Integrated single-photon emission computed tomography and computed tomography coronary angiography for the assessment of hemodynamically significant coronary artery lesions.

OBJECTIVES The purpose of this study was to assess the physiologic significance of coronary artery lesions with an integrated single-photon emission computed tomography (SPECT) and computed tomography coronary angiography (CTCA) device. BACKGROUND Myocardial perfusion imaging (MPI) with SPECT is of value for assessing the physiologic significance of coronary lesions. Computed tomography coronary angiography is a new technique to noninvasively detect coronary stenosis, with high sensitivity and negative predictive value (NPV) but lower specificity and positive predictive value (PPV). The experimental SPECT/CTCA hybrid imaging device (Infinia gamma camera and LightSpeed16 CT, General Electric, Milwaukee, Wisconsin) enables concurrent assessment of coronary anatomy and myocardial perfusion. METHODS Fifty-six patients with angina pectoris underwent single-session SPECT-MPI and CTCA with the hybrid device and coronary angiography (CA) within 4 weeks. The ability of fused SPECT/CTCA images to diagnose physiologically significant lesions showing >50% stenosis and reversible perfusion defects in the same territory was determined and compared with CTCA stand-alone. RESULTS Of a total of 224 coronary segments in 56 patients, 12 patients and 54 segments (23%) were excluded from further analysis of CTCA. Overall, 170 coronary segments were evaluated. The sensitivity, specificity, PPV, and NPV of CTCA were 96%, 63%, 31%, and 99%, respectively, as compared with 96%, 95%, 77%, and 99%, respectively, for SPECT/CTCA. CONCLUSIONS Hybrid SPECT/CTCA imaging results in improved specificity and PPV to detect hemodynamically significant coronary lesions in patients with chest pain. Single-photon emission computed tomography/CTCA might play a potentially important role in the noninvasive diagnosis of coronary artery disease and introduce an objective decision-making tool for assessing the need for interventions in each occluded vessel.

[1]  Cyrill Burger,et al.  Integrated PET/CT for the assessment of coronary artery disease: a feasibility study. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  Russell D Folks,et al.  Three-dimensional fusion of coronary arteries with myocardial perfusion distributions: clinical validation. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  K. Lee,et al.  Recurrent ischemia without warning. Analysis of risk factors for in-hospital ischemic events following successful thrombolysis with intravenous tissue plasminogen activator. , 1989, Circulation.

[4]  Y. Wang,et al.  Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. , 1999, Radiology.

[5]  E. Braunwald Heart Disease: A Textbook of Cardiovascular Medicine , 1992, Annals of Internal Medicine.

[6]  Colin J. Martin,et al.  Radiation Dose and Image Quality , 2008 .

[7]  W. Edwards,et al.  Arterial calcification and not lumen stenosis is highly correlated with atherosclerotic plaque burden in humans: a histologic study of 723 coronary artery segments using nondecalcifying methodology. , 1998, Journal of the American College of Cardiology.

[8]  Udo Hoffmann,et al.  Predictive Value of 16-Slice Multidetector Spiral Computed Tomography to Detect Significant Obstructive Coronary Artery Disease in Patients at High Risk for Coronary Artery Disease: Patient- Versus Segment-Based Analysis , 2004, Circulation.

[9]  E. Depuey,et al.  Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease. , 1988, Circulation.

[10]  Jeroen J. Bax,et al.  Feasibility of assessment of coronary stent patency using 16-slice computed tomography. , 2004, The American journal of cardiology.

[11]  J. Rumberger,et al.  Coronary artery calcium area by electron-beam computed tomography and coronary atherosclerotic plaque area. A histopathologic correlative study. , 1995, Circulation.

[12]  W. Bautz,et al.  Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar Reconstruction , 2003, Circulation.

[13]  Jeroen J. Bax,et al.  Meta-analysis of comparative diagnostic performance of magnetic resonance imaging and multislice computed tomography for noninvasive coronary angiography. , 2006, American heart journal.

[14]  E. Topol,et al.  Our preoccupation with coronary luminology. The dissociation between clinical and angiographic findings in ischemic heart disease. , 1995, Circulation.

[15]  M. Verani,et al.  Quantitative exercise thallium-201 single photon emission computed tomography for the enhanced diagnosis of ischemic heart disease. , 1990, Journal of the American College of Cardiology.

[16]  U. Joseph Schoepf CT of the Heart , 2005 .

[17]  P. Serruys,et al.  Large thrombus entrapped in a patent foramen ovale of the atrial septum, which apparently “disappeared” without embolic events , 2002, Heart.

[18]  G. Beller,et al.  Prediction of cardiac events after uncomplicated myocardial infarction: a prospective study comparing predischarge exercise thallium-201 scintigraphy and coronary angiography. , 1983, Circulation.

[19]  Gabriel P. Krestin,et al.  High-Resolution Spiral Computed Tomography Coronary Angiography in Patients Referred for Diagnostic Conventional Coronary Angiography , 2005, Circulation.

[20]  Filippo Cademartiri,et al.  CT Angiography for the Detection of Coronary Artery Stenosis , 2005 .

[21]  M. Reiser,et al.  Comparison of spiral multidetector CT angiography and myocardial perfusion imaging in the noninvasive detection of functionally relevant coronary artery lesions: first clinical experiences. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[22]  Gabriel P. Krestin,et al.  Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris , 2006, European Radiology.

[23]  M. Prokop,et al.  Spiral and multislice computed tomography of the body , 2003 .

[24]  M F Reiser,et al.  ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. , 2001, Radiology.

[25]  Michael Grass,et al.  Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. , 2005, Radiology.

[26]  Matthijs Oudkerk,et al.  Coronary angiography with multi-slice computed tomography , 2001, The Lancet.

[27]  K. Lee,et al.  A randomized trial of immediate versus delayed elective angioplasty after intravenous tissue plasminogen activator in acute myocardial infarction. , 1987, The New England journal of medicine.

[28]  Jeroen J. Bax,et al.  Information Statement - Approved November 2004 , 2005 .

[29]  J. Kennedy Complications associated with cardiac catheterization and angiography. , 1982, Catheterization and cardiovascular diagnosis.

[30]  Paul Schoenhagen,et al.  Effect of recombinant ApoA-I Milano on coronary atherosclerosis in patients with acute coronary syndromes: a randomized controlled trial. , 2003, JAMA.

[31]  P. Serruys,et al.  Usefulness of multislice computed tomography for detecting obstructive coronary artery disease. , 2002, The American journal of cardiology.

[32]  G. Taylor,et al.  Quantitative thallium-201 exercise scintigraphy for detection of coronary artery disease. , 1981, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.