Mapping chemicals in air using an environmental CAT scanning system: evaluation of algorithms

Abstract A new technique is being developed which creates near real-time maps of chemical concentrations in air for environmental and occupational environmental applications. This technique, we call Environmental CAT Scanning, combines the real-time measuring technique of open-path Fourier transform infrared spectroscopy with the mapping capabilitites of computed tomography to produce two-dimensional concentration maps. With this system, a network of open-path measurements is obtained over an area; measurements are then processed using a tomographic algorithm to reconstruct the concentrations. This research focussed on the process of evaluating and selecting appropriate reconstruction algorithms, for use in the field, by using test concentration data from both computer simultation and laboratory chamber studies. Four algorithms were tested using three types of data: (1) experimental open-path data from studies that used a prototype opne-path Fourier transform/computed tomography system in an exposure chamber; (2) synthetic open-path data generated from maps created by kriging point samples taken in the chamber studies (in 1), and; (3) synthetic open-path data generated using a chemical dispersion model to create time seires maps. The iterative algorithms used to reconstruct the concentration data were: Algebraic Reconstruction Technique without Weights (ART1), Algebraic Reconstruction Technique with Weights (ARTW), Maximum Likelihood with Expectation Maximization (MLEM) and Multiplicative Algebraic Reconstruction Technique (MART). Maps were evaluated quantitatively and qualitatively. In general, MART and MLEM performed best, followed by ARTW and ART1. However, algorithm performance varied under different contaminant scenarios. This study showed the importance of using a variety of maps, particulary those generated using dispersion models. The time series maps provided a more rigorous test of the algorithms and allowed distinctions to be made among the algorithms. A comprehensive evaluation of algorithms, for the environmental application of tomography, requires the use of a battery of test concentration data before field implementation, which models reality and tests the limits of the algorithms.

[1]  Robert L. Byer,et al.  Air pollution monitoring by computed tomography , 1979, COMPSAC.

[2]  R L Byer,et al.  Two-dimensional remote air-pollution monitoring via tomography. , 1979, Optics letters.

[3]  Lori A. Todd,et al.  Mapping air contaminants indoors using a prototype computed tomography system , 1996 .

[4]  William W. Nazaroff,et al.  Novel approach for tomographic reconstruction of gas concentration distributions in air: Use of smooth basis functions and simulated annealing , 1996 .

[5]  L A Todd,et al.  Spatial and temporal visualization of gases and vapours in air using computed tomography. Numerical studies. , 1997, The Annals of occupational hygiene.

[6]  Eric C. Frey,et al.  Comparison between ML-EM and WLS-CG algorithms for SPECT image reconstruction , 1991 .

[7]  P. Griffiths Fourier Transform Infrared Spectrometry , 2007 .

[8]  P. D. Rowley,et al.  Quantitative interpretation of three- dimensional weakly refractive phase objects using holographic interferometry , 1969 .

[9]  G. Herman,et al.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. , 1970, Journal of theoretical biology.

[10]  G. Hounsfield Computerized transverse axial scanning (tomography): Part I. Description of system. 1973. , 1973, The British journal of radiology.

[11]  James G. Sanderson Reconstruction of Fuel Pin Bundles by a Maximum Entropy Method , 1979, IEEE Transactions on Nuclear Science.

[12]  Steven R. Hanna,et al.  Handbook on atmospheric diffusion , 1982 .

[13]  M. Berry,et al.  The interpretation of optical projections , 1970, Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences.

[14]  D. J. De Rosier,et al.  Reconstruction of Three Dimensional Structures from Electron Micrographs , 1968, Nature.

[15]  S P Levine,et al.  Imaging indoor tracer-gas concentrations with computed tomography: experimental results with a remote sensing FTIR system. , 1994, American Industrial Hygiene Association journal.

[16]  R L Byer,et al.  Model studies of laser absorption computed tomography for remote air pollution measurement. , 1982, Applied optics.

[17]  M I Reis,et al.  Maximum entropy algorithms for image reconstruction from projections , 1992 .

[18]  David Leith,et al.  Remote Sensing and Computed Tomography in Industrial Hygiene , 1990 .

[19]  L. Todd,et al.  Evaluation of algorithms for tomographic reconstruction of chemical concentrations in indoor air. , 1994, American Industrial Hygiene Association journal.

[20]  L A Todd,et al.  Tomographic reconstruction of air pollutants: evaluation of measurement geometries. , 1997, Applied optics.