Potentiometric urea biosensor utilizing nanobiocomposite of chitosan-iron oxide magnetic nanoparticles

The iron oxide (Fe3O4) magnetic nanoparticles have been fabricated through a simple, cheap and reproducible approach. Scanning electron microscope, x-rays powder diffraction of the fabricated nanoparticles. Furthermore, the fabrication of potentiometric urea biosensor is carried out through drop casting the initially prepared isopropanol and chitosan solution, containing Fe3O4 nanoparticles, on the glass fiber filter with a diameter of 2 cm and a copper wire (of thickness −500 μm) has been utilized to extract the voltage signal from the functionalized nanoparticles. The functionalization of surface of the Fe3O4 nanoparticles is obtained by the electrostatically immobilization of urease onto the nanobiocomposite of the chitosan- Fe3O4 in order to enhance the sensitivity, specificity, stability and reusability of urea biosensor. Electrochemical detection procedure has been adopted to measure the potentiometric response over the wide logarithmic concentration range of the 0.1 mM to 80 mM. The Fe3O4 nanoparticles based urea biosensor depicts good sensitivity with ~42 mV per decade at room temperature. Durability of the biosensor could be considerably enhanced by applying a thin layer of the nafion. In addition, the reasonably stable output response of the biosensor has been found to be around 12 sec.

[1]  Werner Stumm,et al.  Fresh Water and Ocean. (Book Reviews: Aquatic Chemistry. An Introduction Emphasizing Chemical Equilibria in Natural Waters) , 1982 .

[2]  P. Solanki,et al.  Zinc oxide nanoparticles-chitosan composite film for cholesterol biosensor. , 2008, Analytica chimica acta.

[3]  X. W. Sun,et al.  Enzymatic glucose biosensor based on ZnO nanorod array grown by hydrothermal decomposition , 2006 .

[4]  George R. Helz,et al.  Aquatic chemistry—An introduction emphasizing chemical equilibria in natural waters: By Werner Stumm and James J. Morgan. Second Edition, John Wiley and Sons, 1981, 780 pp. $45.00 (cloth), $27.50 (paper) , 1982 .

[5]  Sheng-Fu Wang,et al.  A novel amperometric immunosensor based on Fe3O4 magnetic nanoparticles/chitosan composite film for determination of ferritin , 2007, Analytical and bioanalytical chemistry.

[6]  Guodong Liu,et al.  Amperometric tyrosinase biosensor based on Fe3O4 nanoparticles-chitosan nanocomposite. , 2008, Biosensors & bioelectronics.

[7]  J. Alam,et al.  Iron oxide nanoparticles-chitosan composite based glucose biosensor. , 2008, Biosensors & bioelectronics.

[8]  Jing‐Juan Xu,et al.  Fabrication, characterization of Fe3O4 multilayer film and its application in promoting direct electron transfer of hemoglobin , 2006 .

[9]  P. Solanki,et al.  Sol–gel derived nanoporous cerium oxide film for application to cholesterol biosensor , 2008 .

[10]  Erkang Wang,et al.  Fe3O4 magnetic nanoparticles as peroxidase mimetics and their applications in H2O2 and glucose detection. , 2008, Analytical chemistry.

[11]  N. Jaffrezic‐Renault,et al.  Urea biosensors based on immobilization of urease into two oppositely charged clays (laponite and Zn-Al layered double hydroxides). , 2002, Analytical chemistry.

[12]  N. Hu,et al.  Direct electron transfer between hemoglobin and pyrolytic graphite electrodes enhanced by Fe(3)O(4) nanoparticles in their layer-by-layer self-assembly films. , 2006, Biophysical chemistry.

[13]  N. Jaffrezic‐Renault,et al.  Comparative study between organic and inorganic entrapment matrices for urease biosensor development , 2007 .

[14]  B. D. Malhotra,et al.  Cholesterol biosensor based on rf sputtered zinc oxide nanoporous thin film , 2007 .

[15]  H. Mu,et al.  Nanobiotechnology , 2013, BioMed Research International.

[16]  R. M. Pytkowicz Book Review: Aquatic chemistry: an introduction emphasizing chemical equilibria in natural waters. WERNER STUMM and JAMES J. MORGAN, 1970. Wiley-Interscience, 583 pp. Illus. , 1971 .

[17]  Bansi D. Malhotra,et al.  Sol-gel derived nanostructured cerium oxide film for glucose sensor , 2008 .

[18]  P. Solanki,et al.  Iron oxide-chitosan nanobiocomposite for urea sensor , 2009 .

[19]  J. Irudayaraj,et al.  Examination of Cholesterol oxidase attachment to magnetic nanoparticles , 2005, Journal of nanobiotechnology.

[20]  Sultan Kermally From the conference series , 1995 .

[21]  Keiichi Kaneto,et al.  An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film. , 2005, Biomaterials.

[22]  Rahul Singhal,et al.  Immobilization of urease on poly(N-vinyl carbazole)/stearic acid Langmuir-Blodgett films for application to urea biosensor. , 2002, Biosensors & bioelectronics.

[23]  P. Solanki,et al.  Chitosan-iron oxide nanobiocomposite based immunosensor for ochratoxin-A , 2008 .

[24]  Ajeet Kaushik,et al.  Zinc oxide-chitosan nanobiocomposite for urea sensor , 2008 .

[25]  Xiangqin Cui,et al.  Sensors and Actuators B , 2003 .

[26]  Zeev Rosenzweig,et al.  Glucose oxidase–magnetite nanoparticle bioconjugate for glucose sensing , 2004, Analytical and bioanalytical chemistry.