A Low-Cost, High-Performance System for Fluorescence Lateral Flow Assays

We demonstrate a fluorescence lateral flow system that has excellent sensitivity and wide dynamic range. The illumination system utilizes an LED, plastic lenses and plastic and colored glass filters for the excitation and emission light. Images are collected on an iPhone 4. Several fluorescent dyes with long Stokes shifts were evaluated for their signal and nonspecific binding in lateral flow. A wide range of values for the ratio of signal to nonspecific binding was found, from 50 for R-phycoerythrin (R-PE) to 0.15 for Brilliant Violet 605. The long Stokes shift of R-PE allowed the use of inexpensive plastic filters rather than costly interference filters to block the LED light. Fluorescence detection with R-PE and absorbance detection with colloidal gold were directly compared in lateral flow using biotinylated bovine serum albumen (BSA) as the analyte. Fluorescence provided linear data over a range of 0.4–4,000 ng/mL with a 1,000-fold signal change while colloidal gold provided non-linear data over a range of 16–4,000 ng/mL with a 10-fold signal change. A comparison using human chorionic gonadotropin (hCG) as the analyte showed a similar advantage in the fluorescent system. We believe our inexpensive yet high-performance platform will be useful for providing quantitative and sensitive detection in a point-of-care setting.

[1]  Min-Gon Kim,et al.  A dual gold nanoparticle conjugate-based lateral flow assay (LFA) method for the analysis of troponin I. , 2010, Biosensors & bioelectronics.

[2]  Geertruida A. Posthuma-Trumpie,et al.  Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey , 2009, Analytical and bioanalytical chemistry.

[3]  M. Maheshwari,et al.  Rapid Point-of-Care Testing for Detection of HIV and Clinical Monitoring , 2013, ISRN AIDS.

[4]  E. Ooi,et al.  Diagnosis of dengue: an update , 2012, Expert review of anti-infective therapy.

[5]  Gildas Morvan,et al.  A literature survey , 2013 .

[6]  Jens Michaelis,et al.  Enhancement of the detection limit for lateral flow immunoassays: evaluation and comparison of bioconjugates. , 2012, Journal of immunological methods.

[7]  Feng Yan,et al.  Biomedical and clinical applications of immunoassays and immunosensors for tumor markers , 2007 .

[8]  Aydogan Ozcan,et al.  Albumin testing in urine using a smart-phone. , 2013, Lab on a chip.

[9]  Ying Wang,et al.  Rapid and sensitive detection of protein biomarker using a portable fluorescence biosensor based on quantum dots and a lateral flow test strip. , 2010, Analytical chemistry.

[10]  Xiliang Wang,et al.  Development and application of lateral flow test strip technology for detection of infectious agents and chemical contaminants: a review , 2010, Analytical and bioanalytical chemistry.

[11]  J. Jacobs,et al.  Assessment of the prozone effect in malaria rapid diagnostic tests , 2009, Malaria Journal.

[12]  Hongying Zhu,et al.  Optofluidic fluorescent imaging cytometry on a cell phone. , 2011, Analytical chemistry.

[13]  Dan Du,et al.  Quantum dot-based immunochromatographic fluorescent biosensor for biomonitoring trichloropyridinol, a biomarker of exposure to chlorpyrifos. , 2010, Analytical chemistry.

[14]  Shizhi Qian,et al.  A mathematical model of lateral flow bioreactions applied to sandwich assays. , 2003, Analytical biochemistry.

[15]  Reinhard Renneberg,et al.  Development of a quantitative lateral-flow assay for rapid detection of fatty acid-binding protein. , 2003, Journal of immunological methods.

[16]  Tero Soukka,et al.  Performance of fluorescent europium(III) nanoparticles and colloidal gold reporters in lateral flow bioaffinity assay. , 2012, Analytical biochemistry.

[17]  R. Miano,et al.  Evaluation of a new, rapid, qualitative, one-step PSA Test for prostate cancer screening: the PSA RapidScreen test , 2005, Prostate Cancer and Prostatic Diseases.

[18]  Aydogan Ozcan,et al.  Integrated rapid-diagnostic-test reader platform on a cellphone. , 2012, Lab on a chip.

[19]  S. Blacksell,et al.  Commercial Dengue Rapid Diagnostic Tests for Point-of-Care Application: Recent Evaluations and Future Needs? , 2012, Journal of biomedicine & biotechnology.

[20]  L. Rickman,et al.  RAPID DIAGNOSIS OF MALARIA , 1989, The Lancet.

[21]  Hervé Volland,et al.  A fluorescent immunochromatographic test using immunoliposomes for detecting microcystins and nodularins , 2010, Analytical and bioanalytical chemistry.

[22]  C. Happi,et al.  Recrudescent Plasmodium falciparum infections in children in an endemic area following artemisinin–based combination treatments: Implications for disease control , 2011 .