Biomechanical assessment of the aortic root using novel force transducers.

In recent years the use of valve sparing techniques has become more common in selected patients with aortic valve insufficiency. However, limited experimental research has been performed to document the biomechanical effect of these techniques. One experimental platform is to evaluate how the normal physiological aortic root forces are altered or re-established after the surgical intervention. Hence, the aim of this project was to develop new implantable force transducers for a biomechanical description of various aortic root repair techniques. Two novel force transducers were developed. Both transducers were manufactured using rapid prototyping and were instrumented with miniature strain gauges. Before implantation both transducers were calibrated using a dedicated setup, yielding very linear correlation between the applied load and transducer output. The developed force transducers were implanted and tested in an 80kg porcine model. In the post-cardioplegic heart, the peak annular forces varied in the range of 2-4N and the commissural forces varied from 0.4 to 0.8N with a left ventricular pressure of 111mmHg. In conclusion, the two new force transducers to measure forces in the aortic root have successfully been developed. With these new devices a novel versatile and direct force measurement system has been provided.

[1]  P. V. van Ooijen,et al.  Does the aortic annulus undergo conformational change throughout the cardiac cycle? A systematic review. , 2015, European heart journal cardiovascular Imaging.

[2]  David Saloner,et al.  Ascending thoracic aortic aneurysm wall stress analysis using patient-specific finite element modeling of in vivo magnetic resonance imaging. , 2014, Interactive cardiovascular and thoracic surgery.

[3]  K. J. Grande,et al.  Stress Variations in the Human Aortic Root and Valve: The Role of Anatomic Asymmetry , 1998, Annals of Biomedical Engineering.

[4]  M. Maganti,et al.  Aortic root aneurysm: principles of repair and long-term follow-up. , 2010, The Journal of thoracic and cardiovascular surgery.

[5]  Peter Johansen,et al.  What forces act on a flat rigid mitral annuloplasty ring? , 2008, The Journal of heart valve disease.

[6]  T. David,et al.  An aortic valve-sparing operation for patients with aortic incompetence and aneurysm of the ascending aorta. , 1992, The Journal of thoracic and cardiovascular surgery.

[7]  P K Paulsen,et al.  What force can the myocardium generate on a prosthetic mitral valve ring? An animal experimental study. , 1994, The Journal of heart valve disease.

[8]  W. Nichols,et al.  McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles , 1998 .

[9]  M. Yacoub,et al.  Remodeling of the aortic valve anulus. , 1993, The Journal of thoracic and cardiovascular surgery.

[10]  Ajit P Yoganathan,et al.  Saddle-Shaped Mitral Valve Annuloplasty Rings Experience Lower Forces Compared With Flat Rings , 2008, Circulation.

[11]  J. B. Askov,et al.  In-plane Tricuspid Valve Force Measurements: Development of a Strain Gauge Instrumented Annuloplasty Ring , 2013 .

[12]  T Treasure,et al.  Effects of aortic root motion on wall stress in the Marfan aorta before and after personalised aortic root support (PEARS) surgery. , 2016, Journal of biomechanics.

[13]  T. David Aortic Valve Sparing Operations: A Review , 2012, The Korean journal of thoracic and cardiovascular surgery.

[14]  Khee Hiang Lim,et al.  Forces at single point attached commissures (SPAC) in pericardial aortic valve prosthesis. , 2006, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[15]  Susan Armstrong,et al.  Aortic valve-sparing operations in patients with aneurysms of the aortic root or ascending aorta. , 2002, The Annals of thoracic surgery.

[16]  M. Jensen,et al.  Simultaneous in- and out-of-plane Mitral Valve Annular Force Measurements , 2015, Cardiovascular Engineering and Technology.