of glenohumeral prosthesis geometry and placement on shoulder muscle forces. , 1996 .

[2]  R. Churchill,et al.  Glenoid size, inclination, and version: an anatomic study. , 2001, Journal of shoulder and elbow surgery.

[3]  M. Miller,et al.  Scapular fractures. Analysis of 113 cases. , 1991, Clinical orthopaedics and related research.

[4]  A. Lam,et al.  Results of fixation of clavicle alone in managing floating shoulder. , 2000, Singapore medical journal.

[5]  F. V. D. van der Helm,et al.  Effectiveness of tendon transfers for massive rotator cuff tears: a simulation study. , 2004, Clinical biomechanics.

[6]  R. Marti,et al.  The floating shoulder. A multicentre study. , 2001, The Journal of bone and joint surgery. British volume.

[7]  Maurice E. Müller,et al.  Manual of Internal Fixation: Techniques Recommended by the AO Group , 1979 .

[8]  A. Imhoff,et al.  Scapular neck fracture – the influence of permanent malalignment of the glenoid neck on clinical outcome , 2001, Archives of Orthopaedic and Trauma Surgery.

[9]  C. Spoor,et al.  Measuring muscle and joint geometry parameters of a shoulder for modeling purposes. , 1999, Journal of biomechanics.

[10]  A. M. Acosta,et al.  of the 23 rd Annual EMBS International Conference , October 25-28 , Istanbul , Turkey MODEL-BASED DEVELOPMENT OF NEUROPROSTHESES FOR RESTORING PROXIMAL ARM FUNCTION , 2004 .

[11]  J. W. van der Spuy,et al.  The fractured scapula: importance and management based on a series of 62 patients. , 1984, Injury.

[12]  P. Regazzoni,et al.  The Unstable Shoulder Girdle: Early Functional Treatment Utilizing Open Reduction and Internal Fixation , 1995, Journal of orthopaedic trauma.

[13]  F.C.T. van der Helm,et al.  A finite element musculoskeletal model of the shoulder mechanism. , 1994 .

[14]  H E Veeger,et al.  Quasi-static analysis of muscle forces in the shoulder mechanism during wheelchair propulsion. , 1996, Journal of biomechanics.

[15]  Paul H. C. Eilers,et al.  Flexible smoothing with B-splines and penalties , 1996 .

[16]  L. A. Rozendaal,et al.  Load on the shoulder in low intensity wheelchair propulsion. , 2002, Clinical biomechanics.