Helium-cooled, refractory heat exchangers are now under consideration for first wall and divertor applications. These refractory devices take advantage of high temperature operation with large delta-Ts to effectively handle high heat fluxes. The high temperature helium can then be used in a gas turbine for high-efficiency power conversion. Over the last five years, heat removal with helium was shown to increase dramatically by using porous metal to provide a very large effective surface area for heat transfer in a small volume. Last year, the thermal performance of a bare-copper, dual-channel, helium-cooled, porous metal divertor mock-up was evaluated on the 30 kW Electron Beam Test System at Sandia National Laboratories. The module survived a maximum absorbed heat flux of 34.6 MW/m2 and reached a maximum surface temperature of 593 °C for uniform power loading of 3 kW absorbed on a 2-cm2 area. An impressive 10 kW of power was absorbed on an area of 24 cm2. Recently, a similar dual-module, helium-cooled heat exchanger made almost entirely of tungsten was designed and fabricated by Thermacore, Inc. and tested at Sandia. A complete flow test of each channel was performed to determine the actual pressure drop characteristics. Each channel was equipped with delta-P transducers and platinum resistance temperature devices (RTDs) for independent calorimetry. One mass flow meter monitored the total flow to the heat exchanger, while a second monitored flow in only one of the channels. The thermal response of each tungsten module was obtained for heat fluxes in excess of 5 MW/m2 using 50 °C helium at 4 MPa. Fatigue cycles were also performed to assess the fracture toughness of the tungsten modules. A description of the module design and new results on flow instabilities are also presented.
[1]
Mark T. North,et al.
Thermal performance and flow instabilities in a multi-channel, helium-cooled, porous metal divertor module
,
2000
.
[2]
J. Rosenfeld,et al.
Evaluation of porous media heat exchangers for plasma facing components
,
1993,
15th IEEE/NPSS Symposium. Fusion Engineering.
[3]
J. M. McDonald,et al.
High heat flux testing capabilities at Sandia National Laboratories - New Mexico
,
1994
.
[4]
C. B. Baxi,et al.
High-Heat-Flux Testing of Helium-Cooled Heat Exchangers for Fusion Applications
,
1996
.
[5]
Mark T. North,et al.
Test results from a helium gas-cooled porous metal heat exchanger
,
1996,
Optics & Photonics.
[6]
Ralph W. Moir,et al.
On the exploration of innovative concepts for fusion chamber technology
,
2001
.