Tracking time-varying properties of the systemic vascular bed

The problem of tracking changes in viscoelastic properties of the systemic arterial bed is considered, and a recursive estimation procedure, belonging to the class of output-error algorithms with adjustable compensator, is developed and discussed. By means of computer simulation, suitable values are determined for the key design variable which controls the tradeoff between the tracking ability and noise sensitivity of the algorithm. In this way, the algorithm allows online estimation of arterial compliance, peripheral resistance, and characteristic impedance on the basis of aortic pressure and flow signals. The results obtained from data numerically simulated, as well as measured on a mock circulatory system, demonstrate that the dominant arterial time constant can be tracked by the algorithm using only measurements of the aortic pressure during diastole.<<ETX>>

[1]  B. Deswysen,et al.  Parameter Estimation of a Simple Model of the Left Ventricle and of the Systemic Vascular Bed, with Particular Attention to the Physical Meaning of the Left Ventricular Parameters , 1977, IEEE Transactions on Biomedical Engineering.

[2]  S M Finkelstein,et al.  Vascular hemodynamic impedance measurement. , 1982, Progress in cardiovascular diseases.

[3]  Ioan Doré Landau,et al.  Recursive output error identification algorithms theory and evaluation , 1980, Autom..

[4]  Guido Avanzolini,et al.  Model selection and parameter estimation for aortic input impedance , 1984 .

[5]  Abraham Noordergraaf,et al.  Reduced Models of Arterial Systems , 1985, IEEE Transactions on Biomedical Engineering.

[6]  W S Pierce,et al.  Mechanical support of the circulation followed by cardiac transplantation. , 1986, The Journal of thoracic and cardiovascular surgery.

[7]  Swamy Laxminarayan,et al.  Characterization of the Arterial System in the Time Domain , 1978, IEEE Transactions on Biomedical Engineering.

[8]  B. Wilcox,et al.  Comparison of time domain algorithms for estimating aortic characteristic impedance in humans , 1988, IEEE Transactions on Biomedical Engineering.

[9]  John R. Glover,et al.  Adaptive Control of Blood Pressure , 1983, IEEE Transactions on Biomedical Engineering.

[10]  B. McInnis,et al.  Adaptive control of left ventricular bypass assist devices , 1985 .

[11]  Guido Avanzolini,et al.  A Versatile Identification Method Applied to Analysis of Respiratory Mechanics , 1984, IEEE Transactions on Biomedical Engineering.

[12]  O. Frank,et al.  Die grundform des arteriellen pulses , 1899 .

[13]  Guido Avanzolini,et al.  A Comparative Evaluation of Three On-Line Identification Methods for Respiratory Mechanical Model , 1985, IEEE Transactions on Biomedical Engineering.

[14]  J T Watson,et al.  Clinical temporary ventricular assist. Pathologic findings and their implications in a multi-institutional study of 41 patients. , 1986, The Journal of thoracic and cardiovascular surgery.

[15]  Antti J. Koivo,et al.  Microprocessor-based controller for pharmacodynamical applications , 1981 .

[16]  R L Kormos,et al.  Temporary use of the Jarvik-7 total artificial heart before transplantation. , 1987, The New England journal of medicine.

[17]  Dov Jaron,et al.  Engineering Techniques Applied to the Analysis and Control of In-Series Cardiac Assistance , 1984, IEEE Transactions on Biomedical Engineering.