Precision and accuracy of acoustospectrographic parameters.

Theoretical estimates of the standard deviation (STD) of four acoustospectrographic parameters (the intercept and slope of attenuation and backscatter coefficient) are derived. This derivation expands and corrects existing derivations, and is confirmed using simulations based on the adopted theoretical model. A robust parameter estimation method is applied to various phantom measurements, and to in vivo liver scans of healthy human subjects. The measured STD is higher than the theoretically predicted value, and we investigated four possible factors which explain this discrepancy. First, it is shown that the STD and bias after spectrogram calculation are rather insensitive to changes in windowing function, type, length and overlap. Second, we observed that a diffraction correction spectrogram calibrated on a medium different from the one being measured insufficiently corrects the depth-dependency of the parameters, which affects both precision as well as accuracy. We therefore propose a method that constructs an organ-specific diffraction correction spectrogram from the averaged spectrogram of a set of normal organs. We show that the organ-specific correction does not affect STD even in case of previously unseen acquisitions. Third, we introduce local inhomogeneity, which predicts excess STD due to local variations of the physical parameters within an organ (i.e., intrasubject), and global inhomogeneity, which predicts variations between organs (i.e., intersubject). We conclude that our method of estimating STD predicts normal, in vivo data very well, and propose that the deviation from these estimates is a potential tissue characterization parameter.

[1]  Optimal precision in ultrasound attenuation estimation and application to the detection of Duchenne muscular dystrophy carriers. , 1987, Ultrasonic imaging.

[2]  R. L. Romijn,et al.  Ultrasound attenuation and texture analysis of diffuse liver disease: methods and preliminary results. , 1991, Physics in medicine and biology.

[3]  C. Burckhardt Speckle in ultrasound B-mode scans , 1978, IEEE Transactions on Sonics and Ultrasonics.

[4]  D E Robinson,et al.  Beam pattern (diffraction) correction for ultrasonic attenuation measurement. , 1984, Ultrasonic imaging.

[5]  Johan M. Thijssen,et al.  Diffraction and Dispersion Effects on the Estimation of Ultrasound Attenuation and Velocity in Biological Tissues , 1985, IEEE Transactions on Biomedical Engineering.

[6]  Yasuhiko Ozawa,et al.  Spectral analysis of echoes for backscattering coefficient measurement , 1985 .

[7]  Michael Insana,et al.  Improvements in the Spectral Difference Method for Measuring Ultrasonic Attenuation , 1983, Ultrasonic imaging.

[8]  J Perrin,et al.  Diffraction correction for focused transducers in attenuation measurements in vivo. , 1987, Ultrasonic imaging.

[9]  E. Feleppa,et al.  Theoretical framework for spectrum analysis in ultrasonic tissue characterization. , 1983, The Journal of the Acoustical Society of America.

[10]  E. Feleppa,et al.  Relationship of Ultrasonic Spectral Parameters to Features of Tissue Microstructure , 1987, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  P. Welch The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms , 1967 .

[12]  D. Kleinbaum,et al.  Applied Regression Analysis and Other Multivariate Methods , 1978 .

[13]  R. Kuc Bounds on estimating the acoustic attenuation of small tissue regions from reflected ultrasound , 1985, Proceedings of the IEEE.

[14]  Athanasios Papoulis,et al.  Probability, Random Variables and Stochastic Processes , 1965 .

[15]  A. P. Berkhoff,et al.  Simulation of ultrasonic imaging with linear arrays in causal absorptive media. , 1996, Ultrasound in medicine & biology.

[16]  R. Kuc,et al.  Variation of acoustic attenuation coefficient slope estimates for in vivo liver. , 1982, Ultrasound in medicine & biology.

[17]  E. Madsen,et al.  Method of data reduction for accurate determination of acoustic backscatter coefficients. , 1984, The Journal of the Acoustical Society of America.

[18]  Matthew O'Donnell,et al.  Effects of Diffraction on Measurements of the Frequency-Dependent Ultrasonic Attenuation , 1983, IEEE Transactions on Biomedical Engineering.

[19]  Mathias Fink,et al.  Ultrasonic Signal Processing for in Vivo Attenuation Measurement: Short Time Fourier Analysis , 1983 .

[20]  D. Nicholas,et al.  Evaluation of backscattering coefficients for excised human tissues: Principles and techniques , 1982 .

[21]  J M Thijssen,et al.  A general model for the absorption of ultrasound by biological tissues and experimental verification. , 1986, The Journal of the Acoustical Society of America.

[22]  J. Goodman Statistical Properties of Laser Speckle Patterns , 1963 .

[23]  R. F. Wagner,et al.  Statistics of Speckle in Ultrasound B-Scans , 1983, IEEE Transactions on Sonics and Ultrasonics.

[24]  R. Mountford,et al.  Ultrasonic liver scanning: the quantitative analysis of the normal A-scan. , 1972, Physics in medicine and biology.

[25]  H. Schwan,et al.  Mechanism of absorption of ultrasound in liver tissue. , 1971, The Journal of the Acoustical Society of America.

[26]  L. X. Yao,et al.  Statistical uncertainty in ultrasonic backscatter and attenuation coefficients determined with a reference phantom. , 1991, Ultrasound in medicine & biology.

[27]  K. Parker Attenuation measurement uncertainties caused by speckle statistics. , 1986, The Journal of the Acoustical Society of America.

[28]  M.F. Insana,et al.  Backscatter coefficient estimation using array transducers , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[29]  Mitsuhiro Ueda,et al.  The effect of windowing on spectral estimation of echoes scattered by a random medium , 1988 .

[30]  R A Lerski,et al.  A simple tissue-like ultrasound phantom material. , 1982, The British journal of radiology.

[31]  I Céspedes,et al.  Diffraction correction methods for pulse-echo acoustic attenuation estimation. , 1990, Ultrasound in medicine & biology.

[32]  R. L. Romijn,et al.  Estimation of scatterer size from backscattered ultrasound: a simulation study , 1989, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[33]  R. Kuc,et al.  Parametric Estimation of the Acoustic Attenuation Coefficient Slope for Soft Tissue , 1976 .

[34]  R. Kuc,et al.  Estimating the Acoustic Attenuation Coefficient Slope for Liver from Reflected Ultrasound Signals , 1979, IEEE Transactions on Sonics and Ultrasonics.

[35]  J M Thijssen,et al.  A beam corrected estimation of the frequency dependent attenuation of biological tissues from backscattered ultrasound. , 1983, Ultrasonic imaging.

[36]  F Lizzi,et al.  Applications of spectral analysis in medical ultrasonography. , 1976, Ultrasonics.