Corrosion and Strength Behaviors in Prestressed Tendon under Various Tensile Stress and Impressed Current Conditions

Corrosion occurs more rapidly under high tensile stress and this leads to several problems like degradation of serviceability and structural performance in PSC (prestressed concrete) structures. In this paper, impressed current method, so-called ICM, was applied to tendons under tensile loadings of 0.0, 20.0, 40.0, and 60.0% of ultimate load. With induction of 20 volts for 24 hours to tendon under tensile stress, loading was induced to failure and the ultimate load was evaluated with varying corrosion behaviors. The changing mechanical behaviors in the same corrosive conditions were evaluated under different initial prestressing levels. With increasing initial prestressing load, corrosion occurred more rapidly and corrosion amount also increased linearly. The ultimate load accordingly decreased with increasing initial prestressing and corrosion amount. The relationships between prestressing levels and corrosion behaviors were quantitatively obtained through regression analysis. The measured current during applied voltage and the related corrosion amounts were also dealt with in this work.

[1]  Lei Wang,et al.  A global model for corrosion-induced cracking in prestressed concrete structures , 2016 .

[2]  Seung-Jun Kwon,et al.  Non Destructive Technique for Steel Corrosion Detection Using Heat Induction and IR Thermography , 2012 .

[3]  Claudio Mazzotti Design of a concrete structure , 2013 .

[4]  Walter Podolny,et al.  CORROSION OF PRESTRESSING STEELS AND ITS MITIGATION , 1992 .

[5]  Shan-Tung Tu,et al.  In situ monitoring on prestress losses in the reinforced structure with fiber-optic sensors , 2009 .

[6]  Yingshu Yuan,et al.  Corrosion propagation of prestressing steel strands in concrete subject to chloride attack , 2011 .

[7]  Sun-Kyu Cho,et al.  Acoustic Emission Technique for Detection of Corrosion-Induced Wire Fracture , 2005 .

[8]  Wallace T McKeel,et al.  DETECTION OF DELAMINATION IN BRIDGE DECKS WITH INFRARED THERMOGRAPHY , 1978 .

[9]  Feng Xing,et al.  Long-term monitoring of reinforcement corrosion in concrete using ground penetrating radar , 2017 .

[10]  Sang Hyo Kim,et al.  Reliability Evaluation of a PSC Highway Bridge Based on Resistance Capacity Degradation Due to a Corrosive Environment , 2016 .

[11]  Genda Chen,et al.  A Smart Steel Strand for the Evaluation of Prestress Loss Distribution in Post-tensioned Concrete Structures , 2009 .

[12]  Maria Q. Feng,et al.  Nondestructive Corrosion Detection in RC Through Integrated Heat Induction and IR Thermography , 2012, Journal of Nondestructive Evaluation.

[13]  Rj Woodward,et al.  COLLAPSE OF YNS-Y-GWAS BRIDGE, GLAMORGAN. , 1988 .

[14]  Yingshu Yuan,et al.  Effects of corrosion on bond behavior between steel strand and concrete , 2013 .

[15]  Antje Strauss,et al.  Corrosion Of Steel In Concrete Understanding Investigation And Repair , 2016 .