Micromixing efficiency of a novel rotor–stator reactor

Abstract The importance of inlet region of rotating packed bed (RPB) was confirmed recently. This enlightened us to design another novel reactor, named rotor–stator reactor (RSR), which has multiple inlet regions along radial direction. The micromixing efficiency of RSR was studied by adopting the iodide–iodate reaction as working system. The effects of operating conditions (e.g. rotor speed and reagent concentration) on micromixing efficiency (characterized by segregation index XS) were investigated. In addition, the effects of different rotor–stator combinations as well as the amount of rotor- and stator-ring on micromixing efficiency were also considered. Based on the incorporation model, the micromixing time of RSR was estimated to reach about 10−5 s, which is less than that of rotating packed bed (about 10−4 s).

[1]  Gueray Tosun A study of micromixing in tee mixers , 1987 .

[2]  Duu-Jong Lee,et al.  Micromixing efficiency in static mixer , 2001 .

[3]  A. Wilhelm,et al.  Effects of ultrasound on micromixing in flow cell , 2000 .

[4]  Ryszard Pohorecki,et al.  Turbulent micromixing in chemical reactors - a review * , 1995 .

[5]  Fen Guo,et al.  Synthesis of Nanoparticles with Novel Technology: High-Gravity Reactive Precipitation , 2000 .

[6]  Duu-Jong Lee,et al.  Micromixing Effects in Aerated Stirred Tank , 1997 .

[7]  James R. Fair,et al.  Distillation Studies in a High-Gravity Contactor , 1996 .

[8]  J. R. Bourne,et al.  Rotor-stator mixers for rapid micromixing , 1986 .

[9]  Chia-Chang Lin,et al.  Ozone oxidation in a rotating packed bed , 2003 .

[10]  Laurent Falk,et al.  A new parallel competing reaction system for assessing micromixing efficiency—Experimental approach , 1996 .

[11]  Lei Shao,et al.  Synthesis of nano-fibers of aluminum hydroxide in novel rotating packed bed reactor , 2003 .

[12]  Laurent Falk,et al.  A new parallel competing reaction system for assessing micromixing efficiency—Determination of micromixing time by a simple mixing model , 1996 .

[13]  Jianfeng Chen,et al.  Micromixing Efficiency in a Rotating Packed Bed: Experiments and Simulation , 2005 .

[14]  L. Falk,et al.  Characterisation of micromixing efficiency by the iodide–iodate reaction system. Part I: experimental procedure , 2000 .

[15]  Lei Shao,et al.  Preparation of TiO2 nanoparticles by a rotating packed bed reactor , 2003 .

[16]  John R. Bourne,et al.  Fast reactions in rotor-stator mixers of different size , 1992 .

[17]  J. Villermaux,et al.  Characterisation of micromixing efficiency by the iodide–iodate reaction system. Part II: kinetic study , 2000 .

[18]  Duu-Jong Lee,et al.  Micromixing effects in a Couette flow reactor , 1999 .

[19]  Chia-Chang Lin,et al.  Removal of carbon dioxide by absorption in a rotating packed bed , 2003 .