Set‐valued observer‐based active fault‐tolerant model predictive control

Summary This paper proposes an integrated actuator and sensor active fault-tolerant model predictive control scheme. In this scheme, fault detection is implemented by using a set-valued observer, fault isolation (FI) is performed by set manipulations, and fault-tolerant control is carried out through the design of a robust model predictive control law. In this paper, a set-valued observer is used to passively complete the fault detection task, while FI is actively performed by making use of the constraint-handling capability of robust model predictive control. The set-valued observer is chosen to implement fault detection and isolation (FDI) because of its simple mathematical structure that is not affected by the type of faults such as sensor, actuator, and system-structural faults. This means that only one set-valued observer is needed to monitor all considered actuator and sensor statuses (health and fault) and to carry out the fault detection and isolation task instead of using a bank of observers (each observer matching a health/fault status). Furthermore, in the proposed scheme, the advantage of robust model predictive control is that it can effectively deal with system constraints, disturbances, and noises and allow to implement an active FI strategy, which can improve FI sensitivity when compared with the passive FI methods. Finally, a case study based on the well-known two-tank system is used to illustrate the effectiveness of the proposed fault-tolerant model predictive control scheme. Copyright © 2016 John Wiley & Sons, Ltd.

[1]  Alberto Bemporad,et al.  Predictive Control for Linear and Hybrid Systems , 2017 .

[2]  Maria M. Seron,et al.  Robust MPC design for fault tolerance of constrained multisensor linear systems , 2010, 2010 Conference on Control and Fault-Tolerant Systems (SysTol).

[3]  Giorgio Battistelli,et al.  Active mode observation of switching systems based on set‐valued estimation of the continuous state , 2009 .

[4]  Didier Dumur,et al.  Zonotope-based set-membership estimation for Multi-Output uncertain systems , 2013, 2013 IEEE International Symposium on Intelligent Control (ISIC).

[5]  Thomas Steffen,et al.  Control Reconfiguration of Dynamical Systems: Linear Approaches and Structural Tests , 2005 .

[6]  J. Löfberg Minimax approaches to robust model predictive control , 2003 .

[7]  Richard D. Braatz,et al.  Switched model predictive control of switched linear systems: Feasibility, stability and robustness , 2016, Autom..

[8]  Youmin Zhang,et al.  Bibliographical review on reconfigurable fault-tolerant control systems , 2003, Annu. Rev. Control..

[9]  José A. De Doná,et al.  Actuator fault tolerant multi-controller scheme using set separation based diagnosis , 2010, Int. J. Control.

[10]  Eduardo F. Camacho,et al.  Guaranteed state estimation by zonotopes , 2005, Autom..

[11]  José A. De Doná,et al.  Integrated sensor and actuator fault-tolerant control , 2013, Int. J. Control.

[12]  Richard D. Braatz,et al.  Fault-tolerant model predictive control with active fault isolation , 2013, 2013 Conference on Control and Fault-Tolerant Systems (SysTol).

[13]  Richard D. Braatz,et al.  Input design for guaranteed fault diagnosis using zonotopes , 2014, Autom..

[14]  Xiaoke Yang,et al.  Fault-tolerant model predictive control of a wind turbine benchmark , 2012 .

[15]  Thomas Lombaerts,et al.  Fault-tolerant control using dynamic inversion and model-predictive control applied to an aerospace benchmark ⋆ , 2008 .

[16]  Lin Li,et al.  FAULT-TOLERANT CONTROL FOR CONSTRAINED LINEAR SYSTEMS BASED ON MPC AND FDI , 2008 .

[17]  Vicenç Puig,et al.  Fault Diagnosis of Wind Turbines using a Set-membership Approach , 2011 .

[18]  Hernan Haimovich,et al.  Integration of invariant‐set‐based FDI with varying sampling rate virtual actuator and controller , 2016 .

[19]  ZhangLixian,et al.  Switched model predictive control of switched linear systems , 2016 .

[20]  Carlos Silvestre,et al.  Fault Detection and Isolation of LTV systems using Set-Valued Observers , 2010, 49th IEEE Conference on Decision and Control (CDC).

[21]  S. Joe Qin,et al.  A survey of industrial model predictive control technology , 2003 .

[22]  Vicenç Puig,et al.  Actuator-fault detection and isolation based on set-theoretic approaches , 2014 .

[23]  María M. Seron,et al.  A systematic method to obtain ultimate bounds for perturbed systems , 2007, Int. J. Control.

[24]  N. E. Wu,et al.  Concepts and methods in fault-tolerant control , 2001, Proceedings of the 2001 American Control Conference. (Cat. No.01CH37148).

[25]  Vicenç Puig,et al.  Sensor-fault tolerance using robust MPC with set-based state estimation and active fault isolation , 2014, 53rd IEEE Conference on Decision and Control.

[26]  Vicenç Puig,et al.  Set-theoretic methods in robust detection and isolation of sensor faults , 2015, Int. J. Syst. Sci..

[27]  Sorin Olaru,et al.  Positive invariant sets for fault tolerant multisensor control schemes , 2008 .

[28]  Francesco Tedesco,et al.  Actuator fault tolerant control: A set-theoretic approach , 2012, 2012 IEEE 51st IEEE Conference on Decision and Control (CDC).