Fast functional brain imaging using constrained reconstruction based on regularization using arbitrary projections

This work describes a novel method for highly undersampled projection imaging using constrained reconstruction by Tikhonov‐Phillips regularization and its application for high temporal resolution functional MRI (fMRI) at a repetition time of 80 ms. The high‐resolution reference image used as in vivo coil sensitivity is acquired in a separate acquisition using otherwise identical parameters. Activation studies using a standard checkerboard activation paradigm demonstrate the inherent high sensitivity afforded by the possibility to separate activation‐related effects from “physiological noise.”. In this first proof‐of‐principle of the constrained reconstruction based on regularization using arbitrary projections (COBRA) technique, experiments are performed in a single‐slice mode, which allows for a comparison with fast single‐slice echo‐planar imaging (EPI) at equal temporal resolution. The COBRA method can be extended to three‐dimensional (3D) encoding without severe penalty in temporal performance. Analysis of the global signal change demonstrates the excellent reproducibility of COBRA compared to standard EPI. Activation analysis is considerably improved by the possibility to remove electrocardiogram (ECG)‐related and breathing‐related signal fluctuations by physiological correction of each individual breathing and ECG cycle, respectively. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.

[1]  M. Hestenes,et al.  Methods of conjugate gradients for solving linear systems , 1952 .

[2]  David L. Phillips,et al.  A Technique for the Numerical Solution of Certain Integral Equations of the First Kind , 1962, JACM.

[3]  A Tikhonov,et al.  Solution of Incorrectly Formulated Problems and the Regularization Method , 1963 .

[4]  V. F. Sears Slow-neutron inelastic scattering in absorbing media with application to liquid 3He , 1976 .

[5]  Peter Mansfield,et al.  Planar spin imaging by NMR , 1976 .

[6]  D. Tank,et al.  Brain magnetic resonance imaging with contrast dependent on blood oxygenation. , 1990, Proceedings of the National Academy of Sciences of the United States of America.

[7]  J W Belliveau,et al.  Functional cerebral imaging by susceptibility‐contrast NMR , 1990, Magnetic resonance in medicine.

[8]  R M Weisskoff,et al.  Simple measurement of scanner stability for functional NMR imaging of activation in the brain , 1996, Magnetic resonance in medicine.

[9]  W. Manning,et al.  Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.

[10]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[11]  G H Glover,et al.  Image‐based method for retrospective correction of physiological motion effects in fMRI: RETROICOR , 2000, Magnetic resonance in medicine.

[12]  G. Glover,et al.  Physiological noise in oxygenation‐sensitive magnetic resonance imaging , 2001, Magnetic resonance in medicine.

[13]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[14]  Walter F Block,et al.  Time‐resolved contrast‐enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory , 2002, Magnetic resonance in medicine.

[15]  Klaas P Pruessmann,et al.  Encoding and reconstruction in parallel MRI , 2006, NMR in biomedicine.

[16]  J Velikina,et al.  Highly constrained backprojection for time‐resolved MRI , 2006, Magnetic resonance in medicine.

[17]  Matti S Hämäläinen,et al.  Dynamic magnetic resonance inverse imaging of human brain function , 2006, Magnetic resonance in medicine.

[18]  K. T. Block,et al.  Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint , 2007, Magnetic resonance in medicine.

[19]  Oliver Speck,et al.  MR-Encephalography: Fast multi-channel monitoring of brain physiology with magnetic resonance , 2007, NeuroImage.

[20]  Lawrence L. Wald,et al.  Event-related single-shot volumetric functional magnetic resonance inverse imaging of visual processing , 2008, NeuroImage.

[21]  Thomas Witzel,et al.  Linear constraint minimum variance beamformer functional magnetic resonance inverse imaging , 2008, NeuroImage.