Achieving Commutation Control of an MRI-Powered Robot Actuator

Actuators that are powered, imaged, and controlled by magnetic resonance (MR) scanners could inexpensively provide wireless control of MR-guided robots. Similar to traditional electric motors, the MR scanner acts as the stator and generates propulsive torques on an actuator rotor containing one or more ferrous particles. Generating maximum motor torque while avoiding instabilities and slippage requires closed-loop control of the electromagnetic field gradients, i.e., commutation. Accurately estimating the position and velocity of the rotor is essential for high-speed control, which is a challenge due to the low refresh rate and high latency associated with MR signal acquisition. This paper proposes and demonstrates a method for closed-loop commutation based on interleaving pulse sequences for rotor imaging and rotor propulsion. This approach is shown to increase motor torque and velocity, eliminate rotor slip, and enable regulation of rotor angle. Experiments with a closed-loop MR imaging actuator produced a maximum force of 9.4 N.

[1]  John M Pauly,et al.  Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles , 2005, Magnetic resonance in medicine.

[2]  Franziska Ullrich,et al.  Mobility experiments with microrobots for minimally invasive intraocular surgery. , 2013, Investigative ophthalmology & visual science.

[3]  Murat Cenk Cavusoglu,et al.  Three dimensional modeling of an MRI actuated steerable catheter system , 2014, 2014 IEEE International Conference on Robotics and Automation (ICRA).

[4]  Kostas E. Bekris,et al.  Visual and force-feedback guidance for robot-assisted interventions in the beating heart with real-time MRI , 2012, 2012 IEEE International Conference on Robotics and Automation.

[5]  Pierre E. Dupont,et al.  MRI-powered actuators for robotic interventions , 2011, 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[6]  Christos Yiallouras,et al.  MRI-compatible positioning device for guiding a focused ultrasound system for transrectal treatment of prostate cancer , 2014, International Journal of Computer Assisted Radiology and Surgery.

[7]  D. Caleb Rucker,et al.  A MRI-guided concentric tube continuum robot with piezoelectric actuation: A feasibility study , 2012, 2012 IEEE International Conference on Robotics and Automation.

[8]  S. Posse,et al.  Susceptibility artifacts in spin-echo and gradient-echo imaging , 1990 .

[9]  Gábor Székely,et al.  MRI driven magnetic microswimmers , 2012, Biomedical microdevices.

[10]  Jake J. Abbott,et al.  Magnetic Guidance of Cochlear Implants: Proof-of-Concept and Initial Feasibility Study , 2012 .

[11]  D. Beyersdorff,et al.  MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: initial results. , 2005, Radiology.

[12]  S. Misra,et al.  Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies , 2011, European Radiology.

[13]  Pierre E. Dupont,et al.  Closed-loop commutation control of an MRI-powered robot actuator , 2013, 2013 IEEE International Conference on Robotics and Automation.

[14]  Stephen B. Solomon,et al.  MRI-Safe Robot for Endorectal Prostate Biopsy , 2014, IEEE/ASME Transactions on Mechatronics.

[15]  Metin Sitti,et al.  Design and Rolling Locomotion of a Magnetically Actuated Soft Capsule Endoscope , 2012, IEEE Transactions on Robotics.

[16]  Sylvain Martel,et al.  Method of propulsion of a ferromagnetic core in the cardiovascular system through magnetic gradients generated by an MRI system , 2006, IEEE Transactions on Biomedical Engineering.

[17]  Sylvain Martel,et al.  Adapting the clinical MRI software environment for real‐time navigation of an endovascular untethered ferromagnetic bead for future endovascular interventions , 2008, Magnetic resonance in medicine.

[18]  Pierre E. Dupont,et al.  Tracking and position control of an MRI-powered needle-insertion robot , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[19]  Sukho Park,et al.  Novel electromagnetic actuation system for three-dimensional locomotion and drilling of intravascular microrobot , 2010 .

[20]  J.M. Santos,et al.  Flexible real-time magnetic resonance imaging framework , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[21]  Vaughan R. Pratt,et al.  Direct least-squares fitting of algebraic surfaces , 1987, SIGGRAPH.

[22]  T. Podder,et al.  In vivo motion and force measurement of surgical needle intervention during prostate brachytherapy. , 2006, Medical physics.

[23]  Aaron Becker,et al.  Simultaneously powering and controlling many actuators with a clinical MRI scanner , 2014, 2014 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[24]  Pierre E. Dupont,et al.  An MRI-powered and controlled actuator technology for tetherless robotic interventions , 2013, Int. J. Robotics Res..

[25]  P. Dario,et al.  Magnetic propulsion and ultrasound tracking of endovascular devices , 2012, Journal of Robotic Surgery.

[26]  Zion Tsz Ho Tse,et al.  Prospective motion correction using tracking coils , 2013, Magnetic resonance in medicine.

[27]  Robert Trampel,et al.  Method for automatic localization of MR‐visible markers using morphological image processing and conventional pulse sequences: Feasibility for image‐guided procedures , 2007, Journal of magnetic resonance imaging : JMRI.

[28]  M. Moche,et al.  Simultaneous 3D localization of multiple MR-visible markers in fully reconstructed MR images: proof-of-concept for subsecond position tracking. , 2012, Magnetic Resonance Imaging.

[29]  Peter Kazanzides,et al.  Robotic needle guide for prostate brachytherapy: clinical testing of feasibility and performance. , 2011, Brachytherapy.