Web-bonded FRPs for relocation of plastic hinges away from the column face in exterior RC joints

Abstract In an RC building subjected to lateral loads, the beam–column joints constitute one of the critical regions. In existing frames, which were not adequately designed, a practical way of controlling plastic hinging and implement the strong-column weak-beam concept is through the use of a web-bonded FRP retrofitting system. This paper presents the results of an experimental and numerical study carried out in order to evaluate the ability of CFRP sheets in preventing the plastic hinge formation at the face of the column in exterior RC joints. Seven scaled-down RC exterior joints of a typical Ordinary Moment Resisting Frame are tested under moderately monotonic/cyclic loads. Two specimens are used as control while the other five are CFRP-strengthened/repaired of different lengths and thicknesses. The results show that carbon fibre sheets can effectively relocate the plastic hinge away from the face of the column. Non-linear numerical results using ANSYS are also presented and discussed.

[1]  Riyad S Aboutaha,et al.  Cyclic Response of Exterior Reinforced Concrete Beam-Column Joints Reinforced with Headed Bars-Experimental Investigation , 2003 .

[2]  Robert Park,et al.  Evaluation of ductility of structures and structural assemblages from laboratory testing , 1989 .

[3]  Scott T Smith,et al.  CFRP-retrofitted RC exterior beam-column connections under cyclic loads , 2004 .

[4]  T. Paulay,et al.  Reinforced Concrete Structures , 1975 .

[5]  J. Wight,et al.  MOVING BEAM PLASTIC HINGING ZONES FOR EARTHQUAKE RESISTANT DESIGN OF R/C BUILDINGS. , 1986 .

[6]  K. G. Satyanarayana Developments in composites: advanced, infrastructural, natural and nano-composites , 2007 .

[7]  Matthew B. Blaschko,et al.  Externally bonded FRP reinforcement for RC structures , 2001 .

[8]  Hamid R. Ronagh,et al.  Numerical modelling of FRP strengthened RC beam-column joints , 2009 .

[9]  C. Karayannis,et al.  Strengthening and rehabilitation of RC beam–column joints using carbon‐FRP jacketing and epoxy resin injection , 2008 .

[10]  Y. Goto,et al.  Influence of Transverse Joint and Beam Reinforcement and Relocation of Plastic Hinge Region onBeam Column Joint Stiffness Deterioration , 1991, SP-123: Design of Beam-Column Joints for Seismic Resistance.

[11]  Scott T Smith,et al.  A review of FRP- strengthened RC beam-column connections , 2006 .

[12]  Deric J. Oehlers Strengthening of concrete structures with FRP and steel plates – Australian guideline , 2006 .

[13]  T. Paulay,et al.  Seismic Design of Reinforced Concrete and Masonry Buildings , 1992 .

[14]  S S Mahini,et al.  FLEXURAL REPAIR OF RC EXTERIOR BEAM- COLUMN JOINTS USING CFRP SHEET , 2004 .

[15]  S. S. Mahini,et al.  A NEW METHOD FOR IMPROVING DUCTILITY IN EXISTING RC ORDINARY MOMENT RESISTING FRAMES USING FRPS , 2007 .

[16]  Hamid R. Ronagh,et al.  Strength and ductility of FRP web-bonded RC beams for the assessment of retrofitted beam–column joints , 2010 .