Characterizing corrosion behavior under atmospheric conditions using electrochemical techniques

Abstract AC and DC electrochemical experiments were performed as a function of humidity and contaminant concentration in an effort to identify the range of atmospheric environments where corrosion processes could be detected and possibly quantified. AC measurements exhibited two time constants at 25% relative humidity (RH), possibly indicating the ability to resolve both electrolyte resistance and interfacial impedance. Galvanic current measurements were sensitive to the presence of Cl 2(g) at 30% RH and electrochemical transients were detected at both 30% and 50% RH levels, also indicating sensitivity to interfacial processes. Higher humidity levels allowed better quantification due to decreasing electrolyte and interfacial impedances.

[1]  W. Jia Electrochemical measurements for marine atmospheric corrosion studies using Kelvin probe reference electrode , 1996 .

[2]  V. Kučera,et al.  Practical Experience with an Electrochemical Technique for Atmospheric Corrosion Monitoring , 1981 .

[3]  Atsushi Nishikata,et al.  Pitting corrosion mechanism of stainless steels under wet-dry exposure in chloride-containing environments , 1998 .

[4]  F. Mansfeld Monitoring of Atmospheric Corrosion Phenomena with Electrochemical Sensors , 1988 .

[5]  Atsushi Nishikata,et al.  Electrochemical corrosion monitoring of galvanized steel under cyclic wet–dry conditions , 2000 .

[6]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[7]  A. Baró,et al.  Study of Water Droplets and Films on Graphite by Noncontact Scanning Force Microscopy , 1999 .

[8]  Masahiro Yamamoto,et al.  Relationship between corrosion rate of carbon steel and water film thickness under thin layer of artificial sea water , 2001 .

[9]  V. Foglietti,et al.  Investigations on the response to humidity of an interdigitated electrode structure coated with iodine doped polyphenylacetylene , 1996 .

[10]  Masahiro Yamamoto,et al.  Continuous Corrosion Rate Measurement of Carbon Steel in Outdoor Environment Using AC-Impedance Method , 2001 .

[11]  J. Bastidas,et al.  Electrochemical Sensors for Atmospheric Corrosion Rates: A New Design , 1984 .

[12]  Atsushi Nishikata,et al.  An application of electrochemical impedance spectroscopy to atmospheric corrosion study , 1995 .

[13]  Florian Mansfeld,et al.  Laboratory studies of atmospheric corrosion—I. Weight loss and electrochemical measurements , 1980 .

[14]  P. Sereda Atmospheric Factors Affecting the Corrosion of Steel , 1960 .

[15]  F. Mansfeld Evaluation of electrochemical techniques for monitoring of atmospheric corrosion phenomena , 1981 .

[16]  P. Wynblatt,et al.  Water Adsorption and Surface Conductivity Measurements on alpha -Alumina Substrates , 1987 .

[17]  A. Nishikata,et al.  AC impedance study on corrosion of 55%Al-Zn alloy-coated steel under thin electrolyte layers , 2000 .

[18]  L. Flett Industrial and Engineering Chemistry - "Dyestuff Industry" , 1951 .

[19]  V. Zhdanov,et al.  Nucleation and island growth during water adsorption at submonolayer coverages , 1995 .

[20]  The role of water vapour in the corrosion of microelectronic circuits , 1977 .

[21]  Wataru Oshikawa,et al.  Fractal behavior of galvanic current of dual electrode type of atmospheric corrosion monitor , 1999 .

[22]  Atsushi Nishikata,et al.  Electrochemical studies on corrosion under a water film , 1995 .

[23]  Hidesato Mabuchi,et al.  An electrochemical impedance study on atmospheric corrosion of steels in a cyclic wet-dry condition , 1995 .

[24]  M. Saitou Scaling Approach to Galvanic Current of Stainless Steel/Silver Atmospheric Corrosion Monitor , 2000 .

[25]  K. McLean,et al.  The effect of adsorbed gases on the surface conductivity of quartz , 1977 .

[26]  Atsushi Nishikata,et al.  Corrosion Monitoring of Zn and Zn–Al Coated Steels under Wet-Dry Cyclic Conditions Using AC Impedance Method , 1997 .

[27]  Christofer Leygraf Atmospheric corrosion , 2000 .