Low-dose CT with tin filter combined with iterative metal artefact reduction for guiding lung biopsy.

Background Computed tomography (CT) is currently the imaging modality of choice for guiding pulmonary percutaneous procedures. The use of a tin filter allows low-energy photons to be absorbed which contribute little to image quality but increases the radiation dose that a patient receives. Iterative metal artefact reduction (iMAR) was developed to diminish metal artefacts. This study investigated the impact of using tin filtration combined with an iMAR algorithm on dose reduction and image quality in CT-guided lung biopsy. Methods Ninety-nine consecutive patients undergoing CT-guided lung biopsy were randomly assigned to routine-dose CT protocols (groups A and B; without and with iMAR, respectively) or tin filter CT protocols (groups C and D; without or with iMAR, respectively). Subjective image quality was analysed using a 5-point Likert scale. Objective image quality was assessed, and the noise, contrast-to-noise ratio, and figure of merit were compared among the four groups. Metal artefacts were quantified using CT number reduction and metal diameter blurring. The radiation doses, diagnostic performance, and complication rates were also estimated. Results The subjective image quality of the two scan types was compared. Images with iMAR reconstruction were superior to those without iMAR reconstruction (group A: 3.49±0.65 vs. group B: 4.63±0.57; P<0.001, and group C: 3.88±0.66 vs. group D: 4.82±0.39; P<0.001). Images taken with a tin filter were found to have a significantly higher figure-of-merit than those taken without a tin filter (group A: 14,041±7,230 vs. group C: 21,866±10,656; P=0.001, and group B: 13,836±6,849 vs. group D: 21,639±9,964; P=0.001). In terms of metal artefact reduction, tin filtration combined with iMAR showed the lowest CT number reduction (116.62±103.48 HU) and metal diameter blurring (0.85±0.30) among the protocols. The effective radiation dose in the tin filter groups was 73.2% lower than that in the routine-dose groups. The complication rate and diagnostic performance (sensitivity, specificity, and overall accuracy) did not differ significantly between the tin filter and routine-dose groups (all P>0.05). Conclusions Tin filtration combined with an iMAR algorithm may reduce the radiation dose compared to the routine-dose CT protocol, while maintaining comparable diagnostic accuracy and image quality and producing fewer metal artefacts.

[1]  P. Claret,et al.  Ultra-low-dose chest CT performance for the detection of viral pneumonia patterns during the COVID-19 outbreak period: a monocentric experience. , 2021, Quantitative imaging in medicine and surgery.

[2]  Sang Min Lee,et al.  2020 Clinical Practice Guideline for Percutaneous Transthoracic Needle Biopsy of Pulmonary Lesions: A Consensus Statement and Recommendations of the Korean Society of Thoracic Radiology , 2020, Korean journal of radiology.

[3]  Xianlong Wang,et al.  Risk factors associated with pulmonary hemorrhage and hemoptysis following percutaneous CT-guided transthoracic lung core needle biopsy: a retrospective study of 1,090 cases. , 2020, Quantitative imaging in medicine and surgery.

[4]  C. Zimmer,et al.  Radiation dose reduction for CT-guided intrathecal nusinersen administration in adult patients with spinal muscular atrophy , 2020, Scientific Reports.

[5]  Yan Wang,et al.  Chest CT screening in patients with overweight or obesity using spectral shaping at 150 kVp: compared with 120 kVp protocol and spectral shaping at 100 kVp protocol , 2020, Japanese Journal of Radiology.

[6]  M. Lindqvist,et al.  First experiences of a low-dose protocol for CT-guided musculoskeletal biopsies combining different radiation dose reduction techniques , 2020, Acta radiologica.

[7]  J. Remy,et al.  Pediatric chest computed tomography at 100 kVp with tin filtration: comparison of image quality with 70-kVp imaging at comparable radiation dose , 2019, Pediatric Radiology.

[8]  Yu-Fei Fu,et al.  Computed tomography–guided lung biopsy: a randomized controlled trial of low-dose versus standard-dose protocol , 2019, European Radiology.

[9]  S. Wildermuth,et al.  Lung cancer screening with submillisievert chest CT: Potential pitfalls of pulmonary findings in different readers with various experience levels. , 2019, European journal of radiology.

[10]  Bo Liu,et al.  Ultralow dose computed tomography protocol for hook‐wire localization of solitary pulmonary nodules prior to video‐assisted thoracoscopic surgery , 2019, Thoracic cancer.

[11]  Wei Zhou,et al.  Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration , 2019, Investigative radiology.

[12]  C. Mistretta,et al.  Ultra-Low Radiation Dose CT Fluoroscopy for Percutaneous Interventions: A Porcine Feasibility Study. , 2019, Radiology.

[13]  Thuy Duong Do,et al.  The value of iterative metal artifact reduction algorithms during antenna positioning for CT-guided microwave ablation , 2019, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[14]  A. Jemal,et al.  Global cancer statistics 2018: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries , 2018, CA: a cancer journal for clinicians.

[15]  Sang Min Lee,et al.  Diagnostic performance of CT-guided percutaneous transthoracic core needle biopsy using low tube voltage (100 kVp): comparison with conventional tube voltage (120 kVp) , 2018, Acta radiologica.

[16]  A. Wetter,et al.  Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses , 2018, European Radiology.

[17]  C. McCollough,et al.  CT Dental Artifact: Comparison of an Iterative Metal Artifact Reduction Technique with Weighted Filtered Back-Projection , 2017, Acta radiologica open.

[18]  M. Sedlmair,et al.  Iterative metal artefact reduction (MAR) in postsurgical chest CT: comparison of three iMAR-algorithms. , 2017, The British journal of radiology.

[19]  J. Caspers,et al.  Iterative metal artefact reduction in CT: can dedicated algorithms improve image quality after spinal instrumentation? , 2017, Clinical radiology.

[20]  S. Wildermuth,et al.  Ultralow dose CT for pulmonary nodule detection with chest x-ray equivalent dose – a prospective intra-individual comparative study , 2017, European Radiology.

[21]  T. Vogl,et al.  Low-dose abdominal computed tomography for detection of urinary stone disease - Impact of additional spectral shaping of the X-ray beam on image quality and dose parameters. , 2016, European journal of radiology.

[22]  M. Hellmich,et al.  Radiation Dose Reduction in Computed Tomography-Guided Lung Interventions using an Iterative Reconstruction Technique , 2015, Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren.

[23]  Francesco C Stingo,et al.  An evaluation of three commercially available metal artifact reduction methods for CT imaging , 2015, Physics in medicine and biology.

[24]  Thomas Flohr,et al.  Low-dose CT of the lung: potential value of iterative reconstructions , 2012, European Radiology.

[25]  A. Stadler,et al.  CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: accuracy, complications and radiation dose. , 2012, European journal of radiology.

[26]  M. Maher,et al.  CT-guided percutaneous needle biopsy of the chest: preprocedural evaluation and technique. , 2011, AJR. American journal of roentgenology.

[27]  E. Paulson,et al.  CT fluoroscopy--guided interventional procedures: techniques and radiation dose to radiologists. , 2001, Radiology.

[28]  A L Oberg,et al.  Benefits and safety of CT fluoroscopy in interventional radiologic procedures. , 2001, Radiology.

[29]  Report on Amendments during 1956 to the Recommendations of the International Commission on Radiological Protection (ICRP) , 1959 .

[30]  Bo Liu,et al.  Efficacy and Radiation Exposure of Ultra-Low-Dose Chest CT at 100 kVp with Tin Filtration in CT-Guided Percutaneous Core Needle Biopsy for Small Pulmonary Lesions Using a Third-Generation Dual-Source CT Scanner. , 2019, Journal of vascular and interventional radiology : JVIR.

[31]  V. Yaghmai,et al.  Application of Iterative Metal Artifact Reduction Algorithm to CT Urography for Patients With Hip Prostheses. , 2019, AJR. American journal of roentgenology.

[32]  Gerald Antoch,et al.  Metal Artifact Reduction in Computed Tomography After Deep Brain Stimulation Electrode Placement Using Iterative Reconstructions , 2017, Investigative radiology.

[33]  M. Kayan,et al.  CT-guided transthoracic biopsy: histopathologic results and complication rates. , 2015, Diagnostic and interventional radiology.

[34]  Quantitative Imaging in Medicine and Surgery , 2013 .

[35]  P. Mountford,et al.  Recommendations of the International Commission on Radiological Protection (ICRP) 1990 , 2004, European Journal of Nuclear Medicine.