A micro opto-mechanical displacement sensor based on micro-diffraction gratings: Design and characterization

A micro opto-mechanical displacement sensor is here presented. It is constituted by a sensing element based on two overlapped micro-diffraction gratings (MDGs). They present a platinum layer (45 nm of thick) on a glass substrate, a period of 525 μm constituted by a width of 150 μm of platinum separated (71.4% duty cycle). The working principle is based on the modulation of light intensity induced by the relative displacement between the MDGs: when a laser light perpendicularly hits the MDGs, the intensity of the transmitted light is a periodic function of the relative displacement between the two MDGs. A fiber optic is used to transport the transmitted light to a photodetector in order to avoid concerns related to the alignment between the optical components. The sensor's output is the ratio between the light intensity measured by the photodetector during the displacement of the MDGs and largest light intensity values measured in the whole range of measurement, therefore, it is lower than 1. The proposed sensor allows to discriminate displacement lower than 10 μm, using a cost effective micro-fabrication process implemented by the technique of Lift-Off. It shows a good linear behaviour in two ranges covering about one half of the MDGs period. Within the linear ranges it shows high sensitivity (about 0.5%/μm) and good accuracy (lower than 4 % in the whole range of calibration); furthermore, the results show that a design with a duty cycle of 50 % overcomes the marked decrease of sensitivity in a range of measurement corresponding to a grating period.

[1]  James H. Smith,et al.  Micromachined pressure sensors: review and recent developments , 1997 .

[2]  Sergio Silvestri,et al.  A novel target-type low pressure drop bidirectional optoelectronic air flow sensor for infant artificial ventilation: measurement principle and static calibration. , 2011, The Review of scientific instruments.

[3]  D L Polla,et al.  Microdevices in medicine. , 2000, Annual review of biomedical engineering.

[4]  Sergio Silvestri,et al.  An optical fiber based flow transducer for infant ventilation: Measurement principle and calibration , 2011, 2011 IEEE International Symposium on Medical Measurements and Applications.

[5]  Sergio Silvestri,et al.  Optical-Fiber Measurement Systems for Medical Applications , 2011 .

[6]  R. W. Bernstein,et al.  Micromachined silicon force sensor based on diffractive optical encoders for characterization of microinjection , 2004 .

[7]  M. Schmidt,et al.  Microfabrication in biology and medicine. , 1999, Annual review of biomedical engineering.

[8]  A micro flow-meter for closed-loop management of biological samples , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[9]  Sergio Silvestri,et al.  A micromachined intensity-modulated fiber optic sensor for strain measurements: Working principle and static calibration , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  Olivier Parriaux,et al.  A silicon integrated opto-electro-mechanical displacement sensor , 2004 .

[11]  Sergio Silvestri,et al.  A high sensitivity fiber optic macro-bend based gas flow rate transducer for low flow rates: theory, working principle, and static calibration. , 2013, The Review of scientific instruments.

[12]  Sergio Silvestri,et al.  Micromachined Flow Sensors in Biomedical Applications , 2012, Micromachines.

[13]  Giorgio C. Buttazzo,et al.  Design of a variable impedance differential actuator for wearable robotics applications , 2010, 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[14]  Nevio Luigi Tagliamonte,et al.  Double actuation architectures for rendering variable impedance in compliant robots: A review , 2012 .